Procedure for Extended Non-Use 

(More than 2 months)

Step A -   

Turn off the water supply to your RO system at the Adapt-

A-Valve and open the RO faucet to drain the storage tank .  

Once the storage tank is empty, remove all filter cartridges 

(order not important), place them into a sealed plastic bag 

and store in your refrigerator . 

NOTICE

DO NOT FREEZE

Restart Instructions

Step A -   

Reinstall all filters on to the RO unit . Filters are color coded 

to match the filter heads they snap in to .  Refer to page 7, 

Step 11 for cartridge installation procedure .

Step B -   

Turn on water supply to the system at the Adapt-a-Valve . 

Check frequently over the next 24 hours to ensure no 

leaks are present .

NOTICE

 If you have connected your RO system to a refrigerator / ice 

maker, make sure the ice maker is off (do not allow water to flow 

to the ice maker) until the tank has been allowed to completely 

fill.

Step C -   

Open the RO faucet and leave it open until water begins to 

trickle out (it will come out slowly) .

Step D -  

 Close the RO faucet allowing the storage tank to fill with 

water .  It may take 3 to 6 hours to fill the tank completely 

depending on the production capability of the membrane, 

local water temperature and water pressure . 

Step E -   

After the Tank has filled, open the RO Faucet to flush the 

tank completely . You will know that the tank is empty 

when the flow rate from the RO faucet is down to a trickle .  

The second tank can be used for drinking .

Содержание WQC4RO11-50

Страница 1: ...t Technical Warranty Information Performance Data Sheet 13 14 Arsenic Fact Sheet 14 Service Record 15 Limited Warranty 16 System tested and certified by WQA against NSF ANSI Standard 58 for the reduct...

Страница 2: ...s The second stage contains a five micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane Recommended change...

Страница 3: ...local regulations during installation Contents of Reverse Osmosis RO System 1 Tank 1 RO Module with Filters 1 Parts Bag 1 Faucet Box 1 Manual If any of the items are missing please contact prior to i...

Страница 4: ...01504 Automatic Shut Off Valve ASOV J FU AGLR C 3 68102443 Air Gap Long Reach Chrome Faucet Option K FNP3033CP US05 68102285 Non Air Gap Long Reach Chrome Faucet Option L F122051 68101496 50 GPD Flow...

Страница 5: ...g it for a sprayer or soap dispenser see Step A NOTICE Porcelain sinks are extremely hard and can crack or chip easily Use extreme caution when drilling Watts accepts no responsi bility for damage res...

Страница 6: ...l screwdriver to feed through the drain saddle into the drain pipe to aid with the alignment Using a Phillips screw driver tighten the drain saddle bolts evenly and securely on both sides NOTICE Do no...

Страница 7: ...cat ed at the bottom of the recess for the tank connection Step 2 B Thread the plastic valve onto the tank fitting NOTICE DO NOT use teflon tape on plastic tank DO NOT over tighten or the valve could...

Страница 8: ...you have an 11 inch or 13 inch product and replace in 12 mos Model Part Description WQCSC11 68108818 Sediment Filter 11 inch WQCSC13 68108819 Sediment Filter 13 inch WQCCC11 68108777 Pre Carbon Filter...

Страница 9: ...nce complete DANGER IF BLEACH GETS IN EYES Hold eye open and rinse slowly and gently with water for 15 20 minutes Remove contact lenses if present after the first 5 minutes then continue rinsing eye C...

Страница 10: ...frequently over the next 24 hours to ensure no leaks are present NOTICE If you have connected your RO system to a refrigerator ice maker make sure the ice maker is off do not allow water to flow to t...

Страница 11: ...ntinues check incoming water 3 System is constantly running Crimps in tubing Check tubing and straighten or replace as necessary Clogged pre filters Replace prefilters Fouled Membrane Replace Membrane...

Страница 12: ...taste from water Tank needs to be sanitized Sanitize your system Filters are Fouled Replace Filters Filters weren t removed prior to an ex tended period of non use Replace filters and Sanitize your s...

Страница 13: ...MENT PARTS AND CHANGE INTERVAL Note Depending on incoming feed water conditions replacement time frame may vary Determine if you have an 11 inch or 13 inch product Model Part Description Replacement I...

Страница 14: ...Sheet Performance Data Sheet cont This system has been tested according to NSF ANSI 58 for reduction of the substances listed below and to NSF ANSI 372 for lead free com pliance The concentration of...

Страница 15: ...__________ Model Number WQCRO4 Serial Number ______________ Date of Install _________________ Installed by __________________ Date Changed Sediment Pre Filter 6 Months Carbon Pre Filter 6 Months Membr...

Страница 16: ...d 100 pounds per square inch 6 Incoming water to the filter system cannot exceed 100 degrees F 38 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is...

Отзывы: