How can you create or change a user’s program (U1 or U2).
Before, select one of the user’s program U1 or U2 by using
and
.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
To program the remaining days, repeat step «
4
» to«
14
» and this for all the days of the week.
Once you have run through the whole programming, you only have to put the thermostat in the
mode.
•
To leave the program mode
without saving press many times the
key.
•
In program mode
you have the possibility to reset a user program separately (
U1
or
U2
)
o
Choose the program to be cleared, then press
(the program number must be blink) now press the
key during a 10 seconds.
•
When the program is cleared
CLr U_
is displayed.
Temperature of the
step
Starting hour
of the step
Finishing hour of
the step
Number of steps
during the day
Days of the week
Select the
days to be
programmed
Adjust the
temperature
of the first
step
or
Adjust the
Final hour of
the second
step
or
or
or
Adjust the
temperature of
the second
step
or
Use the keys
and
to change the mode
WARM or COLD mode
Choose the desired function by using
«
Mod Hot
» to control a heating system
«
Mod Cold
» to control a cooling system
HOLIDAYS mode
Use this function during a long absence
Use the keys
and
to blink the value and modify with
and
:
-
The duration in hours «
H
» when it’s less than 24 h or in days «
d
».
-
The desired temperature for this period (default setting 6°C)
To leave the HOLIDAYS mode, set duration on «
no
».
COMFORT mode
Use this function to set your installation in comfort mode.
Use the keys
and
to adjust the comfort temperature. The
Comfort
temperature will be followed.
Push the
to view the current setting temperature (default setting 21°C)
AUTO mode
The thermostat follows the chosen program in accordance with the actual hour.
By using the
and
keys, you can adapt the
temperature until the next change within the program. The symbol
is displayed. Push the
to view the current setting
temperature, the temperature and the starting hour for the next program step)
REDUCED mode
Use this function to put your installation in “reduced temperature mode”.
Use the
and
keys to adjust the
reduced
temperature. The
reduced
temperature will be followed.
Push the
to view the current setting temperature (default setting 17°C)
ANTI-FREEZE mode
Use this function if you want to protect your installation against frost.
Use the
and
keys to adjust the anti-freeze temperature. The «
Anti-freeze
» temperature will be followed.
Push the
for an instantaneous adjustment display (default setting 6°C)
CLOCK ADJUSTEMENT mode
1/
Press
: The hour’s blinks, then you can adjust it with
and
keys
2/
Press
: The minute’s blinks, then you can adjust it with
and
keys
3/
Press
: The current day of the week blinks, then you can adjust it with
and
keys (1 = Monday)
4/
Press
: To valid your adjustment.
OFF mode
Use this function to switch off your installation.
The program’s version is displayed during 5 seconds before the thermostat is definitely switched off.
Press 1 of the keys to restart the thermostat.
PROGRAMME mode
Push the
key: the number of the current program blinks. You can choose a program by using
and
.
- By pressing the
key, you can display the program in case of a built-in program (
P1
to
P5
) or you can create or adapt
a user’s program (
U1
and
U2
).
- The built-in program operates between the temperatures «
comfort
» and «
reduced
».
Built-in programs descriptions.
P1:
Morning, evening & weekend
P3:
7h - 19h (office))
Evening & weekend
P5:
8h - 19h, Saturday (Shop)
P2:
Morning, noon, evening & weekend
P4:
Week-end (Secondary House)
Keyboard lock and unlock function.
In the
,
,
,
,
,
modes, you can lock the keyboard, by
pressing
key continuously and press
at the same time.
Then the symbol
appears. To unlock the keyboard repeat this operation. (
disappears)
FUNCTION MODES DESCRIPTION
or
or
Adjust the
Final hour of
the first
step
End of the day
Program the remaining days