LYNC UV-H 

SECTION 7: MAINTENANCE  

    

 

7.6 In-place Cleaning 

This procedure will clean the quartz sleeve without its removal from the unit. This is a quick and easy 
procedure that works well in most cases.  

Tools Needed: 

slotted screwdriver

Phillips screwdriver

pipe wrench.

 

1.  Fill a bucket or container with 1 gallon (4 liters) of clean water - this will be required later to clean 

the quartz sleeve. A squeeze bottle is useful for applying water or cleaning solution to the inside of 
the quartz sleeve. 

2.  Shutdown and unplug the unit. 

3.  Shut off the water supply and relieve the pressure. 

4.  Open the UV Chamber as described in Accessing UV Chamber section. 

5.  Place another bucket under the unit and drain the unit until there is about 1

” (3cm) of water left in 

the quartz sleeve (see Draining the Unit section). 

6.  Disconnect the fitting at the top outlet port of the UV unit. If the stainless flexible hose was 

installed, disconnect the hose opposite from the UV unit then bend the open end upwards 

– this will 

make the next step easier. 

7.  Add about 2 oz. (60cc) of cleaning solution to the top hose/manifold. The cleaning solution can be a 

citric acid, vinegar or other non-hazardous solutions. Any solution used should be thoroughly rinsed 
out afterwards. Fill the rest of the quartz sleeve with water. 

8.  Let the cleaning solution remain in the quartz sleeve for at least 10-20 minutes.  

9.  Manually turning the wiper may greatly assist the cleaning process. To do this, remove the top 

plastic cover then remove the motor and turn the wiper shaft with a slotted screwdriver 
(counterclockwise while looking at the shaft). If the optional wiper positioner switch is installed, 
leave the trigger cam in place. 

10. Drain the unit and inspect the quartz sleeve. If clean, flush the unit with clean water. If fouling 

remains, repeat procedure or proceed to disassembling the unit. 

11. Once the unit is clean, reassemble the system including the motor, plastic cover, top port 

connection(s) and UV chamber door. 

12. Slowly open the water supply and check for leaks. 

13. Restart the unit by plugging it in. 

 

7.7 Disassembling the Unit 

NOTE:

 This procedure is not recommended for untrained users - please contact your certified 

water specialist to assist should disassembly be required.   

Tools Needed: 

  slotted screwdriver 

  Philips screwdriver 

  Pipe wrench 

  7/16

” (11mm) wrench or nut driver 

  Bottle clean brush with long handle

1.  Fill a bucket with 1 gallon (4L) of clean water, required later to clean the quartz sleeve. A squeeze 

bottle is useful for applying water or cleaning solution to the inside of the sleeve. 

2.  Shutdown and unplug the unit. 

3.  Shut off the water supply and relieve the pressure. 

Содержание LYNC UV-H

Страница 1: ...L OMM 016_A 6 22 2023...

Страница 2: ...rt Stop 14 4 8 4 20mA Modbus Option 14 4 9 Data Logging on USB Option 15 SECTION 5 OPERATING INSTRUCTIONS 16 5 1 Unit Functions 16 5 2 Navigating the Menus 17 5 3 Plugging in the UV H for the first ti...

Страница 3: ...the product meet IEC 60335 1 IEC 60335 2 109 National Differences EU Group Differences AU NZ SG and are CE and ACMA Australian Communications Media Authority compliant NSW CS11052N The Hallett 500PN...

Страница 4: ...the event the chamber is accessed when the power is on Do not defeat its purpose or attempt to service without opening the panel completely 10 Do not operate the unit with a damaged cord or plug or a...

Страница 5: ...s for 120Vac 1 3Safety Symbols WARNING Potential Shock Hazard Shutdown and unplug the unit before servicing DANGER UltravioletRadiation Disconnectpower beforereplacing lamps Thelampsintheunit emit ult...

Страница 6: ...pertocleantheinsideofthe quartz sleeve eliminating fouling and the need for a water softener making abrasive quartz sleeve cleaning a thing of the past saving money and the environment The wiper is au...

Страница 7: ...gpm 40 gpm 16 5 gpm 37 gpm Performance Certifications 2 NSF ANSI 55 Class A NSF ANSI55Class A Min UVT for 40mJ cm2 Dose 95 75 95 75 95 Flow Restrictor Optional Yes Optional Yes Optional Pressure Drop...

Страница 8: ...us connectivity Optional Optional Optional Optional Optional Optional Power Draw 403W 403W 222W 222W 196W 196W Inlet Outlet Port size 2 MNPT 2 MNPT 1 MNPT 1 MNPT 1 MNPT 1 MNPT Nominal Dimensions H x W...

Страница 9: ...less than or equal to 1000 mg L mg L ppm Level of turbidity or cloudiness of less than or equal to 1 NTU nephelometric turbidityunit In a point of entry application a 5 micron sediment filter is recom...

Страница 10: ...e discharge line WARNING Use copper or stainless steel pipingattheUVoutletsincewatertemperaturescanreach176 F 80 C if the UV unit operates without water flow or the ability to purge DO NOT USE PVC The...

Страница 11: ...re treatment devices such as filters water softeners etc and also any pressure tanks However it must be installed before any branches in the piping so that all the water is disinfected before splittin...

Страница 12: ...ough Lync by Watts Use only new hoses old hoses should be discarded Ifhosesare being used connect them now to both the top and bottom of the unit Make sure that the sealing washer is inside the hose e...

Страница 13: ...al operation always leave valve in automatic position In the Advanced Settings menu item 2 7 3 toggle the valve to be Installed and a monthly reminder will appear to test valve Please test valve month...

Страница 14: ...is treating if the contact is open the unit is in alarm has lost power or perhaps the wire has been cut The second contact labeled WARNING is to indicate the existence of an abnormal condition such a...

Страница 15: ...NS 4 9 Data Logging on USB Option Data logging capability is an available option on all UV H units A small USB drive is used to record system performance every 30 seconds The USB drive can store up to...

Страница 16: ...Green Light an illuminated green light indicates the unit is treating normally A slow flashing green light means the UV lamps are not yet at full power or the unit is in standby mode awaiting a remote...

Страница 17: ...tact Info Text Company Phone Installation date 1 System Info 1 1 UVT 1 2 UVI 1 3 Left Lamp UV 1 4 Left Water UV 1 5 Right Lamp UV If available 1 6 Right Water UV If available 1 7 PCB Temp 1 8 Sys Temp...

Страница 18: ...etric 2 5 Reset Lamp Counter 2 6 Message History Last 100 messages 2 6 1 Message 1 2 6 1 1 UV Dose 2 6 1 2 Water Temp 2 6 1 3 Estimated UVI 2 6 1 4 Estimated UVT 2 6 1 5 Left Lamp UV 2 6 1 6 Left Wate...

Страница 19: ...3 Interlock for UV door 2 7 1 14 Wiper Positioner switch 2 7 1 15 Remote Start Stop Signal 2 7 1 16 Fault 1 2 7 1 17 Fault 2 2 7 1 18 Lamp Temp 2 7 1 19 Water Temp 2 7 1 20 Analog In 2 7 1 21 System T...

Страница 20: ...onents In the event of a lack of water or water supply being turned off shutdown the unit until the water supply can be restored In the event of a power failure the unit will shut down and the optiona...

Страница 21: ...ost filters if installed also require flushing prior to use follow the manufacturer s recommendations The system may be flushed manually by disassembling the unit and filling and draining the unit by...

Страница 22: ...idual especially in the case of discharge into a septic system 8 Now that the disinfection procedure is complete you will need to return the filter to its housing Shut off the water supply relieve wat...

Страница 23: ...bleshooting since it contains up to 100 messages events with associated recordeddatasuchastimes UVI UVT UVsensor values and temperatures In the event of an alarm in many cases a physical inspection of...

Страница 24: ...etime Replace lamps of lamp starts have exceeded specification Replace lamps but reduce future lamp cycles UV sensor requires recalibration replacement Install reference sensor to confirm status of un...

Страница 25: ...riodically The UV H contains a washable air filter in the located at the air inlet port See Figure 7 1 Periodically check and clean the filter to ensure blower operation is not impeded Figure 7 1 UV S...

Страница 26: ...down the system for seasonal use will extend lamp life The unit has an internal timer to keep track of the lifetime of the lamps The UV H will issue a warning when the end of lamp lifetime approaches...

Страница 27: ...ng and waste management authority for proper disposal procedures in your area Figure 7 3 Figure 7 4 5 Install the new lamps into the unit one at a time being careful not to touch the bulb Insert the t...

Страница 28: ...nit to collect the water 4 Open a tap downstream of the unit to vent 5 Open the optional drain valve if installed and disconnect the flexible hose or piping at the bottom port to allow the system to d...

Страница 29: ...out afterwards Fill the rest of the quartz sleeve with water 8 Let the cleaning solution remain in the quartz sleeve for at least 10 20 minutes 9 Manually turning the wiper may greatly assist the clea...

Страница 30: ...alsobehandledwithcaretopreventdamagetocleaning edges The wiper blades are sharp handle them with care Figure 7 6 10 Remove the retaining ring E ring holding the wiper shaft 11 Use the 7 16 11mm wrench...

Страница 31: ...t is placed onahorizontal surface removing the unit from the wall to work on a bench is recommended especially for the UV H Hallett 1000 models Figure 7 7 5 Remove the bottom plastic cover and then th...

Страница 32: ...ct for leaks Repair any leaks if necessary before plugging in the unit 6 Reinstall the motor mounting plate by using the trigger cam to center the plate center hole to be concentric with wiper shaft W...

Страница 33: ...LYNC UV H SECTION 7 MAINTENANCE Figure 7 9A...

Страница 34: ...LYNC UV H SECTION 7 MAINTENANCE Figure 7 9B...

Страница 35: ...s 3 15A 250V 5x20mm IEC 12 Seal Kit complete GD5 2 Port GD6 1 port 13 Air Filter GD7 14 UV Chamber Blower Kit GD8 15 Circuit Board Blower Kit GD9 16 Temperature Sensor Thermistor Kit GD10 3 per unit 1...

Страница 36: ...LYNC UV H SECTION 8 SERVICE RECORD SHEET SECTION 8 SERVICE RECORD SHEET Record lamp replacement dates and events in the space provided below Date MMM DD YYYY Action System Installed...

Страница 37: ...mounted in temperature probes and purge valves 12 month Limited Warranty for all replacement LPHO lamps coverage applies up to two years from the date of manufacture of the lamps 16 month Limited War...

Страница 38: ...s that are improperly installed used and or not maintained as set out in this IOM or as expressly advised by Lync by Watts This Limited Warranty does not cover damage caused by accidents acts of God m...

Страница 39: ...is intended to be installed on visually clear water NSF ANSI 55 defines wastewater to include human and or animal body waste toilet paper and any other material intended to be deposited in a receptac...

Страница 40: ...ION 10 NSF STATEMENT Change Log Date Description Changed By 3 1 2023 Added branded Lync cover and formatted to Lync standards Lisa Weiss 6 22 23 Multiple edits re certification and specifications via...

Отзывы: