SAFETY

DEFINITIONS

CHASSIS GROUND Symbol

CAUTION:  A condition that has the potential to 

cause damage to property or instrument.

WARNING:  A condition that has the potential to 

cause bodily harm or death.

GENERAL

•  Observe all Cautions and Warnings both in the User 

Guide and on the instrument.

• 

Use the QCL instrument as specified in this guide or the 

protection provided by this instrument may be impaired 

and the warranty will be voided.

•  Use good laser safety practices when using the QCL 

instrument.

•  Before proceeding, it is critical that you take precautions 

to prevent electrostatic discharge (ESD) damage to your 

laser. 

•  Locking the instrument with the keyswitch disables the 

output current. The key can only be removed when in the 

LOCK position.

POWER CORDS

•  This equipment is grounded through the AC power cord 

grounding conductor.

•  Use only the earth-grounded power cords that are 

recommended in this user guide.

•  Route power cords and other cables so that they cannot 

be damaged.

•  Position the QCL instrument in a location that makes it 

easy to quickly disconnect the power cord.

• 

To avoid fire hazard, use only the specified power cords 

with the correct grounding, voltage, and current ratings.

FUSES

•  Disconnect the power to the QCL instrument before 

changing the fuses.

•  To prevent damage to the QCL instrument when replacing 

fuses, locate and correct the problem that caused the fuse 

to blow before re-applying power.

• 

To avoid fire hazard, use only the specified fuse with the 

correct type number, voltage, and current ratings, and use 

only the recommended replacement parts.

CAUTIONS

The QCL instrument has no user-serviceable parts. 

Other than the fuses, the QCL instrument is not 

designed to be maintained by the user nor does it 

contain any parts that can be repaired by the user. 

All maintenance and repairs must be performed by 

Wavelength or the warranty will be void. 
Use a soft cloth to remove dust from the QCL 

instrument. Do not expose the QCL instrument to 

any liquids, sprays, or solvents. To avoid electrical 

shock, unplug the power cord before cleaning the 

instrument.
Before connecting to the power source, make sure 

the correct cables and voltage for your area are 

set. The voltage selection is available on the back 

of the instrument. See the Quick Start Guide for 

instructions on changing the voltage.

WARNINGS

Position the QCL instrument so that access to the 

Main  Power  On/Off  switch  on  the  back  panel  is 

easily accessed.
Do not use the QCL instrument if there is evidence 

of damage from shipping; damaged equipment 

can  present  significant  safety  hazards.  If  you 

suspect the QCL instrument is damaged, contact 

Wavelength technical support before attempting to 

operate the instrument.
To avoid electrical shock, use the recommended 

earth-grounded power cables and properly earth-

grounded, 3-prong receptacles only. Failure to 

follow this precaution can result in severe injury.
To avoid injury, do not tell the engineers how to 

do their jobs. Let them muddle through until they 

decide to read the User Guide.

Содержание QCL500 LAB

Страница 1: ...t RCKMT LABDUAL 19 Double Unit Rack Mount Kit INTLK REPL KIT included with purchase Interlock Replacement Kit with BNC terminator and modified D SUB connector to override interlocks e Pb RoHS Complian...

Страница 2: ...ailable Powering your QCL with this patented1 driver gives you narrow linewidth stable center wavelength and repeatable scans INTUITIVE USER INTERFACE AND SUPERIOR SOFTWARE CONTROL With Wavelength s p...

Страница 3: ...ing power To avoid fire hazard use only the specified fuse with the correct type number voltage and current ratings and use only the recommended replacement parts CAUTIONS The QCL instrument has no us...

Страница 4: ...Then turn the drawer until the correct voltage label is at the top and replace it in the receptacle Press firmly to make sure the drawer is completely seated It should be flush with the receptacle Fig...

Страница 5: ...blue Limit Current value and rotate the Adjustment knob to change to the desired value The instrument will beep when set NOTE The Max Supply Voltage and Cable Resistance values can be ignored for now...

Страница 6: ...can source 250 mA 2 Alignment LED ground 3 QCL current enabled indicator 5 V TTL high disabled low ground enabled 4 QCL current enabled indicator ground 5 Not used 6 Analog setpoint monitor 7 Analog...

Страница 7: ...XTERNAL MODULATION MIN TYP MAX UNITS NOTES Modulation Bandwidth 2 3 MHz Sinewave Rise Fall Time 250 200 nsec To full scale Slew Rate 30 V sec Depth of Modulation 90 At 500 kHz External Modulation Inpu...

Страница 8: ...atts At idle no output to QCL load GENERAL SPECIFICATIONS VALUE NOTES Warm up Time 1 Hour Remote Interface USB Ethernet Warranty One 1 Year Safety Tested To IEC 61000 3 2 IEC 61000 3 3 IEC 61000 4 2 I...

Страница 9: ...rive current for the laser Over and under voltage protection circuits protect the driver and QCL if the power supply voltages fall outside of the acceptable operating range Over temperature protection...

Страница 10: ...cal earth ground 3 QCL SMA SMA connector alternate connection to QCL 4 QCL D SUB 9 Pin female D SUB connector 5 Monitors 9 Pin male D SUB connector 6 USB USB port connection between instrument and a c...

Страница 11: ...receptacle Press firmly to make sure the drawer is completely seated It should be flush with the receptacle Figure 12 Fuse Installation and Voltage Selector 5 Close the faceplate again pressing firml...

Страница 12: ...ument beeps and text returns to blue when values are set Touch again to cancel selection ICONS Icon color indicates current state Blue Screen is active Grey Screen is inactive touch icon to access tha...

Страница 13: ...aximum Internal Supply Voltage can be lowered to minimize internal instrument temperature or to act as a compliance voltage clamp on the QCL output current See Additional Technical Notes on page 20 fo...

Страница 14: ...n press the red Stop button to abort the scan Any data collected during the aborted scan is saved to the USB flash drive NOTES The step interval time is approximate In the scan files time intervals ar...

Страница 15: ...ernal modulation signal voltage see the next section for the transfer function and use the following equation VEXT_MOD ISETPOINT Transfer Function If the external modulation input causes the driver to...

Страница 16: ...TTL indicator If current to the QCL output is enabled the voltage between PIN 3 and PIN 4 on the MONITORS D SUB will be low It will be high if current is disabled USE THE TRIGGER SIGNAL A trigger sig...

Страница 17: ...rument experienced an internal fault See Error Messages on page 19 Switch the back panel power button off and then on again and turn the front panel power button on The internal temperature has reache...

Страница 18: ...hen actively operating in current limit the safety circuits add noise to the output If I run my QCL at about 5 of maximum output current the transfer function becomes non linear and I see distortion i...

Страница 19: ...instrument cannot drive current through the load Make sure the QCL SMA or Pins 5 9 of the QCL D SUB are connected A short circuit was detected at the load terminals Please verify the load and load co...

Страница 20: ...ge input and the current is still not compliance voltage limited the instrument is operating at its lowest voltage and the voltage limit cannot be reduced further USE PASSIVE AND ACTIVE INTERLOCKS The...

Страница 21: ...found at www teamwavelength com support software downloads 3 Extract the file on the flash drive It should contain the following files INSTALL INI QCLxx ABL IMG QCLxx APP IMG QCLxx INSTALL INI NOTE Q...

Страница 22: ...22 MECHANICAL SPECIFICATIONS 0 72 3 89 0 66 16 8 3 92 99 6 6 10 154 9 8 49 215 6 Dimensions are in inches mm Tolerance is 5 8 860 225 0 3 47 88 14 8 860 225 0 16 35 415 16 35 415 17 72 450 3 47 88 14...

Страница 23: ...patibility tested to IEC 61000 3 2 and IEC 61000 3 3 IEC 61000 4 2 IEC 61000 4 3 IEC 61000 4 4 IEC 61000 4 5 IEC 61000 4 6 and IEC 61000 4 8 European Council Directive 2014 35 EC 26 February 2014 on L...

Страница 24: ...tion contained in this document is subject to change without notice Wavelength will not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishi...

Отзывы: