manualshive.com logo in svg
background image

2

OneFlow

®

+ System Benefits

•  Reduces sediment, chlorine taste and odor
•  Chemical-free scale prevention and protection – converts 

hardness minerals to harmless, inactive microscopic crystals 

making OneFlow

®

+ systems an effective salt-free alternative 

to ion exchange water softeners

•  Virtually maintenance free – No salt bags or other chemicals 

to constantly add or maintain

•  No control valve, no electricity and no wastewater
•  Environmentally friendly technology adds no salt or chemicals 

to the water system

•  Improves efficiency of all water heating devices and 

downstream plumbing components

•  Simple installation – standard 1" connections 
•  Excellent system for homes where equipment protection 

is desired for longer equipment life and reduced energy 

consumption

•   OneFlow

®

+ cartridge-based systems are easily maintained

•  Easily installed mounting bracket and multi-function tool 

included to allow cartridge change-outs when necessary

Equipment Specifications

Watts OneFlow

®

+ systems are complete, self-contained, loaded 

with media and ready to use. A simple inlet and outlet connection 

is all that is required for installation. Please review operating 

pressures, temperatures and water chemistry limitations to 

ensure compatibility and performance.

Setup

Unpack and check the system components for damage or  

missing parts.

Installation Considerations

Consider the following points when determining where to install 

the system:
•  Do not install the system where it would block access to the 

water heater, main water shutoff, water meter, or electrical panels.

•  Install the system in a place where water damage is least likely 

to occur if a leak develops.

14

1

2

"

4

5

16

"

1

1

8

"

32" Min to 60" A.F.F.

Installation Height

Side View

Using OneFlow

®

+ System with Other Water 

Treatment Equipment

Due to the unique properties of OneFlow

®

+, there are some 

unique requirements for using OneFlow

®

+ in conjunction with 

filtration or other forms of water treatment.
1.   OneFlow

®

+ must be the last stage in the treatment chain. Do 

not install any filters after OneFlow

®

+ or before any devices for 

which scale prevention is required. POU filters, e.g. carbon, 

RO or Ultraviolet (UV) are exempt from this requirement.

2.   Do not apply any other antiscalants before or after 

OneFlow

®

+.

3.   The addition of soaps, chemicals, or cleaners, before or after 

OneFlow

®

+ treatment, may reverse its anti-scale treatment 

effects and/or create water with a heavy residue or spotting 

potential. Any adverse conditions caused by the addition of soaps, 

chemicals, or cleaners are the sole responsibility of the end user.

4.   OneFlow

®

+ is not a water softener and does not soften the 

water - Water treatment chemistry (e.g. antiscalants, sequestrants, 

soaps, chemicals or cleaners etc...) will most likely have to be 

changed to be compatible with OneFlow

®

+ treated water. Laundry 

and ware-washing chemistry will likewise require adjustments.

1" MNPT Inlet 

Connection 

from water 

supply

D

B

E

A

2

9

16

"

3

11

16

"

5

16

"

Back View

Dimensions — Weights

Model

Dimensions

Weight

A

B

C

D

E

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

lbs.

kgs

OFPSYS

18

3

4

476

5

11

16

144

8

1

16

205

11

3

8

289

5

1

2

140

16.6

7.5

The overall height and the height of the inlet fitting varies due to material variations and assembly tolerances. 
Please allow additional clearance above the system for making connections and replacing cartridge filters.

Содержание OneFlow OFPSYS

Страница 1: ...eater Do not expose the system to freezing temperatures Water freezing in the system causes equipment damage Do not install in direct sunlight Ultraviolet rays from the sun may cause damage Do not use...

Страница 2: ...he system in a place where water damage is least likely to occur if a leak develops 141 2 45 16 11 8 32 Min to 60 A F F Installation Height Side View Using OneFlow System with Other Water Treatment Eq...

Страница 3: ...bar to 6 2 bar Temperature 40 F to 100 F 5 C to 38 C Free Chlorine 2 ppm Iron maximum 0 3 ppm Manganese maximum 0 05 ppm Copper maximum 1 3 ppm Oil H2S Must be Removed Prior to OneFlow Total Phosphate...

Страница 4: ...ter Close the supply valve when a steady stream of water comes out of the outlet port If the outlet is flowing into a bucket water could splash on nearby objects If this threatens the safety value str...

Страница 5: ...that it is sealed correctly as shown in Diagram C 9 Insert Outlet Connector Item 8 into outlet port and secure back on top of the OneFlow Scale Reduction cartridge as shown in Diagram D 10 Place Head...

