manualshive.com logo in svg
background image

5

Feed Water Requirements

Please review operating pressures, temperatures and water 

chemistry limitations to ensure compatibility.

Installation 

  1.    Remove all system components from packaging and 

inspect for any damage. Confirm that the system being 

installed matches the flow rate for the application.   

  2.   Turn off water heater(s).  
  3.    Turn off the main water supply valve to the pipe the system 

will be installed in.

  4.    Relieve pressure within plumbing system by opening then 

closing both the hot and cold sides of a faucet until water 

ceases to dispense from faucet.

  5.    If equipped with isolation valves, isolate the water heater(s) 

by closing its inlet and outlet valves.  

  6.    Mount the UV system mounting clips on the installation sur-

face using appropriate hardware for your mounting surface 

type. Mounting screws have been provided for mounting 

the system to wood. The mounting surface and hardware 

must be sturdy enough to support the weight of the wetted 

system.

  7.    Insert UV chamber through the mounting clips.
  8.    Connect the water supply pipe to the inlet of the UV sys-

tem.

  9.    Install a supply valve in this supply line. 
10.    Install an adequately sized 5 micron cartridge filter in this 

supply line after the supply valve. The cartridge filter must 

have a higher flow rate rating than the UV system. 

11.    Connect the outlet of the system to the outlet plumbing.
12.    Install a flow controller in this outlet plumbing (optional).
13.    Install an outlet valve in this outlet plumbing line.
14*.   Install the quartz sleeve into the UV chamber closed end first. 

DO NOT

 touch the quartz sleeve with your fingers. Hold it with 

a paper towel. 

15*.   Loosen the Phillips set screw on the side of the quartz 

sleeve nut and separate the nut from the power cord. 

16*.   Install the quartz sleeve nut o-ring onto the visible end of 

the quartz sleeve. Screw the quartz sleeve nut onto the 

quartz sleeve port thread and tighten hand tight.

17*.   Install the ultraviolet lamp into the quartz sleeve. 

DO NOT

 

touch the lamp with your fingers. Hold it with a paper towel. 

Note: 

Only the 120 volt system uses the strainrelief and ground-

ing set screw. The 230 volt systems has only the 4 pin plug and 

rubber cap. See page 8.
18*.   Insert the lamp power lead wire into the receptacle on the 

lamp and rejoin the two halves of the quartz sleeve nut. 

Tighten the Phillips set screw on the side of the quartz 

sleeve nut. 

19.   Open water supply valve.
20.   Check for leaks and repair as needed.
21.    Plug power cord into an outlet that is protected by a ground 

fault interrupt.

22.   Open outlet valve.
23.    Purge air from plumbing system out of the nearest cold 

water faucet to the UV system.

24.    Open inlet and outlet isolation valves on water heaters(s) 

and turn water heaters back on.

25.   Perform the sterilization procedure within this manual.
       * For assistance with installation steps 14-18 see replace-

ment procedures for lamp and quartz sleeve within this 

manual.

Max Water Pressure

100 psi (6.9 bar)

pH

6.5-8.5

Water Temperature

36°F to 104°F (2°C to 40°C)

Turbidity

<5 Nephelometric Turbidity Units (NTU)

Iron (maximum)

0.3 mg/l

Manganese (maximum) 0.05 mg/l

Maximum Ambient 

Atmospheric 

Conditions

Temperature 122°F / 50°C 

90% Relative Humidity 

Oil & H2S

None allowed

Support the Piping

The full weight of the piping and valves must be 

supported by uni-strut, pipe hangers or other 

means.

 

WARNING

!

Inspect wall for hidden wiring before drilling any holes or 

installing screws.

 

WARNING

!

Содержание SmartStream UV WA002

Страница 1: ...ty damage or damage to the equipment Keep this Manual for future reference WARNING Installation Precautions 2 System Specifications 3 Product Specification Tables 4 Dimensions 4 Feed Water Requirements 5 Installation Procedure 5 Installation Diagram 6 Maintenance 7 Parts List 7 Lamp and Quartz Sleeve Replacement 8 Disinfection Procedure 9 Troubleshooting 9 Warranty and Conditions 10 Table of Conte...

Страница 2: ...ream system Be certain that the feed water meets all criteria within the Feed Water Specifications section of this manual WARNING Installation Guidelines DO NOT allow this system to remain ON with out water in it for extended periods of time DO NOT install the system near any source of heat Also DO NOT install the system near any device or break out area that would be adversely effected by water D...

Страница 3: ...he system requires servicing SmartStream UV System Part Number Identification Key Prefix W Controller Series GPM Connection Type Pipe Size Plug Accessories Watts Controller Type A Controller A GPM of System 3 Digits Connection Port Types A NPT B BSP Tapered Pipe Size B 3 8 C 1 2 D 3 4 E 1 A North American 120V B European 220V Accessories X No Accessories Green Red LED Indicator System Features A S...

Страница 4: ...Red LED AUDIBLE ALARM Yes AUDIBLE ALARM MUTE No MIN MAX AMBIENT AIR TEMPERATURE MAX HUMIDITY 32 F 0 C to 122 F 50 C 90 RH non condensing INLET WATER TEMPERATURE RANGE 36 F 2 C to 104 F 40 C MAX WATER PRESSURE 100 psi 689 kPa SHIPPING WEIGHT 4 6 lbs 2 1 Kg 6 4 lbs 2 9 Kg 8 lbs 3 7 Kg 11 lbs 5 Kg Dimensions A Series UV Systems Model GPM A B C D E F WA002 2 1 1 14 17 17 65 3 83 3 09 14 WA006 6 1 2 22...

Страница 5: ...ith a paper towel 15 Loosen the Phillips set screw on the side of the quartz sleeve nut and separate the nut from the power cord 16 Install the quartz sleeve nut o ring onto the visible end of the quartz sleeve Screw the quartz sleeve nut onto the quartz sleeve port thread and tighten hand tight 17 Install the ultraviolet lamp into the quartz sleeve DO NOT touch the lamp with your fingers Hold it ...

Страница 6: ...6 Typical Installation Diagram ...

Страница 7: ...VQS6 UV QUARTZ SLEEVE FOR 6 GPM 530MM X 24 5MM A SERIES 2c 1 WUVQS8 UV QUARTZ SLEEVE FOR 8 GPM 680MM X 24 5MM A SERIES 2d 1 WUVQS12 UV QUARTZ SLEEVE FOR 12 GPM 910MM X 24 5MM A SERIES 3 1 HSFSUVOR UV QUARTZ SLEEVE O RING FOR A SERIES 4a 1 WUVLAMP2 UV LAMP FOR 2 GPM A SERIES 4b 1 WUVLAMP6 UV LAMP FOR 6 GPM A SERIES 4c 1 WUVLAMP8 UV LAMP FOR 8 GPM A SERIES 4d 1 WUVLAMP12 UV LAMP FOR 12 GPM A SERIES ...

Страница 8: ...artz sleeve into the reactor chamber Be careful not to force the quartz sleeve breakage may occur Then install the o ring over the quartz sleeve 9 Install the quartz sleeve nut onto the threaded port of the reactor chamber Screw the quartz sleeve nut on clockwise and tighten hand tight 10 Turn on the inlet valve and check for leaks Repair leaks as needed 11 Insert a new lamp into the quartz sleeve...

Страница 9: ... connection Low pressure after system Clogged prefilter Replace prefilter Quartz sleeve nut leaks Quartz sleeve nut loose Tighten quartz sleeve nut O ring is defective Replace o ring All problem conditions called out within this troubleshooting chart require the disinfection procedure to be conducted after the corrective action has been completed NOTICE 1 Shut off the isolation valves on the cartr...

Страница 10: ...hed installation and operation manual product specifi cation sheet and local plumbing codes This product must be installed in connection with an approved water supply This product must be operated at water pressures and temperatures that do not exceed the Company s published specifications This product is limited to use within atmospheric environments indoors that are within ambient temperature li...

Отзывы: