manualshive.com logo in svg
background image

9

Annual Sanitization

NOTICE

Do not change your post-carbon filter 

until the sanitization has been complet-

ed.  The pre-filters and membrane can 

be changed before the sanitization
Step A -

   Turn off the water supply to your 

RO system at the Adapt-A-Valve 

and open the RO faucet to drain 

the storage tank .  

NOTICE

If you have connected your RO system 

to a refrigerator/ice maker, make sure 

the connection has been turned off.  

Do not re-open the connection until 

the sanitization process is complete.
Step B -  

 Locate the tube that runs be-

tween your filter module and the 

storage tank and disconnect at 

both ends .

Step C -   

Drain any remaining water in the 

tube

Step D -  

 Hold both ends of the tube 

together with the ends pointed 

away from your face .  Using 

a dosing syringe (see figure) 

slowly insert 1 teaspoon (5 mL) 

of common household bleach 

into the tube .

WARNING

!

  

Do not use needle syringe
Step E -  

 While covering one end of the tube with your finger, insert 

the other into the tank .  Then insert the open end into the 

filter module .  

Step F - 

   Turn the incoming water back on and let the system fill for 

approximately 10 minutes

Step G -    

Turn off the incoming water and let the system sit for 1 

minute .

Step H -  

  Drain the system completely and then follow the startup 

procedure - filling then draining two full tanks of water .  

Step I -    

Replace the post-carbon filter once complete .

DANGER

!

IF BLEACH GETS IN EYES: Hold eye open 

and rinse slowly and gently with water for 15 - 

20 minutes. Remove contact lenses if present, 

after the first 5 minutes, then continue rinsing 

eye. Call a poison control center or doctor for 

treatment advice. 

Check Air Pressure in the Tank

NOTICE

Check air pressure only when tank is empty of water!

Check air pressure in the storage tank 

when you notice a decrease in available 

water from the RO system . Air can be 

added with a bicycle pump using the 

schrader valve that is located on the lower 

side of the tank behind the blue plastic 

cap .

Step A -   

Turn off the incoming water 

supply to the RO .

Step B -   

Open the RO Faucet and allow 

water to drain from the tank until 

it is completely empty .

 TIP:  

 When water from the RO faucet slows to a trickle, with 

the faucet still in the open position, you may add air to 

the tank to purge any left over water, this will ensure 

that the tank is completely empty. 

Step C 

-   Once all water in the tank is purged, check air pressure 

using an air pressure gauge, it should read between 5 - 7 

PSI . (Digital air pressure gauge is recommended)

Step D -   

Follow startup procedure on page 8 .

Flow Restrictor Maintenance

Your reverse osmosis system is equipped 

with a Spiral flow restrictor .  This flow 

restrictor is pre-installed inside of the drain 

connection elbow labeled “Drain” .  It is 

maintenance free and does not need to 

be replaced when the RO membrane is 

changed .

TO REMOVE

SCHRADER

VALVE

FLOW

RESTRICTOR

ELBOW

POINT HOSE  
ENDS AWAY  
FROM FACE

DOSING SYRINGE  
WITH NO NEEDLE

Содержание WQC4RO11-50

Страница 1: ...t Technical Warranty Information Performance Data Sheet 13 14 Arsenic Fact Sheet 14 Service Record 15 Limited Warranty 16 System tested and certified by WQA against NSF ANSI Standard 58 for the reduct...

Страница 2: ...s The second stage contains a five micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane Recommended change...

Страница 3: ...local regulations during installation Contents of Reverse Osmosis RO System 1 Tank 1 RO Module with Filters 1 Parts Bag 1 Faucet Box 1 Manual If any of the items are missing please contact prior to i...

Страница 4: ...01504 Automatic Shut Off Valve ASOV J FU AGLR C 3 68102443 Air Gap Long Reach Chrome Faucet Option K FNP3033CP US05 68102285 Non Air Gap Long Reach Chrome Faucet Option L F122051 68101496 50 GPD Flow...

Страница 5: ...g it for a sprayer or soap dispenser see Step A NOTICE Porcelain sinks are extremely hard and can crack or chip easily Use extreme caution when drilling Watts accepts no responsi bility for damage res...

Страница 6: ...l screwdriver to feed through the drain saddle into the drain pipe to aid with the alignment Using a Phillips screw driver tighten the drain saddle bolts evenly and securely on both sides NOTICE Do no...

Страница 7: ...cat ed at the bottom of the recess for the tank connection Step 2 B Thread the plastic valve onto the tank fitting NOTICE DO NOT use teflon tape on plastic tank DO NOT over tighten or the valve could...

Страница 8: ...you have an 11 inch or 13 inch product and replace in 12 mos Model Part Description WQCSC11 68108818 Sediment Filter 11 inch WQCSC13 68108819 Sediment Filter 13 inch WQCCC11 68108777 Pre Carbon Filter...

Страница 9: ...nce complete DANGER IF BLEACH GETS IN EYES Hold eye open and rinse slowly and gently with water for 15 20 minutes Remove contact lenses if present after the first 5 minutes then continue rinsing eye C...

Страница 10: ...frequently over the next 24 hours to ensure no leaks are present NOTICE If you have connected your RO system to a refrigerator ice maker make sure the ice maker is off do not allow water to flow to t...

Страница 11: ...ntinues check incoming water 3 System is constantly running Crimps in tubing Check tubing and straighten or replace as necessary Clogged pre filters Replace prefilters Fouled Membrane Replace Membrane...

Страница 12: ...taste from water Tank needs to be sanitized Sanitize your system Filters are Fouled Replace Filters Filters weren t removed prior to an ex tended period of non use Replace filters and Sanitize your s...

Страница 13: ...MENT PARTS AND CHANGE INTERVAL Note Depending on incoming feed water conditions replacement time frame may vary Determine if you have an 11 inch or 13 inch product Model Part Description Replacement I...

Страница 14: ...Sheet Performance Data Sheet cont This system has been tested according to NSF ANSI 58 for reduction of the substances listed below and to NSF ANSI 372 for lead free com pliance The concentration of...

Страница 15: ...__________ Model Number WQCRO4 Serial Number ______________ Date of Install _________________ Installed by __________________ Date Changed Sediment Pre Filter 6 Months Carbon Pre Filter 6 Months Membr...

Страница 16: ...d 100 pounds per square inch 6 Incoming water to the filter system cannot exceed 100 degrees F 38 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is...