DSBA3100 • Rév. 03/05/2019
ENGLISH
UK
TECHNICAL DATA
Type (1/4 turn electric actuator)
ER20
ER35
ER60
ER100
Housing type
Small housing (see p.13)
large housing (see p.13)
IP protection (EN60529)
IP65
Corrosion resistance (outdoor and
indoor use)
Housing: PA6 25% GF and cover: PA6 UL94V0
Raw material : 304L Stainless Steel or Steel + Zn treatment
Temperature -10°C
to
+55°C
Hygrometry
maximum relative humidity 80 % for temperatures up to 31 °C decreasing linearly
to 50 % relative humidity at 40 °C
Pollution degree
Applicable POLLUTION DEGREE of the intended environment is 2 (in most cases).
Altitude
altitude up to 2 000 m
Extended environmental conditions
Outdoor use and in WET LOCATION
Sound level
61 dB
Weight 1
Kg 2.1
Kg
MECHANICAL DATA
Nominal torque
20Nm
35Nm
60Nm
100Nm
1/4 turn travel time
13s
8s
15s
25s
Mounting actuator base (ISO 5211)
Star 14
F03-F04-F05
Star 22
F05-F07
Swing angle
90° (others on request)
Mechanical end stops
90° +/- 5°
Manual override
Out axle
Direction of rotation
Anticlockwise to open
Voltage ±10%
24V AC 50/60Hz or 100V to 240V AC 50/60Hz
24V DC or 100V to 350V DC
Frequency 50/60Hz
Power consumption
15W (0.08A) cos j = 0.75
45W (0.15A) cos j = 0.75
Overvoltage category
TRANSIENT OVERVOLTAGES up to the levels of OVERVOLTAGE CATEGORY ll
TEMPORARY OVERVOLTAGES occurring on the MAINS supply
Torque limiter
Electric
Duty cycle (CEI34)
30%
Limit switches maximal voltage
4 to 250V AC/DC
(Overvoltage category II)
Limit switches maximal current
1mA to 5A max
Electrical wiring
1 ISO M20 cable gland and 1 DIN43650 3P+T connector
Inrush current
Circuit breaker type D, nominal current according the number of actuators (max. 4 actuators) or
use a inrush current limiter at the output of the circuit breaker.
ELECTRICAL DATA