10
5. System configuration
5.1 System configuration without central unit
5.1.1 Standalone installation: only one controller or multiple controllers without interconnection.
BT-D03 RF
WFC-03 HC RF
BT-WR02 RF (Option)
WFC-03 HCM RF 230 (Option)
BT-A03 RF
Device 1
Device 2
Remarks
By pressing
for 5 seconds, the con-
troller goes in RF pairing menu.
By using
and
select zone 1 (LED
blinks red), press
to enter in Pairing
with thermostat mode. The green blink-
ing LED is a position indicator.
Move the green blinking LED with
and to select the zone(s) to be paired.
Select/deselect the zone with .
Selected zone is fix red but keeps blink-
ing green (position indicator).
Already paired zone is fix green.
Thermostats :
Put product in RF pairung mode
(refer to corresponding instruction
manual).
If RF pairing is done, the LEDs of the
zones selected on the WFC-03 HC RF
must turn off and the thermostats must
exit the pairing mode.
To pair another thermostat, you need to
enter/start the mode again.
Exit of the controller pairing menu: Long
press on
.
By pressing
for 5 seconds, the
controller goes in RF pairing menu.
By using
and
select zone 3
(Red led), press
to enter in Pairing
with a slave device mode.
All LEDs are blinking green.
Put the device in RF pairing mode
(Press 10s on the button).
When link is done, WFC-03 HC RF
returns to the RF pairing menu and
WFC-03 HCM RF 230 returns to
normal mode.
Exit of the controller pairing menu: Long
press on
.
REMARK:
only one WFC-03 HCM RF 230 per
installation.