CONTROL SETTINGS AND PARAMETERS

J0:

 

°C/°F Temperature display section.

J1:

 

 Hot/Cold regulation mode. Select Hot for Heating, Cold for cooling.

 

 

Hot:

 opens actuator when temperature rises above setpoint.

 

 

Cold:

 closes actuator when temperature closes below setpoint.

Cy

:  

Proportional Integral regulation time cycle, value in minutes 
(default: 15 minute cycle).

 

 

 This setting adjusts how frequently the control monitors the sensor 
readings. Lower mass systems (frame fl oor aplications) can loose 
heat faster than high mass systems (slabs) and may require a faster 
cycle time.

bp:

   Proportional Integral regulation band amplitude value in degrees °C/°F 

(default: 2.0°C/3.6°F).

 

 

J4:

 

 NO/NC Normally Open or Normally Close actuator selection. 

 

 

NC: If using an isolation relay and/or a relay box.

 

 

NO: if connecting to a Watts Zone Valve control.

J5:

 

 Select PMP (Pump Maintenance Program) to perform a 1 minute 
exercise everyday.

 

 

 Use this setting to allow the thermostat to cylce the circulator for 
1 minute every day. This setting helps maintain lubircation during 
no-heat periods.

J6:

 

 Air:  

Air (room) setpoint. Displays air temperature with fl oor low (FL) and 
high (FH) limits.

 Flr: 

 

Floor (external sensor) setpoint. Displays fl oor temperature without 
fl oor low/high limits. Air temperature is not a control boundary.

J7:

 

 rEG (proportional Integral) or HYs (0.3°C Hysteresis) regulation 
type selection.

 

 

rEG

 is prefered setting for use with radiant applications.

 

 

HYs

 is prefered setting for use with forced air or other 

 

 

    covection systems.

Cp:

   Proportional Integral regulation temperature compensation value in °C/°F 

(default: 2.0°C/3.6°F).

 

 

 Adjusts the calibration between the displayed temperature reading 
and the calibrated temperature reading. Do not adjust this value 
unless necessary.

Ao:

   Air Sensor offset adjustment (default: no offset), display measure air sensor 

value.

 

 

 Adjust the display reading to match the air sensor reading. 

Fo:

   Floor sensor offset adjustment (default: no offset), display measure fl oor 

sensor value.

 

 

 Adjust the display reading to match the fl oor sensor reading. 

FL:

   Floor temperature LOW limitation (default: 5°C/41°F), effective only if fl oor 

sensor present and set 

J6

 to 

Air

.

 

 

 This setting keeps the fl oor from dropping below the 
designated temperature.

FH:

   Floor temperature HIGH limitation (default: 28°C/82°F), effective only if fl oor 

sensor present and set 

J6

 to 

Air

.

 

 

 This setting keeps the fl oor from rising above the 
designated temperature.

CLr:

 Press 

OK

 to reset to factory defaults.

End:

 Press 

OK

 to exit installation parameters.

Com fort Operating Mode (Sun):

 Press +/- button(s) to adjust the 

desired setpoint.

Nigh t Setback Mode (Moon):

 Sets the operating temperature to a lower point. 

Use the +/- button(s) to adjust the setback temperature.

Time r  (Clock): 

Thermostat can be tied into an external timer to control system 

operation.

 

 

Blinking sun indicates system is in Comfort Mode.

 

 

Blinking moon indicated system is in Setback Mode.

Optional
Floor
Sensor

Digital DualTemp with Transformer and Relay

Transformer

Black

Green

White

Green

White

Black

Fusetron

2

4

Vac

 Hot

Neutr

al

To Relay Coil "A" Side

To Relay Coil "

B

" Side

4      4      2       2      6      7

NTC     A/B

Requires jumper between 2 & 6

Optional
Floor
Sensor

Digital DualTemp with Third Party Relay Box

To "T1" Terminal

 1   2   3

4

Transformer

24VAC

X

X

ZONE 3

ZONE 1ZONE 2

ZONE

4

POWER

INPUT

ZONE 2

ZR

ZC

ZONE 1

ZONE 3 ZONE

4

To "T2" Terminal

4      4      2       2      6      7

NTC     A/B

R

C

J1

°F
°C

Operating Mode Menu 
(power, comfort, set-back, timer)

Heat/Cool Operation Indicator

Indicates Display is Showing 
Current Temperature

Shows Measured or Set Temperature

Operation Parameter (see chart for details)

Note:  Do not apply power to the relay ("dry" contact) terminals on the 

DualTemp. Doing so will cause damage to the thermostat.

Do not apply line voltage (120 volt) power to thermostat. Applying anything other 
than the recommended 24 volt power will damamge the thermostat. 

   