background image

UK 

ENGLISH 

DSBA3003 • Rév. 07/07/2020  

13 

DESCRIPTION 

These electric actuators have been designed to perform the control of a valve with 90° rotation. Please consult us for any 
different application. We cannot be held responsible if the mentioned actuators are used for any other purpose. 
 

TRANSPORT AND STORAGE 



The forwarding agents being held as responsible for damages and delays of the delivered goods, the consignees are 
obliged to express if applicable their reserves, prior to accept the goods. The goods delivered directly ex works are sub-
ject to the same conditions. 



The transport to the place of destination is carried out by using rigid packing material. 



The products must be stored in clean, dry, and ventilated places, preferably on appropriate palettes or shelves. Actua-
tors should not be stored upside down. 

 

MAINTENANCE 



Maintenance is ensured by our factory. If the supplied product does not work, please check the wiring according to the 
electric diagram as well as the power supply of the electric actuator in question. 



For any question, please contact our after-sales service. 



To clean the outside of the actuator, use a lint and soapy water. DO NOT USE ANY CLEANING PRODUCT WITH SOL-
VENT OR ALCOHOL.  



Before any intervention on the actuator or around the actuator, to avoid any electrostatic discharge, the apparatus 
shall be cleaned with a damp cloth  

 

WARRANTY 



Valpes products are thoroughly tested and set in factory. 



These products are 3-year warranty from the manufacturing site delivery  date or 50,000 actuations against all types of 
manufacturing and material faults (operating time and model class according to standard CEI34). 



The said guarantee covers solely replacement or – at the full sole discretion of Valpes - repair, free of charge, of those 
components of the goods supplied which in the sole view of Valpes present proven manufacturing defects. 



This warranty excludes any damage due to normal product usage or friction and does not include any modified or unau-
thorized repair for which Valpes will not accept any request for damage (either direct or indirect) compensation (for full 
details see our website).  



The guarantee does not cover the consequences of breakdown and excludes any payments for indemnities. The acces-
sories, consumables (batteries…)  and adaptations are excluded from the guarantee. In the case where a customer has 
not proceeded to payments within the agreed period, our guarantee will be suspended until the delayed payments have 
been received and with the consequence that this suspension will not prolong the guarantee period in any case. 



All sales subject to the Valpes terms to be found on www.valpes.com.  

 

RETURN OF GOODS 



When the actuator receives his actuator, he must check its conformity according to its definition. 



The acceptance of the goods by the purchaser disclaims the supplier of all responsibility if the purchaser discovers any 
non-conformity after the date of acceptance. In such case, the repair cost will be borne by the purchaser who will also 
exclusively bear all financial consequences of any resulting damages. Returned goods will only be accepted if our prior 
agreement has been given to this procedure : the goods must be sent free of all cost and being shipped solely and in 
their original packing. The returned goods will be credited to the purchaser with a reduction of

 

40% on the unit’s price 

charged in accordance with the original invoice of the returned goods. 

 

SAFETY INSTRUCTIONS

 

 

 

    (To be read prior to the installation of the product

)

 



The electric power supply must be switched-off before any intervention on the electric actuator (i.e. prior de-
mounting its cover or manipulating the manual override knob). The operator must also be sure that no explosive 
atmosphere is present around the actuator before any maintenance operation. 



Heat flow from the valve and pipes: it is the responsibility of the user to consider the influence of radiated heat on 
the final installation because the electrical actuator is certified for a specific ambient temperature range.  



Any intervention must only be carried out by a qualified electrician or other person instructed in accordance with the reg-
ulations of electric engineering, safety, and all other applicable directives. 



Strictly observe the wiring and set-up instructions as described in the manual: otherwise, the proper working of the actu-
ator can not be guaranteed anymore. Verify that the indications given on the identification label of the actuator fully corre-
spond to the  characteristics of the electric supply. 

 

MOUNTING INSTRUCTIONS

 

 

    (To be read prior to the installation of the product

)

 



Do not mount the actuator less than 30 cm from an electromagnetic disturbance source. 



Do not mount the actuator « upside down ». 



Do not position the equipment so that it is difficult to operate the disconnecting device. 



Respect all safety rules during fitting, dismantling and porting of this apparatus.   



WARNING – DO NOT OPEN WHEN ENERGIZED  



WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT 



WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD – SEE INSTRUCTIONS  

Содержание Valpes VTX Series

Страница 1: ...re protection 600Nm Facteur de marche 50 Duty cycle Anticondensation intégrée Anticondensation heater VTX Actionneur électrique Manuel d Installation et d Utilisation p 2 Installation and Operation Manual p 12 Installations und Bedienungsanleitung p 22 Manual de instalación y funcionamiento p 32 FR UK DE ES Valpes com ...

Страница 2: ...on 14 Dimensions 15 Emergency manual override 15 Electric wiring 16 Warnings Wiring Instructions Electric diagrams Technical data 20 Français 2 English 12 Deutsch 22 Español 32 This product meets the European Directive 2012 19 UE about electrical and electronic equipment DEEE It mustn t be mixed with common waste Please recycle or dispose of them according to your country laws ...

Страница 3: ...spended until the delayed payments have been received and with the consequence that this suspension will not prolong the guarantee period in any case All sales subject to the Valpes terms to be found on www valpes com RETURN OF GOODS When the actuator receives his actuator he must check its conformity according to its definition The acceptance of the goods by the purchaser disclaims the supplier of...

Страница 4: ...1 Position indicator 7 M20x1 5 treated holes 1 2 NPT en option 2 Cover 8 Earth screw 3 Detection switches Motor feedback 9 Mechanical stops 4 Cams 10 Wheel 5 Motor 11 F10 F12 cast iron plate 6 O ring A CHC M8 x 30 A2 70 B CHC M8 x 20 A2 70 C CHC M6 x 16 A2 70 D CHC M6 x 30 Class 12 9 Actuators description ...

Страница 5: ... to be turned appendix p 14 mark 10 Anticlockwise to open The mechanical stops mustn t be removed Mounting dismantling of the cover and position indicator For the wiring and setting of the actuator it is necessary to remove the cover Mounting of the cover appendix p 14 mark 2 make sure that the seal ring appendix p 14 mark 6 is correctly placed in its posi tion grease of the flame path Molydal 3790...

Страница 6: ...ot exceed 1mA The actuator can tolerate temporary overvoltage of the electrical grid up to 10 of its nominal system operat ing voltage The selection of the cables and cable glands the maximal operating temperature of the cables and cable glands must be at least 110 C It is necessary to connect all actuators to an electrical cabinet The power supply cables must have the RATED diameter for the maxim...

Страница 7: ... DSBL0493 400V inside the cover As per factory setting the white cam is used to detect the open position FC1 and the black cam is used to detect the closed position FC2 The auxiliary limit switches must be connect with rigid wires If the applied voltage is higher than 42V the user must foresee a fuse in the power supply line Unscrew the right cable gland and insert the cable Remove 25mm of the cab...

Страница 8: ...imit switch FCF Close limit switch FC1 Auxiliary limit switch 1 FC2 Auxiliary limit switch 2 C Capacitor F Motor thermoswitch Rep Designation TLO Torque switch opening TLF Torque switch closing H Anti condensation heater M Motor VL Purple MR Brown RG Red NR Black BU Blue OG Orange BC White D1 D2 Failure report terminal 230V AC max 5 A 230V electric diagram The terminal temperature can reach 90 C T...

Страница 9: ...Close limit switch TLO Torque switch opening FC1 Auxiliary limit switch 1 FC2 Auxiliary limit switch 2 TLF Torque switch closing BC White F Motor thermoswitch H Anti condensation heater M Motor VL Purple MR Brown RG Red NR Black BU Blue OG Orange D1 D2 Failure report terminal 230V AC max 5 A The motor power supply is wired on bistable three phase relay not delivered If working inverted invert 2 ph...

Страница 10: ... to 31 C decreasing linearly to 50 rela tive humidity at 40 C Pollution degree Applicable POLLUTION DEGREE of the intended environment is 2 in most cases Weight 25kg Mechanical data Nominal torque 450Nm 600Nm Maximum torque 600Nm 1000Nm Operating time 90 42s 65s Angular range 90 180 270 on request Duty cycle 50 Drive ISO5211 Star 36 depth 41mm F10 F12 depth F10 25mm F12 30mm Manual control Secured...