background image

DSBA3100 • Rév. 03/05/2019 

ENGLISH 

UK 

Po

w

e

su

p

p

ly

 a

n

d C

o

n

tr

o

bo

a

rds

 

fo

r E

R

 20 

*  Fuses for multivolt boards  
 

- SNAA670100 board: 1A / T (Schurter 0034.6615 ) 

 

- SNAA670000 board: 500mA / T (Schurter 0034.6612 ) 

 

- SNAA680100 board: 3.15A / T (Schurter 0034.6620 ) 

 

- SNAA680000 board: 1A / T (Schurter 0034.6615 ) 

 
**  Possible defects : limitation of current, thermic limitation or program error 
 

=> check that the valve torque is not superior to the maximum torque stand by the actuator 

 

=> check that the actuator do not exceed the duty cycle indicated (possible overheat) 

 

To re-start the actuator, reverse the sense of rotation or switch the power off and on. 

Electronic boards

 

REP 

DESIGNATION 

REP 

DESIGNATION 

Earth screw 

  D** 

LED 2 : detected failure 

Power supply and control terminal 

LED 1 : power supply presence 

*

C* Protection 

fuses 

 

 

Po

w

e

su

p

p

ly

 a

n

d C

o

n

tr

o

bo

a

rds

 

fo

r E

R

 35-

6

0

-1

00 

SNAA670100 

24V 50/60Hz (24V DC) 

SNAA670000 

100V-240V 50/60Hz (100V-350V DC) 

SNAA680100 

24V 50/60Hz (24V DC) 

SNAA680000 

100V-240V 50/60Hz (100V-350V DC) 

Содержание VALPES ER PREMIER

Страница 1: ...ER PREMIER Installation and Operation Manual UK 20Nm Facteur de marche 30 Duty cycle Indice de protection IP65 Enclosure protection Electric actuator...

Страница 2: ...ion indicator 4 Emergency manual override 4 Dimensions 5 Electric wiring 6 Warnings Wiring Instructions Electric diagram Electronic boards Technical data 9 This product meets the European Directive 20...

Страница 3: ...bles batteries and adaptations are excluded from the guarantee In the case where a customer has not proceeded to pay ments within the agreed period our guarantee will be suspended until the delayed pa...

Страница 4: ...ated Valve 0 180 2 way 0 close 90 open 3 way L 3 way T Ex T1 90 Emergency manual override The priority functioning mode of this actuator is electric Be sure than the power supply is switched off befor...

Страница 5: ...4 plate Ou Or Sleeve 9 Nylon GF PA6 Housing Clutch knob 11 Square Star mm Depth mm 14 16 17 19 22 24 ISO F ange Diameter mm F03 36 F04 42 F07 70 M threaded Depth mm M5 14 2 M5 14 2 M8 16 4 Screws quan...

Страница 6: ...cated on the actuator ID label corresponds to the voltage supply Connect the wires to the connector in accordance with the required control mode see diagram p 15 To ensure the correct functioning of t...

Страница 7: ...id feedback voltages 4 to 250V AC DC FEEDBACK COMMON FC1 FC2 FEEDBACK FC1 FEEDBACK FC2 1 2 3 ECD 1A Grey connector 9 8 7 6 5 4 1 2 3 SUGGESTED CUSTOMER WIRING N Open Close Ph N Open Ph Modulating 3 po...

Страница 8: ...torque stand by the actuator check that the actuator do not exceed the duty cycle indicated possible overheat To re start the actuator reverse the sense of rotation or switch the power off and on Ele...

Страница 9: ...00Nm 1 4 turn travel time 13s 8s 15s 25s Mounting actuator base ISO 5211 Star 14 F03 F04 F05 Star 22 F05 F07 Swing angle 90 others on request Mechanical end stops 90 5 Manual override Out axle Directi...

Отзывы: