Specifications

Inlet Connection

2” PVC Union with Socket.

Outlet Connection 2” PVC Socket
Temperature

40° - 110°F

pH

6.5 to 8.5

Ferrous Iron, Max* 0.3 mg/L

Manganese, Max* 0.05 mg/L

Copper, Max*

1.3 mg/L

Water Pressure

15 min, 100 max (PSI)

Equipment Specifications

OneFlow

®

 systems are complete, self-contained, 

loaded with media, and ready to use. A simple 

inlet and outlet connection is all that is required 

for installation. Please review operating pressures, 

temperatures and water chemistry limitations to 

ensure compatibility.

Mechanical Specifications

MODEL

1465

1665

Dry Weight (lbs)

54

68

Service Weight (lbs)

350

420

Dimensions

(nominal - inches)

a

17

17

b

14

16

c*

79

79

d

65

65

e*

10.25

10.50

* The overall height and the height of the inlet fitting varies due 
to material variations and assembly tolerances. Please allow ad-
ditional clearance above the tank for making connections.

c

d

a

Installation 

Tighten the Tank Bushings

Lay the tank down and check the bushings 

on the inlet and outlet (bottom and top) of the 

tank. It is common for them to loosen during 

shipment. Tighten the bushings with a strap 

wrench as needed

Install Piping

Connect the inlet and outlet plumbing according to 

your preferences and any applicable local codes. 

Include sample/drain ports with hose-bibb con-

nections on the inlet and outlet piping to facilitate 

startup and service.

NOTE:

 We recommend the installation of a dual-union ball-valve 

on the inlet and outlet to isolate the tank for servicing.

NOTE:

 A full bypass should be installed so that the full service 

flow can be routed around the system as needed for servicing.

NOTE:

 The OneFlow

®

 system operates in the Up-Flow mode 

which is opposite of a conventional softener. The inlet is on the 

bottom, the outlet on the top.

Important Notes!

!

i

Support the Piping

The full weight of the piping and 

valves must be supported by uni-

strut, pipe hangers or other means. 

The tank connections cannot sup-

port the weight of the piping. This 

photo from a multi-tank system 

installation shows properly supported 

piping.

Tank bushing. 

Rotate Clockwise 

to tighten.

Start-Up

1

2

Connect a hose to the hose bibb on the 

outlet of the tank. Run the hose to a drain.
Slowly / partially open the supply water 

ball valve. Allow the tank to slowly fill with 

water. When a steady stream of water ap-

pears at the drain, close the supply valve.
Open the inlet and outlet valves on the 

system. Transfer the bypass valves from 

Bypass to the Service position. Open 

a nearby faucet downstream from the 

OneFlow

®

 system to relieve any air.

Check for leaks. Repair as needed.
The system is now ready for service.

MaximumServiceFlow(gpm)vs.Water
Temperature
ContinuousDutySystems:

System

40°F

45°F

50°F

55°F

60°F

65°F

70°F

14-65

40

44

48

50

50

50

50

16-65

45

51

56

59

63

69

75

IntermittentDutySystems:

14-65

50 GPM at all temperatures

16-65

75 GPM at all temperatures

* Intermittent duty is defined as less than 2 hours of Maximum 

Flow per 24 hour period. Higher Flow rates can be achieved by 

combining systems in an array.

e

b

Содержание OF1465

Страница 1: ... chemistry e g antiscalants sequestrants etc will most likely have to be changed to be compatible with OneFlow treated water Laundry and ware washing chemistry will likewise require adjustments OneFlow Benefits Chemical free scale prevention Cost savings and environmental benefits Virtually maintenance free No salt bags or other chemicals to buy transport and store No electricity no wastewater com...

Страница 2: ...ow system in bypass prior to following the startup procedure and flush the plumbing for at least 10 minutes Cautions Do not let the system freeze Damage to the tank may result System must be operated in a vertical position Do not lay it down during operation The system may be placed in any position for shipping and installation but must be operated in the vertical position Place the system on a sm...

Страница 3: ...l valve on the inlet and outlet to isolate the tank for servicing NOTE A full bypass should be installed so that the full service flow can be routed around the system as needed for servicing NOTE The OneFlow system operates in the Up Flow mode which is opposite of a conventional softener The inlet is on the bottom the outlet on the top Important Notes i Support the Piping The full weight of the pi...

Страница 4: ...ty period stated above Such replacement parts will be delivered to the owner F O B nearest factory at no cost excluding freight and local labor charges if any Our obligation under this warranty with respect to the OneFlow media will be limited to furnishing a replacement for the media within two years from date of original installation Such replacement media will be delivered to the owner F O B ne...

Страница 5: ...or ejemplo inhibidores de sarro secuestrantes etc para que sean compatibles con el agua tratada con OneFlow Los químicos utilizados para el lavado de ropa y piezas también necesitarán ciertos ajustes Ventajas de OneFlow Prevención de sarro sin sustancias químicas Permite ahorrar costos y beneficiar al medio ambiente Prácticamente no necesita mantenimiento No se necesita comprar transportar ni alma...

Страница 6: ...vertencias No permitir que el sistema se congele El depósito podría dañarse El sistema debe funcionar en posición vertical No colocarlo en posición horizontal durante su funcionamiento El sistema puede ubicarse de cualquier posición para el transporte y la instalación pero durante su funcionamiento debe estar en posición vertical Colocar el sistema en una superficie lisa y plana Debido a que el si...

Страница 7: ...derivación total para que el caudal de servicio total pueda dirigirse en el sistema del modo en que sea necesario para el mantenimiento NOTA El sistema OneFlow funciona en el modo de caudal ascendente a diferencia de un ablandador convencional La entrada se encuentra en la parte inferior la salida en la parte superior Avisos importantes i Sujetar la cañería El peso total de la cañería y las válvul...

Страница 8: ...ía antes estipulado Tales piezas de repuesto serán entregadas al propietario bajo condición Libre a bordo Free on Board FOB en la fábrica más cercana sin costo alguno sin incluir gastos de flete y mano de obra local de corresponder Nuestra obligación bajo la presente garantía con respecto al material OneFlow estará limitada a suministrar repuestos por el material durante dos años desde la fecha de...

Страница 9: ...evra très pro bablement être modifiée pour être compatible avec l eau traitée avec le système OneFlow La chimie de lavage des vêtements et de la vaisselle devra également être modifiée Avantages du système OneFlow Prévention contre le tartre sans produits chimiques Économies et respect de l environnement Pratiquement sans entretien Pas de sacs de sel ou d autres produits chimiques à acheter transp...

Страница 10: ...r Ceci pourrait endommager le réservoir Le système doit être utilisé à la verticale Ne pas l allonger durant le fonctionnement Le système peut être placé dans n importe quelle position pour l expédition et l installation mais il doit être utilisé en posi tion verticale Placer le système sur une surface lisse et plate Puisque le système fonctionne en mode de débit ascendant à lit fluidisé l install...

Страница 11: ... installée pour que la totalité du débit de service puisse être acheminée autour du système selon les exigences de l entretien REMARQUE Le système OneFlow fonctionne en mode de débit ascendant à l opposé d un adoucisseur conventionnel L entrée est situé en bas la sortie en haut Remarques importantes i Support de la tuyauterie Le poids total de la tuyauterie et des robi nets doit être supporté par ...

Страница 12: ...AB à l usine la plus proche à l exception des frais de transport et de main d œuvre locale le cas échéant Notre obligation dans le cadre de cette garantie par rapport au média filtrant OneFlow sera limitée à son remplacement dans les deux années suivant la date d installation d origine Le média filtrant de rechange sera fourni gratuitement au propriétaire FAB à l usine la plus proche à l exception...

Отзывы: