Lync WQ-AS
SECTION 1: INTRODUCTION
L- OMM-007_A
•
5/6/2022
Technical Support • (800) 433-5654 • Mon-Fri, 8 am - 5 pm EST
7
of
42
Max nominal electrical power for each lamp (Watts)
112
Lamp technology
Quartz glass low pressure lamp / ozone free / true
pre-heat starting / glow-cap indicator
Wireless lamp key
Standard
Lamp dimming / Flow switch
Standard
System display type
Color Touch Screen with multiple languages,
intuitive screen navigation, detailed system status
messages, maintenance/diagnostic, and dealer
programmable with website/contact
information/QR codes
UV Sensor
Yes
Lamp life monitor
Display on graphic touch screen, auto-reset with
new lamp
Visual alarm
Animated icons and text messages on graphic
display
Audible alarm / audible alarm mute
Yes / yes
Alarm relay / Solenoid contacts
Yes / 24V 5 Amp Maximum
Alarm relay manual over-ride
Yes
Lync Cartridge Filter
Lync Cartridge Filter size
5 micron
Material, filter body & cartridge end caps
Glass reinforced PP
Brass reinforced gauge port
1⁄4" FNPT
Material, swing bolts
304SS
O-ring
EPDM
Lid closure
Swing bolt
Pipe fittings (One inlet and two outlets) PVC
2" SLIP Female PVC
Drain
1⁄2" FNPS with drain plug
Cartridge change-out, sediment
15 psi differential (max.)
AquaSolve
Flow rate per AquaSolve system
50 gpm
Standard NPT inlet / outlet ports
2" NPT-F / 2"NPT-F
WARNINGS!
• Not for use on closed loop systems.
• Do not let the system freeze. Damage to the tank may result.
• Place the WQAS skid on level surface. Because the system operates in an up-flow,
fluidized bed mode, having a level surface is more important than with a softener or
media filter.
• A bypass valve should be installed before and after the skid to facilitate installation and
service.
• Observe all local plumbing and building codes when installing the system.
• Do not apply any other anti-scalants before or after WQAS skid.