2.  System Specifications

Inlet/outlet connections:

 3⁄4” FNPT with BSP threaded fittings

Nominal flow rate OFPSYS:

 up to 38l/min

Flow capacity (continuous flow rate):

 up to 38l/min, 24/7/365 

for 2 years for the OFPSYS cartridge

Maximum pressure:

 90psi / 6.2 bar

Maximum temperature:

 38°C

Minimum temperature:

 5°C

Capacity:

  Elements present in the water will gradually degrade 

the effectiveness of the cartridge. Change the OPSYS cartridges 
at least once every two years.

A OneFlow

®

 Innovative Scale Control system shall be installed on 

the cold water service line to condition the tap water just prior to 
the service line feeding the equipment it is designed to protect. 
The system will be sized for maximum or peak flow rate based 
on the specification of said equipment. A OneFlow

®

 system may 

also be installed to protect multiple pieces of equipment from 
the ill-effects of hard water scale provided the aggregate peak 
flow rate for each piece of equipment it is protecting has been 
considered. The system shall be plumbed with a bypass valve to 
allow isolation of filter housing to allow the bypass of untreated 
water in the event that service or cartridge replacement be nec-
essary. Bypass is recommended but not required. The installa-
tion area should be suitable in size for the housing to be serviced 
without encumbrance. The OneFlow

®

 system does not require 

additional water to backwash, flush, or regenerate once put into 
service. The system shall not require any chemical additives and 
shall not require electricity for operation.

1. Introduction

The OneFlow

®

 Innovative Scale Control System provides 

protection from hard scale formation on internal plumbing 
surfaces. The OneFlow

®

 system is a single cartridge-based 

system that must be installed on a cold water line prior to a 
single water heating device (water heater or tankless water 
heater) that requires protection from the ill effects of hard water.
OneFlow

®

 uses template assisted crystallization (T.A.C.) to 

attract hardness minerals and convert them into harmless, 
inactive microscopic crystal particles. These crystals stay 
suspended in the water and are passed to drain. The system 
requires very little maintenance, no backwashing, no salt and 
no electricity. Typical hardness problems, especially build-up of 
scale in heating elements, pipes, water heaters, boilers are no 
longer a concern. OneFlow

®

 is not a water softener. It does not 

need additional chemicals. It is a hard scale prevention device 
with proven third party laboratory test data and years of suc-
cessful commercial, residential and foodservice applications. 
OneFlow

®

 is the intelligent scale solution and is a great alterna-

tive to water softening or scale sequestering devices.

OFPSYS EU

• 

Reduces sediment, chlorine taste and odor

• 

OneFlow

®

 converts hardness minerals to harmless, 

inactive microscopic crystals making OneFlow

®

 an effective 

alternative to water softeners

• 

Virtually maintenance free - No salt bags or other chemicals 
required

• 

No energy consumption (different compared to other scale 
control technologies)

• 

Contributes to reduce water and electric consumption, no 
control valve needed

• 

Innovative technology with an enhanced respect of the 
environment, salt free, without additional chemicals

• 

Improves efficiency of all water heating devices and down-
stream plumbing components

• 

Simple sizing & installation – standard 3/4” connections

• 

Perfect solution for homes where equipment protection 
is desired for longer equipment life and reduced energy 
consumption

• 

Inlet ball valve for easy isolation shutoff and filter changes

• 

OneFlow

®

 cartridge-based systems are easily maintained; 

change the TAC cartridge once every two years

• 

Mounting bracket and wrench for cartridge change-outs 
included

* Exceeding maximum flow can reduce effectiveness and void 
warranty. Pressure drop at peak flow rate is less than 1 bar at 
27°C feed water.
** This system is delivered with 3/4” MNPT x 3/4” MBSPT fit-
tings. The fitting marked with red should be connected to the 
inlet/outlet of the system.
*** See more information on our website: www.watts-oneflow.com

All these water chemistry requirements are corresponding to 
the average parameters of the water delivered usually, please 
contact your water supplier or local autorities in order to con-
firm the compliance.

2.1      Feed Water Chemistry Requirements

pH

6.5-8.5

Hardness (maximum)

427 mg/L CaCO3 (28,8°dH, 51,3°fH)*

Water Pressure

1 bar - 6.2 bar

Temperature

5°C - 38°C

Free Chlorine

<2 mg/l

Iron (maximum)

0.3 mg/l**

Manganese (maximum)

0.05 mg/l**

Copper

1.3 mg/l***

Oil & H2S

Must be Removed

Total Phosphates

< 3.0 mg/l

Silica (maximum)

20 mg/l

TDS

1500 mg/l

††

Содержание OneFlow OFPSYS EU

Страница 1: ...Watts Oneflow com OneFlow OFPSYS EU Innovative Scale Control Installation manual UK Installation and Operation Manual...

Страница 2: ...Failure to read and follow all safety and use information can result in serious personal injury property damage or damage to the equipment This manual contains important operation maintenance and prec...

Страница 3: ...hat requires protection from the ill effects of hard water OneFlow uses template assisted crystallization T A C to attract hardness minerals and convert them into harmless inactive microscopic crystal...

Страница 4: ...quires a lot of space to allow the media to fully fluidize The system has no underbed so you can tip the system over without any fear of upsetting the media This makes transportation and installation...

Страница 5: ...s shown in Diagram A 8 Place a bucket under the outlet port or run a line from the outlet port to a drain 9 Turn the water back on to the house Slowly open the supply valve to the OneFlow EU system Al...

Страница 6: ...OneFlow EU Scale reduction TAC cartridge Item 10 from the Sediment Carbon Cartridge Item 9 as shown in Diagram H 6 Remove the Sediment Carbon Item 9 from the OneFlow EU Housing by hand 7 Remove new S...

Страница 7: ...2 8 mm Min to 60 A F F Installation Height Side View 1 BSP Inlet Connection from water supply D B E A 65 09 mm 93 66 mm 7 94 mm 76 2 mm Min Removal Clearance Back View Dimensions Weights Model A B C D...

Страница 8: ...s terms to be found on www wattswater eu UK CONTACTS Austria Germany Switzerland Watts Industries Deutschland GmbH Godramsteiner Hauptstr 167 76829 Landau Germany tel 49 0 6341 9656 0 fax 49 0 6341 96...

Отзывы: