5
Maintenance
Removing Carbon Media
1. Turn off water at supply valve or at main valve to home.
2. Open faucet in home to relieve pressure from E-Treat system,
then place the system into the bypass position. Once placed
in the bypass position, the main water supply valve can be
turned to the ON position to restore water flow to the home.
3. Loosen nuts on bypass valve to E-Treat system as shown
in Diagram A.
4. Separate E-Treat system from bypass valve as shown in
Diagram B.
5. Unscrew head from tank counterclockwise as shown
in Diagram C.
6. Use a wet/dry vacuum to extract carbon from vessel.
7. Start the vacuum and slowly push the hose into carbon bed
as shown in Diagram D. Add water as needed until all carbon
is removed.
Diagram D
Diagram A
Diagram B
Diagram C
WARNING
!
To avoid risk of electric shock, use only a wet dry vacuum
rated for water applications. Must be used in conjunction
with a ground fault circuit interrupted (GFCI) power outlet.
Содержание E-Treat ETREATWCS
Страница 12: ......