background image

 

 

Page 16 of 18 

 

WARRANTY 

 

 

WHAT YOUR WARRANTY COVERS: 
 

If any part of your Watts Pure Water Treatment Device is defective in workmanship (excluding replacement filter elements), return the 
unit within 1 year of date of original purchase. Watts will repair or, at WATTS option, replace it at no charge. 

 
HOW TO OBTAIN WARRANTY SERVICE: 

 
Contact WATTS  customer service department (1-888-774-7405) to obtain a Return Goods Authorization Number (RGA#).  Model and 

Serial Number are required for obtaining an RGA #.  For warranty service, ship your water treatment device with the RGA # printed on 
the Shipping Label to Watts, freight and insurance prepaid, with proof of original purchase date.  Watts will repair or replace the water 

treatment device and ship it back to you prepaid. 
 

WHAT YOUR WARRANTY DOES NOT COVER: 
 

This warranty does not cover defects resulting from improper installation, customer abuse, misuse, misapplication, improper 
maintenance, neglect, alteration, accidents, casualties, fire, flood, freezing, heat, environmental factors or acts of nature.  

 
This warranty will be voided if defects occur due to failure to observe the following conditions:   

 

1. The water treatment device must be hooked up to a potable municipal water supply. 

 

2. The pH of incoming water must not be lower than 6.0 or higher than 8.5. 

 

3. The incoming water pressure must be between 25 psi and 80 psi.   If water pressure exceeds 80 psi a pressure regulator 

must be      installed. 

 

4. Incoming water temperature cannot exceed 100

°

 F (40

°

 C). 

 

This warranty does not cover any equipment that has been relocated from the site of its original installation. 
  

This warranty does not cover equipment that is installed outside North America. 
 

LIMITATIONS AND EXCLUSIONS: 
 

Watts WILL NOT BE RESPONSIBLE FOR ANY IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE. 

 
WATTS WILL NOT BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING TRAVEL EXPENSES, 

TELEPHONE CHARGES, LOSS OF REVENUE, LOSS OF T IME, INCONVENIENCE, LOSS OF USE OF THE EQUIPMENT, AND DAMAGES 
CAUSED BY THE EQUIPMENT AND ITS FAILURE TO FUCTION PROPERLY. 

 

THIS WARRANTY SETS FORTH ALL OF WATTS’S RESPONSIBILITIES REGARDING THIS EQUIPMENT. 
 

OTHER CONDITIONS: IF Watts chooses t o replace the equipment, Watts may replace it with reconditioned equipment.   Parts used in 
repairing or replacing the equipment will be warranted for 90 days from the date the equipment is returned to you or for the remainder 

of the original warranty period, whichever is longer.   This warranty is not assignable or transferable.  
 

YOUR RIGHTS UNDER STATE LAW: 
Some states do not allow limitations on how long an implied warranty lasts and some states do not allow the exclusion or limitation of 

incidental or consequential damages, so the above limitations or exclusions may not apply to you.  This warranty gives you specific 
legal rights. You may have other legal rights, which vary from state to state. 

 

 
 

 

 
 

Содержание HS Series

Страница 1: ...Page 1 of 18 HS Series Reverse Osmosis Processor With Built in Pre treatment and Membrane Flush HS Series Pressure Tank Float Tank Models Installation Operation Maintenance Manual...

Страница 2: ...ing Watts HS Series Reverse Osmosis system read this manual completely Keep this manual available for future reference Further information is available by contacting your local Watts distributor Phone...

Страница 3: ...ion Membrane installation 5 Inlet Connection 6 Permeate Line Connection 7 Pressure Tank Connection 8 Atmospheric Storage Tank 9 Plumb to Drain 10 Operation Start Up 11 Alarms 12 Maintenance Quarterly...

Страница 4: ...ns 17 Grains 17 Grains 17 Grains 17 Grains 17 Grains MAX TDS 2500 PPM 2500 PPM 2500 PPM 2500 PPM 2500 PPM 2500 PPM MAX IRON 0 1 MGL 0 1 MGL 0 1 MGL 0 1 MGL 0 1 MGL 0 1 MGL MAX PSIG 80 80 80 80 80 80 M...

Страница 5: ...8 Membrane Installation Membrane Brine Seal Note All Membrane Vessels are clearly marked with flow direction Membrane Brine Seal is always facing the water entry to Vessel Flow Direction Marking Membr...

Страница 6: ...ked with HOT and Cold connections RO FEED WATER MIN MAX PSIG PIPE SIZE FLOW RATE HS 450 25 80 psig 2 GPM HS 100 25 80 psig 4 GPM HS 2400 25 80 psig 8 GPM HS 4800 25 80 psig 1 12 GPM HS 9600 25 80 psig...

Страница 7: ...ule 40 PVC HS15 000 1 MPT x 1 Female slip schedule 40 80 PVC Ball Valve used with Pressure Tank applications Note Fittings are included with systems ordered as complete packages only Permeate Line Con...

Страница 8: ...ipe is UNSUITABLE for any plumbing from RO Storage Tank Recommended materials include Braided Stainless Steel Tubing Hard Stainless Schedule 80 PVC or Poly Propylene is acceptable if not being connect...

Страница 9: ...Stainless Schedule 80 PVC or Poly Propylene if not being connected to boiler or heating system HS 450 3 8 HS 1000 3 8 HS 2400 3 8 HS 4800 3 4 HS 9600 3 4 HS 15 000 1 Plumb Drain Connection located on...

Страница 10: ...ponding electrical connection on the atmospheric tank 2 Connect the gray electrical cable from Control Box labeled By Pass Solenoid to the By Pass Solenoid 3 Connect the gray electrical cable from Con...

Страница 11: ...itch 1 to ON position The Water inlet solenoid valve will open There will be a 5 second delay before the pump starts The system may cycle on and off automatically during initial start up as air is pur...

Страница 12: ...tically be in Auto Bypass until the tank has completely filled The Auto by pass will only be triggered if the tank pressure drops below 5 psi Pressure tank systems Float switch controlled Atmospheric...

Страница 13: ...o the OFF position 4 Close Ball Valve on Permeate Line Connection on Bulkhead Pressure Tank Systems 5 Unplug unit from Power Supply 6 Place bucket under pre filters to catch the water from the filter...

Страница 14: ...ventive maintenance Include replacement of O Rings Replace RO membrane by loosen retaining clamp at top of stainless steel membrane vessel Carefully pry loose PVC end cap from stainless steel vessel P...

Страница 15: ...d PVC Vessel Cap with K Y Jelly or other water soluble lubricant Vaseline or other petroleum based lubricants will damage rubber o ring and cause leaks Insert new membrane into vessel with the Brine S...

Страница 16: ...ater pressure exceeds 80 psi a pressure regulator must be installed 4 Incoming water temperature cannot exceed 100 F 40 C This warranty does not cover any equipment that has been relocated from the si...

Страница 17: ...to transport concentrated waste water to a suitable drain Feed pressure Referring to the water pressure being supplied to the RO processor before it has entered the pre filter Raw water Feed pressure...

Страница 18: ...mi permeable membrane This process is called reverse osmosis because the pressure forces the water to flow in the reveres direction from the concentrated solution to the dilute solution to the flow di...

Отзывы: