background image

23

CE DECLARATION OF CONFORMITY

CONFORMING PRODUCTS

MODEL NUMBER

PRODUCT

QCL500 LAB

500 mA QCL Driver Laboratory Instrument

QCL1000 LAB

1000 mA QCL Driver Laboratory Instrument

QCL1500 LAB

1500 mA QCL Driver Laboratory Instrument

QCL2000 LAB

2000 mA QCL Driver Laboratory Instrument

DECLARATION

The undersigned hereby declares, on behalf of Wavelength Electronics, Inc. (Wavelength) of Bozeman, Montana, that the 

products listed in the table above, to which this Declaration applies, are in conformity with the provisions of:

APPLICABLE REGULATIONS

•  European Council Directive 2014/30/EC (26 February, 2014) on Electromagnetic Compatibility, tested to:

 

»

IEC 61000-3-2 and IEC 61000-3-3

 

»

IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, and IEC 61000-4-8

•  European Council Directive 2014/35/EC (26 February, 2014) on Low-Voltage Equipment Safety, tested to:

 

»

IEC 61010-1

•  European Council Directive 2015/863EU to amend Annex II to EU RoHS 2 (Directive 2011/65/EU) on Restriction of the 

use of certain hazardous substances in electrical and electronic equipment (recast) and the consolidated version of 24 

June 2015

•  Commission Delegated Directive (EU) 2016/585 of 12 February 2016 amending Annex IV to Directive 2011/65/EU

TECHNICAL FILE

The Technical Construction Files for the listed products, as required by this Declaration, are maintained at Wavelength 

corporate headquarters: 51 Evergreen Drive, Bozeman, Montana.  

 

8-Jul-16

 

Mary Johnson, CEO 

Date

Содержание QCL500 LAB

Страница 1: ...t RCKMT LABDUAL 19 Double Unit Rack Mount Kit INTLK REPL KIT included with purchase Interlock Replacement Kit with BNC terminator and modified D SUB connector to override interlocks e Pb RoHS Complian...

Страница 2: ...ailable Powering your QCL with this patented1 driver gives you narrow linewidth stable center wavelength and repeatable scans INTUITIVE USER INTERFACE AND SUPERIOR SOFTWARE CONTROL With Wavelength s p...

Страница 3: ...ing power To avoid fire hazard use only the specified fuse with the correct type number voltage and current ratings and use only the recommended replacement parts CAUTIONS The QCL instrument has no us...

Страница 4: ...Then turn the drawer until the correct voltage label is at the top and replace it in the receptacle Press firmly to make sure the drawer is completely seated It should be flush with the receptacle Fig...

Страница 5: ...blue Limit Current value and rotate the Adjustment knob to change to the desired value The instrument will beep when set NOTE The Max Supply Voltage and Cable Resistance values can be ignored for now...

Страница 6: ...can source 250 mA 2 Alignment LED ground 3 QCL current enabled indicator 5 V TTL high disabled low ground enabled 4 QCL current enabled indicator ground 5 Not used 6 Analog setpoint monitor 7 Analog...

Страница 7: ...XTERNAL MODULATION MIN TYP MAX UNITS NOTES Modulation Bandwidth 2 3 MHz Sinewave Rise Fall Time 250 200 nsec To full scale Slew Rate 30 V sec Depth of Modulation 90 At 500 kHz External Modulation Inpu...

Страница 8: ...atts At idle no output to QCL load GENERAL SPECIFICATIONS VALUE NOTES Warm up Time 1 Hour Remote Interface USB Ethernet Warranty One 1 Year Safety Tested To IEC 61000 3 2 IEC 61000 3 3 IEC 61000 4 2 I...

Страница 9: ...rive current for the laser Over and under voltage protection circuits protect the driver and QCL if the power supply voltages fall outside of the acceptable operating range Over temperature protection...

Страница 10: ...cal earth ground 3 QCL SMA SMA connector alternate connection to QCL 4 QCL D SUB 9 Pin female D SUB connector 5 Monitors 9 Pin male D SUB connector 6 USB USB port connection between instrument and a c...

Страница 11: ...receptacle Press firmly to make sure the drawer is completely seated It should be flush with the receptacle Figure 12 Fuse Installation and Voltage Selector 5 Close the faceplate again pressing firml...

Страница 12: ...ument beeps and text returns to blue when values are set Touch again to cancel selection ICONS Icon color indicates current state Blue Screen is active Grey Screen is inactive touch icon to access tha...

Страница 13: ...aximum Internal Supply Voltage can be lowered to minimize internal instrument temperature or to act as a compliance voltage clamp on the QCL output current See Additional Technical Notes on page 20 fo...

Страница 14: ...n press the red Stop button to abort the scan Any data collected during the aborted scan is saved to the USB flash drive NOTES The step interval time is approximate In the scan files time intervals ar...

Страница 15: ...ernal modulation signal voltage see the next section for the transfer function and use the following equation VEXT_MOD ISETPOINT Transfer Function If the external modulation input causes the driver to...

Страница 16: ...TTL indicator If current to the QCL output is enabled the voltage between PIN 3 and PIN 4 on the MONITORS D SUB will be low It will be high if current is disabled USE THE TRIGGER SIGNAL A trigger sig...

Страница 17: ...rument experienced an internal fault See Error Messages on page 19 Switch the back panel power button off and then on again and turn the front panel power button on The internal temperature has reache...

Страница 18: ...hen actively operating in current limit the safety circuits add noise to the output If I run my QCL at about 5 of maximum output current the transfer function becomes non linear and I see distortion i...

Страница 19: ...instrument cannot drive current through the load Make sure the QCL SMA or Pins 5 9 of the QCL D SUB are connected A short circuit was detected at the load terminals Please verify the load and load co...

Страница 20: ...ge input and the current is still not compliance voltage limited the instrument is operating at its lowest voltage and the voltage limit cannot be reduced further USE PASSIVE AND ACTIVE INTERLOCKS The...

Страница 21: ...found at www teamwavelength com support software downloads 3 Extract the file on the flash drive It should contain the following files INSTALL INI QCLxx ABL IMG QCLxx APP IMG QCLxx INSTALL INI NOTE Q...

Страница 22: ...22 MECHANICAL SPECIFICATIONS 0 72 3 89 0 66 16 8 3 92 99 6 6 10 154 9 8 49 215 6 Dimensions are in inches mm Tolerance is 5 8 860 225 0 3 47 88 14 8 860 225 0 16 35 415 16 35 415 17 72 450 3 47 88 14...

Страница 23: ...patibility tested to IEC 61000 3 2 and IEC 61000 3 3 IEC 61000 4 2 IEC 61000 4 3 IEC 61000 4 4 IEC 61000 4 5 IEC 61000 4 6 and IEC 61000 4 8 European Council Directive 2014 35 EC 26 February 2014 on L...

Страница 24: ...tion contained in this document is subject to change without notice Wavelength will not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishi...

Отзывы: