background image

6

OFPSYS EU_IOM_IT_W_UK_01_21_Rev0

Watts Water Technologies, Inc.

UK

The descriptions and photographs contained in this product specification sheet are supplied by way of information only and are not binding. Watts Industries reserves the right to carry 
out any technical and design improvements to its products without prior notice. Warranty: All sales and contracts for sale are expressly conditioned on the buyer’s assent to Watts terms 
and conditions found on its website at www.wattswater.eu. Watts hereby objects to any term, different from or additional to Watts terms, contained in any buyer communication in any 
form, unless agreed to in a writing signed by an officer of Watts.

4. Maintenance

4.1 

Changing the Filter Cartridges

1.  Turn off water at supply valve or at main valve to home.
2.  Use the Multifunction Tool (Item 6) to release air from the 

system. This is done by taking the tool and unscrewing the 
Pressure Relief Valve (Item 5) – refer Diagram F.

3.  Use Multifunction Tool (Item 6) to unscrew OneFlow

®

+ EU 

Head Assembly (Item 7) counterclockwise and remove from 
the OneFlow

®

+ EU Housing as shown in Diagram G.

4.   Remove Outlet Connector (Item 8 from top of OneFlow

®

+ EU 

Scale Reduction (TAC) Cartridge – refer Diagram D.

5.  Use Multifunction Tool (Item 6) to remove OneFlow

®

+ EU 

Scale reduction (TAC) cartridge (Item 10) from the Sediment/
Carbon Cartridge (Item 9) as shown in Diagram H.

6.  Remove the Sediment/Carbon (Item 9) from the OneFlow

®

EU Housing by hand.

7.   Remove new Sediment/Carbon cartridge from packaging and 

place carefully inside the OneFlow

®

+ EU Housing as shown 

in Diagram B.

8.   Insert  OneFlow

®

+ EU Scale Reduction (TAC) cartridge back 

into the center of the Sediment/Carbon cartridge making sure 
that it is sealed correctly as shown in Diagram C.

9.   Insert Outlet Connector (Item 8) into outlet port and secure 

back on top of the OneFlow

®

+ EU Scale Reduction cartridge 

as shown in Diagram D.

10.   Place Head Assembly back onto OneFlow

®

+ EU Housing 

and using the multifunction tool tighten by screwing 
the Head Assembly clockwise as shown in Diagram E. 
 
DO NOT OVER TIGHTEN

11.  Close the pressure relief valve by tightening in a counterclock-

wise direction as shown in Diagram F.

12.  Turn water supply on and check for leaks.

Notice

• 

 Where influent water pressure will at any time exceed 500 
kPa (70 psi) a suitable pressure limiting valve must be 
installed.

• 

Product performance is dependent upon influent water 
quality.

• 

The system must be installed and maintained in accord-
ance with the manufacturer’s instructions including replace-
ment of the filter cartridges.

• 

Please ensure all o-rings are well lubricated and clean from 
foreign particles.

CLOS E

OPEN

Diagram A

Diagram E

Diagram F

Diagram G

Diagram H

Diagram B

Diagram C

Diagram D

Содержание OneFlow OFPSYS EU

Страница 1: ...Watts Oneflow com OneFlow OFPSYS EU Innovative Scale Control Installation manual UK Installation and Operation Manual...

Страница 2: ...Failure to read and follow all safety and use information can result in serious personal injury property damage or damage to the equipment This manual contains important operation maintenance and prec...

Страница 3: ...hat requires protection from the ill effects of hard water OneFlow uses template assisted crystallization T A C to attract hardness minerals and convert them into harmless inactive microscopic crystal...

Страница 4: ...quires a lot of space to allow the media to fully fluidize The system has no underbed so you can tip the system over without any fear of upsetting the media This makes transportation and installation...

Страница 5: ...s shown in Diagram A 8 Place a bucket under the outlet port or run a line from the outlet port to a drain 9 Turn the water back on to the house Slowly open the supply valve to the OneFlow EU system Al...

Страница 6: ...OneFlow EU Scale reduction TAC cartridge Item 10 from the Sediment Carbon Cartridge Item 9 as shown in Diagram H 6 Remove the Sediment Carbon Item 9 from the OneFlow EU Housing by hand 7 Remove new S...

Страница 7: ...2 8 mm Min to 60 A F F Installation Height Side View 1 BSP Inlet Connection from water supply D B E A 65 09 mm 93 66 mm 7 94 mm 76 2 mm Min Removal Clearance Back View Dimensions Weights Model A B C D...

Страница 8: ...s terms to be found on www wattswater eu UK CONTACTS Austria Germany Switzerland Watts Industries Deutschland GmbH Godramsteiner Hauptstr 167 76829 Landau Germany tel 49 0 6341 9656 0 fax 49 0 6341 96...

Отзывы: