Setup

Unpack and check the system components for damage or missing 

parts.
Make sure that the bypass valve and plumbing yoke are properly 

connected to each other and to the control valve with the mounting 

clips. Make certain that the drain line flow control fitting is installed 

properly on the drain port of the control valve. Systems that are 13” 

in diameter and larger are not loaded with media. These systems 

must be loaded with media before placing into service. To load a 

system follow the below steps. 
  1.   Cap the top open end of the distributor tube with tape and plas-

tic sheeting to keep foreign debris from entering the distributor 

tube. This cap must be secure and not come off during media 

loading. 

  2.   Place the distributor tube, screen end down, into the mineral 

tank and center it in the bottom. The top of the distributor tube 

should be flush with the top of the tank. 

  3.   Make sure the plastic and tape cap is secure to the top of the 

distributor tube, place a funnel on the top of the tank and load 

first the gravel then the filter media into the tank. The cap must 

not come off of the distributor tube during the loading of the 

media. 

  4.   Remove the plastic cap from the distributor tube. DO NOT PULL 

UP ON THE DISTRIBUTOR TUBE when removing the cap. The 

distributor tube top must remain flush with the top of the tank. 

  5.   Clean any media from the threads and top of the mineral tank.
  6.   Lubricate the O-rings on the bottom of the control valve (dis-

tributor pilot O-ring and top of tank O-ring). Use non-petroleum 

based silicone lubricant only.

  7.   Place the control valve on top of the tank. When doing this step, 

seat the top of the distributor tube inside the centered O-ring 

sealed port on the bottom of the valve first then press the valve 

down until the tank threads come in contact with the valve 

threads. This ensures that the distributor tube is properly seated 

into the bottom of the control valve. Thread the valve on to the 

tank clockwise. Be careful not to cross thread the valve or over 

tighten it. A hand tight snug fit is appropriate for the control valve 

torque. A wrench is not necessary. Do not use thread sealant or 

PTFE tape on the valve base threads.

  8.   The system is now ready for installation.

Installation Considerations

Consider the following points when determining where to install  

the filter:
•   Place the system as close as possible to a sewer drain.
•   Do not install the filter where it would block access to the water 

heater, or access to the main water shutoff, water meter, or electri-

cal panels. 

•  Install the filter in a place where water damage is least likely to oc-

cur if a leak develops.

•  A 120VAC electrical outlet is needed to plug in the transformer. 
•  Always connect the system to the main water supply pipe before 

the water heater.

•   Install the system where it will not be subject to temperatures 

outside of the limits stated in the Specification section or to direct 

sunlight.

•   Make sure the installation surface is smooth, level, and sturdy 

enough to support the weight of the wetted system.

Содержание PWSYS-WH-MICROZ

Страница 1: ...ection before or after the system Local building or plumbing codes may require modifications to the information provided You are required to consult the local building and plumbing codes prior to inst...

Страница 2: ...e filter see the Installation Considerations section of this manual Do not attempt to treat water over 110 F 43 C with the system Always connect the system to the main water sup ply pipe before the wa...

Страница 3: ...3 Filter Anatomy 1 2 3 4 5 6 7 Item Description 1 Valve 2 Bypass 3 Tank 4 Distributor 5 Filter Media Calcite Carbon or Micro Z 6 Faceplate Controls 7 Gravel Underbed...

Страница 4: ...tact your Watts representative MODEL NO Valve Mineral Tank Size Media Cubic Foot Gravel Lbs Service Flow GPM Pressure Drop PSI Back Wash GPM Floor Space LXWXH PWSYS WH MICROZ 1CUFT Time Clock 9 X 48 1...

Страница 5: ...rings on the bottom of the control valve dis tributor pilot O ring and top of tank O ring Use non petroleum based silicone lubricant only 7 Place the control valve on top of the tank When doing this...

Страница 6: ...ape on all external pipe threads Do not use pipe joint compound CAUTION Support inlet and outlet plumbing in some manner use pipe hangers to keep the weight off of the valve fittings 7 Place bypass va...

Страница 7: ...flowing through the system and sediment is being removed from your water if it s a Micro Z filter If it s a carbon filter it removes chlorine tastes odors and organics from your water If your system c...

Страница 8: ...remedies stated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED...

Отзывы: