Boomer-III User Manual & Integrator’s Guide________________________________ Appendix A - NCL INTERFACE
BM310012WT04
91
Copyright Wavenet Technology © October 2003
Parameter length :
0x0001 (“Byte3Byte4”)
Parameter contents :
One unsigned byte (“Byte5”) indicating the Power
Save mode as follow:
ASCII ‘0’ :
EXPRESS (Disabled
Power Save or “full awake” mode).
ASCII ‘1’ :
MAXIMUM (4 windows).
ASCII ‘2’ :
AVERAGE (8 windows).
ASCII ‘3’ :
MINIMUM (16 windows).
Parameter name:
WN_PROFILE
Parameter number :
0x6600 (“Byte1Byte2”) (ASCII 0x66 = ‘f’)
Parameter length :
0x0001 (“Byte3Byte4”)
Parameter contents:
One unsigned byte with the number of the new
active profile.
Parameter name:
WN_MSG_RX_NOTIF_TMR
Parameter number :
0x6E00 (“Byte1Byte2”) (ASCII 0x6E = ‘n’)
Parameter length :
0x0002 (“Byte3Byte4”)
Parameter contents:
One unsigned word (2 bytes) containing the
number of milliseconds between message
notifications to the Palm. The maximum setting is
65 seconds (65000 milliseconds).