Страница 6: ...cloth or sponge In the bath Soaps and shampoos will rinse off much easier and faster than they would with traditional soft water We recommend the use of modern soaps for the best results Things to wat...

Страница 7: ...low Carbon Block Cartridge 7100640 OFPSP Scale Prevention Cartridge 7100641 OFPCOM Scale Prevention and Carbon Block Combo Pack ONEFLOW SYSTEM REPLACEMENT PARTS 7300759 OFPHSG Housing and Head Assembl...

Страница 8: ...freight and local labor charges if any Damage to the media due to chlorine other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under Specific...

Страница 9: ...ga el sistema a temperaturas bajo cero La congelaci n del agua en el sistema causa da os en el equipo No lo instale bajo la luz solar directa Los rayos ultravioletas del sol pueden causar da os No uti...

Страница 10: ...al medidor de agua o a los paneles el ctricos Instale el sistema en un lugar donde sea menos probable que se produzcan da os por agua si se produce una fuga 141 2 36 83 cm 45 16 10 95 cm 11 8 2 86 cm...

Страница 11: ...nganeso m ximo 0 05 ppm Cobre m ximo 1 3 ppm Aceite y H2S Deber n eliminarse antes de OneFlow Fosfatos totales 3 0 ppm S lice m ximo 20 ppm TDS 1500 mg L AVISO Los sistemas que utilizan la tecnolog a...

Страница 12: ...carcasa se llene de agua Cierre la v lvula de suministro cuando salga un flujo constante de agua por el puerto de salida Si la salida fluye hacia una cubeta el agua podr a salpi car los objetos cercan...

Страница 13: ...asegur ndose de que est sellado correctamente como se muestra en el diagrama C 9 Inserte el conector de salida elemento 8 en el puerto de salida y aseg relo nuevamente en la parte superior del cartuc...

Страница 14: ...bones y champ s se enjuagar n mucho m s f cil y r pido de lo que lo har an con el agua blanda tradicional Recomendamos el uso de jabones modernos para obtener los mejores resultados Detalles para tene...

Страница 15: ...al 7100640 OFPSP Cartucho de prevenci n de sarro 7100641 OFPCOM Paquete combinado de prevenci n de sarro y bloques de carbono PIEZAS DE REPUESTO DEL SISTEMA ONEFLOW 7300759 OFPHSG Conjunto de carcasa...

Страница 16: ...guno excluyendo el flete y los cargos de mano de obra local si corresponde Los da os a los medios debidos al cloro otros oxidantes o incrustaciones causadas por las condiciones locales del agua o cual...

Страница 17: ...mp ratures glaciales De l eau qui g le dans le syst me peut endommager l quipement N installez pas le syst me en plein soleil Les rayons ultraviolets du soleil peuvent causer des dommages N utilisez p...

Страница 18: ...g ts d eau sont les moins susceptibles de se produire en cas de fuite 141 2 po 368 3 cm 45 16 po 10 9 cm 11 8 po 2 9 cm 32 po min 60 po A F F 81 3 cm 152 4 cm Hauteur d installation Vue de c t Utilisa...

Страница 19: ...si 0 69 bar 6 2 bars Temp rature 40 F 100 F 5 C 38 C Sans chlore 2 ppm Fer maximum 0 3 ppm Mangan se maximum 0 05 ppm Cuivre maximum 1 3 ppm Huile et H2S Doivent tre retir s avant OneFlow Phosphates t...

Страница 20: ...eau Fermez le robinet d alimentation lorsqu un flux d eau r gulier s coule de l orifice de sortie Si la sortie coule dans un seau l eau peut cla bousser les objets proximit Si cela menace la s curit l...

Страница 21: ...assurant que celle ci est verrouill e correctement comme indiqu dans le sch ma C 9 Ins rez le raccord de sortie article 8 dans l orifice de sortie et fixez le sur le dessus de la cartouche antitartre...

Страница 22: ...et le shampoing se rincent galement bien plus facilement et plus rapidement qu avec de l eau douce conventionnelle Nous vous recommandons d utiliser des savons modernes pour obtenir les meilleurs r s...

Страница 23: ...charbon et coulement radial 7100640 OFPSP Cartouche antitartre 7100641 OFPCOM Offre combin e pr vention du tartre et bloc de charbon PI CES DE RECHANGE DU SYST ME ONEFLOW 7300759 OFPHSG Bo tier et t...

Страница 24: ...ine la plus proche sans frais l exclusion des frais de livraison et de main d uvre locale le cas ch ant Les dommages au m dia attribuables au chlore d autres comburants ou l encrassement provoqu par l...

Отзывы: