SECTION 9: LYNC UV-H LIMITED WARRANTY  

    

 

SECTION 9: LYNC UV-H LIMITED WARRANTY 

Limited Warranty for LYNC UV-H Ultraviolet Water Disinfection Systems purchased in Canada, the 
United States, Australia and New Zealand only. For systems purchased outside of North America, the 
original manufacturer

’s warranty (available at: www.uvpure.com/warranty/) may provide additional 

coverage for system components manufactured by UV Pure Technologies. Please see the manufacturer

’s 

warranty for additional details.  

What this warranty covers: 

Defects in materials and workmanship in systems sold by Lync by Watts including Hallett

®

 systems, 

replacement UV lamps and other original equipment manufacturer components such as manifolds or 
NEMA cabinets sold or certified by Lync by Watts. 

What the period of coverage is for System Parts: 

Five-year Limited Warranty for structural, hardware, and mechanical components. Specifically, this 
includes the following system parts: system casing (machined and extruded aluminum parts, stainless 
steel parts, and plastic molded components), stainless steel manifolds, NEMA cabinets, welded steel 
skids and structural components, and stainless steel self-cleaning mechanism. 

Three-year Limited Warranty for electrical components, reflectors, and quartz sleeve. Specifically, this 
includes the following system parts: wiper motor, air blowers, circuit boards, ballast and micro-
processor with digital display, wiring harnesses, lamp sockets, reflectors, and quartz sleeves. 

One-year Limited Warranty sensor probes and purge valves. Specifically this includes the following 
system parts: UV sensors and the circuit board they are mounted in, temperature probes, and purge 
valves.    

12-month Limited Warranty for all replacement LPHO lamps (coverage applies up to two years from 
the date of manufacture of the lamps). 

16-month Limited Warranty for all replacement amalgam lamps 

Ninety-day Limited Warranty or Balance of Original Warranty for replacement Parts. Specifically this 
includes any system parts replaced or repaired under this Limited Warranty. This warranty period is for 
the balance of the original warranty or for 90 days from the date the Part is repaired and/or returned to 
the first end-user whichever is longer. An exception is all replacement lamps that are covered for 12 or 
16 months from date of replacement depending on lamp type. 

Who is covered: 

This Limited Warranty extends to you only if you are the FIRST END-USER PURCHASER and with respect 
to the ORIGINAL INSTALLATION; 

the warranty period shall commence upon the Date of Purchase. 

What we will do to correct problems covered by this Limited Warranty: 

During the warranty period, as set out above, Lync by Watts will repair or replace Products or Parts, at 
its sole discretion and cost, with the exception of shipping and handling charges. Lync by Watts may 
require that certain failed part be returned to Lync by Watts within 45 days for analysis and to facilitate 
continuous improvement; for example, circuit boards and sensors that fail must be returned to Lync by 
Watts. Replacement parts or systems may be functionally equivalent reconditioned/refurbished/pre-
owned or new products or parts at Lync by Watts

’ sole discretion. Lync by Watts may provide software 

updates, at its discretion, but is under no obligation to do so.  

How to get help: 

Call a Lync by Watts representative. A complete list of representatives and their coverage areas is 
available on Lync by Watts

’s website: www.LyncbyWatts.com.   

 

 

Содержание LYNC UV-H

Страница 1: ...L OMM 016_A 6 22 2023...

Страница 2: ...rt Stop 14 4 8 4 20mA Modbus Option 14 4 9 Data Logging on USB Option 15 SECTION 5 OPERATING INSTRUCTIONS 16 5 1 Unit Functions 16 5 2 Navigating the Menus 17 5 3 Plugging in the UV H for the first ti...

Страница 3: ...the product meet IEC 60335 1 IEC 60335 2 109 National Differences EU Group Differences AU NZ SG and are CE and ACMA Australian Communications Media Authority compliant NSW CS11052N The Hallett 500PN...

Страница 4: ...the event the chamber is accessed when the power is on Do not defeat its purpose or attempt to service without opening the panel completely 10 Do not operate the unit with a damaged cord or plug or a...

Страница 5: ...s for 120Vac 1 3Safety Symbols WARNING Potential Shock Hazard Shutdown and unplug the unit before servicing DANGER UltravioletRadiation Disconnectpower beforereplacing lamps Thelampsintheunit emit ult...

Страница 6: ...pertocleantheinsideofthe quartz sleeve eliminating fouling and the need for a water softener making abrasive quartz sleeve cleaning a thing of the past saving money and the environment The wiper is au...

Страница 7: ...gpm 40 gpm 16 5 gpm 37 gpm Performance Certifications 2 NSF ANSI 55 Class A NSF ANSI55Class A Min UVT for 40mJ cm2 Dose 95 75 95 75 95 Flow Restrictor Optional Yes Optional Yes Optional Pressure Drop...

Страница 8: ...us connectivity Optional Optional Optional Optional Optional Optional Power Draw 403W 403W 222W 222W 196W 196W Inlet Outlet Port size 2 MNPT 2 MNPT 1 MNPT 1 MNPT 1 MNPT 1 MNPT Nominal Dimensions H x W...

Страница 9: ...less than or equal to 1000 mg L mg L ppm Level of turbidity or cloudiness of less than or equal to 1 NTU nephelometric turbidityunit In a point of entry application a 5 micron sediment filter is recom...

Страница 10: ...e discharge line WARNING Use copper or stainless steel pipingattheUVoutletsincewatertemperaturescanreach176 F 80 C if the UV unit operates without water flow or the ability to purge DO NOT USE PVC The...

Страница 11: ...re treatment devices such as filters water softeners etc and also any pressure tanks However it must be installed before any branches in the piping so that all the water is disinfected before splittin...

Страница 12: ...ough Lync by Watts Use only new hoses old hoses should be discarded Ifhosesare being used connect them now to both the top and bottom of the unit Make sure that the sealing washer is inside the hose e...

Страница 13: ...al operation always leave valve in automatic position In the Advanced Settings menu item 2 7 3 toggle the valve to be Installed and a monthly reminder will appear to test valve Please test valve month...

Страница 14: ...is treating if the contact is open the unit is in alarm has lost power or perhaps the wire has been cut The second contact labeled WARNING is to indicate the existence of an abnormal condition such a...

Страница 15: ...NS 4 9 Data Logging on USB Option Data logging capability is an available option on all UV H units A small USB drive is used to record system performance every 30 seconds The USB drive can store up to...

Страница 16: ...Green Light an illuminated green light indicates the unit is treating normally A slow flashing green light means the UV lamps are not yet at full power or the unit is in standby mode awaiting a remote...

Страница 17: ...tact Info Text Company Phone Installation date 1 System Info 1 1 UVT 1 2 UVI 1 3 Left Lamp UV 1 4 Left Water UV 1 5 Right Lamp UV If available 1 6 Right Water UV If available 1 7 PCB Temp 1 8 Sys Temp...

Страница 18: ...etric 2 5 Reset Lamp Counter 2 6 Message History Last 100 messages 2 6 1 Message 1 2 6 1 1 UV Dose 2 6 1 2 Water Temp 2 6 1 3 Estimated UVI 2 6 1 4 Estimated UVT 2 6 1 5 Left Lamp UV 2 6 1 6 Left Wate...

Страница 19: ...3 Interlock for UV door 2 7 1 14 Wiper Positioner switch 2 7 1 15 Remote Start Stop Signal 2 7 1 16 Fault 1 2 7 1 17 Fault 2 2 7 1 18 Lamp Temp 2 7 1 19 Water Temp 2 7 1 20 Analog In 2 7 1 21 System T...

Страница 20: ...onents In the event of a lack of water or water supply being turned off shutdown the unit until the water supply can be restored In the event of a power failure the unit will shut down and the optiona...

Страница 21: ...ost filters if installed also require flushing prior to use follow the manufacturer s recommendations The system may be flushed manually by disassembling the unit and filling and draining the unit by...

Страница 22: ...idual especially in the case of discharge into a septic system 8 Now that the disinfection procedure is complete you will need to return the filter to its housing Shut off the water supply relieve wat...

Страница 23: ...bleshooting since it contains up to 100 messages events with associated recordeddatasuchastimes UVI UVT UVsensor values and temperatures In the event of an alarm in many cases a physical inspection of...

Страница 24: ...etime Replace lamps of lamp starts have exceeded specification Replace lamps but reduce future lamp cycles UV sensor requires recalibration replacement Install reference sensor to confirm status of un...

Страница 25: ...riodically The UV H contains a washable air filter in the located at the air inlet port See Figure 7 1 Periodically check and clean the filter to ensure blower operation is not impeded Figure 7 1 UV S...

Страница 26: ...down the system for seasonal use will extend lamp life The unit has an internal timer to keep track of the lifetime of the lamps The UV H will issue a warning when the end of lamp lifetime approaches...

Страница 27: ...ng and waste management authority for proper disposal procedures in your area Figure 7 3 Figure 7 4 5 Install the new lamps into the unit one at a time being careful not to touch the bulb Insert the t...

Страница 28: ...nit to collect the water 4 Open a tap downstream of the unit to vent 5 Open the optional drain valve if installed and disconnect the flexible hose or piping at the bottom port to allow the system to d...

Страница 29: ...out afterwards Fill the rest of the quartz sleeve with water 8 Let the cleaning solution remain in the quartz sleeve for at least 10 20 minutes 9 Manually turning the wiper may greatly assist the clea...

Страница 30: ...alsobehandledwithcaretopreventdamagetocleaning edges The wiper blades are sharp handle them with care Figure 7 6 10 Remove the retaining ring E ring holding the wiper shaft 11 Use the 7 16 11mm wrench...

Страница 31: ...t is placed onahorizontal surface removing the unit from the wall to work on a bench is recommended especially for the UV H Hallett 1000 models Figure 7 7 5 Remove the bottom plastic cover and then th...

Страница 32: ...ct for leaks Repair any leaks if necessary before plugging in the unit 6 Reinstall the motor mounting plate by using the trigger cam to center the plate center hole to be concentric with wiper shaft W...

Страница 33: ...LYNC UV H SECTION 7 MAINTENANCE Figure 7 9A...

Страница 34: ...LYNC UV H SECTION 7 MAINTENANCE Figure 7 9B...

Страница 35: ...s 3 15A 250V 5x20mm IEC 12 Seal Kit complete GD5 2 Port GD6 1 port 13 Air Filter GD7 14 UV Chamber Blower Kit GD8 15 Circuit Board Blower Kit GD9 16 Temperature Sensor Thermistor Kit GD10 3 per unit 1...

Страница 36: ...LYNC UV H SECTION 8 SERVICE RECORD SHEET SECTION 8 SERVICE RECORD SHEET Record lamp replacement dates and events in the space provided below Date MMM DD YYYY Action System Installed...

Страница 37: ...mounted in temperature probes and purge valves 12 month Limited Warranty for all replacement LPHO lamps coverage applies up to two years from the date of manufacture of the lamps 16 month Limited War...

Страница 38: ...s that are improperly installed used and or not maintained as set out in this IOM or as expressly advised by Lync by Watts This Limited Warranty does not cover damage caused by accidents acts of God m...

Страница 39: ...is intended to be installed on visually clear water NSF ANSI 55 defines wastewater to include human and or animal body waste toilet paper and any other material intended to be deposited in a receptac...

Страница 40: ...ION 10 NSF STATEMENT Change Log Date Description Changed By 3 1 2023 Added branded Lync cover and formatted to Lync standards Lisa Weiss 6 22 23 Multiple edits re certification and specifications via...

Отзывы: