Dimensions:  3-3/8" x 3-3/8"

The Watts Radiant DualTemp thermostat has the ability to sense 
the temperature of the air, fl oor or a combination of air and fl oor. 
Each DualTemp comes with an internal air sensor. An OPTIONAL 
external 10k sensor which allows detection of fl oor temperatures may 
be ordered separately. The external sensor does not have to be used if 
the DualTemp is to detect air temperatures only.

 

For  Residential and Commercial Applications

08-04

Job Name   ––––––––––––––––––––––––––––––––––––––––––– Contractor 

 

 ––––––––––––––––––––––––––––––––––––––––––––

Job Location   ––––––––––––––––––––––––––––––––––––––––– Approval 

 

 –––––––––––––––––––––––––––––––––––––––––––––

Engineer   ––––––––––––––––––––––––––––––––––––––––––––– 

Contractor’s P.O. No.   –––––––––––––––––––––––––––––––––––

Approval   ––––––––––––––––––––––––––––––––––––––––––––– Representative 

 

 ––––––––––––––––––––––––––––––––––––––––

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only.  For precise measurements, 
please contact Watts Technical Service.  Watts reserves the right to change or modify product design, construction, specifications, or materials 
without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

4      4      2       2      6      7

NTC     A/B

Wall Anchor Point

Power Connections

Electrical Access

Optional Sensor Connections

Optional Floor Sensor

Screw Cover

Cover Screw

+/- Adjustment and
Temperature Set Buttons

Mounting Screw

Base

Digital Display

Cover

DualTemp Digital Thermostat

DESCRIPTION PROPERTY

Operation Voltage 

24V 

 

Contact 

10A, 230Vac Relay

Sensor 

NTC 10K Thermistor

Static Differential 

1°F 

Proportional 

10 minutes for 3.5°F

Built-in manual setback 

7°F

Air Temp Range 

41- 99°F

Floor Temp Range 

41- 99°F

°C °F

10 50.0
15 59.0
20 68.0
25 77.0
30 86.0
35 95.0

Installation & Operation

To mount the thermostat remove the thermostat cover by removing the 
white Screw Cover (located in the center of the thermostat cover) and 
the Cover Screw. Secure the Base Unit to the wall. Be sure to feed the 
electrical wiring (18-3 or 18-4) through the provided slot in the Base Unit 
and connect to appropriate terminal block(s). Replace the Cover, Cover 
Screw and Screw Cover.

If fl oor sensing is desired, make sure the fl oor sensor is connected to 
the corresponding fl oor sensor terminals (labeled NTC, the fi rst two 
terminals on the right terminal block). It may be necessary to adjust the 
J6 setting. See wiring diagrams for details.

Changing Values

To enter the pa rameter menu, press and hold the 

OK

 button for 5 seconds. 

Use the +/- keys to select the installation parameter to be adjusted. Press 

OK

 to 

toggle the parameter setting or to edit its value. When the value begins to blink, 
use the +/- keys to adjust its value. Press OK to select the adjusted value. Use the 
+/- keys to select the next parameter and repeat.

Toggle to “End” and press OK to exit the installation parameter menu.

DualTemp Thermostat with opitonal fl oor sensor.

Product Options

Qty

Description

Model #

Order #

DualTemp, 24V Digital, Air/Floor

P-3285

81009395

Floor Sensor, 10K

500802

81000505