3
System Specifications
Controller Features
Series A Controller
SmartStream
™
A series UV Controllers are designed with simplicity
in mind. Input power is converted to the correct voltage required by
the lamp for the production of UV light. During normal operation, the
LED indicator will be illuminated green. If the lamp burns out then
an audible alarm will sound and the Green/Red LED Indicator will
change from Green to Red. This informs the user that the system
requires servicing.
SmartStream
™
UV System Part Number Identification Key
Prefix "W"
"Controller Series"
"GPM"
"Connection Type"
"Pipe Size"
"Plug"
"Accessories"
Watts
Controller Type
A: Controller A
GPM of System
(3-Digits)
Connection Port
Types:
A: NPT
B: BSP-Tapered
Pipe Size
B: 3/8"
C: 1/2"
D: 3/4"
E: 1"
A: North American
120V
B: European 220V
Accessories
X: No Accessories
Green/Red LED Indicator
System Features
A Series Controller With Lamp Out Alarm
GPM Rating
2
6
8
12
Model #
WA002
WA006
WA008
WA012
304 SS Chamber
4
4
4
4
Lamp Out Audible Alarm
4
4
4
4
Lamp On Indicator (Green LED)
4
4
4
4
Lamp Out Indicator (Red LED)
4
4
4
4
Wall Mounting Clips for Chamber
4
4
4
4
Содержание SmartStream UV WA002
Страница 6: ...6 Typical Installation Diagram ...