3
1 INSTALL YOUR CENTRAL
a- Wall
mounting
.
1- Connect the power as described below :
2- Screw the power unit on the wall
and connect to power
supply. Note!
The tab must be on the top!
3- Put the switch on ON position
4- Mount the Central
control
on the power unit and slide it on
the bottom to clip it. The Central is ready for operation.
b-
Table installation
(with optional mini USB
cable – sold seperately)
Connect the central unit with the
mini USB
cable (5V, 1A) and
then mount the leg support on it and put the switch on ON
position. The central unit is ready for operation.
MAIN SCREEN
ICONS
Date
Display the time or the ambient T° of the room or zone. Make
your choice by pressing on the central part of the screen
Outside sensor temperature
Screen lock. Long press toggles between locking / unlocking.
Error flag – press to access RF, limits, alarms, battery
anomalies.
The device is working on battery (! only for settings and pairing).
Rooms access (if Central is locked - cannot change settings).
Main menu.
Holidays mode status.
Boiler status displayed if connected to the Central.
Display the ambient temperature in one room
GENERAL PICTOGRAMS
To return to the main screen.
To return to the previous screen.
The buttons with a red point need a
long press (min 5s).
2 ADJUST TIME / USER SETTINGS
Set the time and the date manualy
or automatically. If you
select auto, you have to set the time zone (UTC) and the device
is getting the time from internet (WIFI connection is mandatory).
Set your language - see MAIN MENU section
Personalise your screen settings, eg background colour etc
See “User Settings Menu” in MAIN MENU section (page 8) for
further information.