17
IOM-WQ-BB-S100
2127
EDP# 68110146
© 2021 Watts
Performance Data Sheet
Certified Substance Reduction
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:
Depending on incoming feed water conditions, replacement gallon capacity
may vary.
Description
Big Bubba BB-S100 Complete Whole Home Solution for the Reduction of
Lead, PFAS, Cyst, and Chlorine Taste & Odor
System Model/Part Number
BB-S100 / 7100976
Capacity
84,480 Gallons / 319,791 Liters
Replacement Filter Cartridge
Carbon Block Filter Cartridge for the Reduction of Lead, PFAS, Cyst, and
Chlorine Taste & Odor Model Number BB-C100 / Part Number 7100980
Minimum/Maximum Operating Water Temperature
34 to 125°F / 1 to 52°C (125°F / 52°C at 80psi maximum pressure)
Minimum/Maximum Water Pressure
25psi to 125psi /1.75 Kg/cm2 to 8.78 Kg/cm2
Rated Service Flow
4 GPM (15 LPM)
Pressure Drop of System at Rated Service Flow
10psig
SUBSTANCE
AVERAGE INFLUENT
NSF/ANSI INFLUENT
CHALLENGE CONCENTRATION
PERCENT REDUCTION
REQUIREMENT/MAXIMUM
PERMISSIBLE PRODUCT
WATER CONCENTRATION
AVERAGE % REDUCTION @
FLOW RATE GPM (LPM)
PEAK FLOW &
% REDUCTION
OF LEAD
NSF/ANSI 42 — Aesthetic Effects
Chlorine
2.0 mg/L
2.0 mg/L ± 10%
≥ 50%
97.90% @4 GPM (15 lpm)
7 GPM (26.4 lpm) @
99.62% reduction
(*) >74,000 gallons
at 8 GPM (280,090
Liters @ 26.4 lpm)
NSF/ANSI 53 — Health Effects
Cyst
126,000/L
Minimum 50,000/L
> 99.95%
99.97% @4 GPM (15 lpm)
Lead pH 6.5
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.005 mg/L
99.62% @4 GPM (15 lpm)
Lead pH 8.5
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.005 mg/L
99.62%@4 GPM (15 lpm)
PFAS
.0015 mg/L ±10%
.0015 mg/L ± 10%
0.00007 mg/L
98.26% @4 GPM (15 lpm)
Not all water will contain contaminants listed. Testing performed under standard laboratory conditions; actual performance may vary. Filter system usage must comply with all state and
local laws. Filter system is only to be used with cold water. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. Flush new filter cartridge for 10 minutes to prepare it for use. Spent
adsorption media shall not be regenerated and used.
SUBSTANCE
AVERAGE INFLUENT
CONCENTRATION
INTERMITTENT PEAK FEED FLOW
RATE GPM (LPM)
ESTIMATED GALLON CAPACITY @
INTERMITTENT PEAK FEED FLOW
RATE
ESTIMATED NEW CARTRIDGE
PERCENT REDUCTION OF
SUBSTANCE @ INTERMITTENT
PEAK FLOW RATE
Chlorine
2.0 mg/L Free Chloine
13 GPM (49.2 lpm)
264,000 Gallons (999,348 liters)
90%
Chloramine
3.0 mg/L Free Chloramine
7 GPM (26.4 lpm)
132,000 Gallons (499,674 liters)
85%
*Claims are not performance tested or certified by IAPMO. Performance claims are based on independent laboratory and manufacturer’s internal test data.
Actual performance is dependent on influent water quality, flow rates, system design and application. Results may vary.
Non-Certified Substance Reduction*
BB-S100 system has been certified by IAPMO R&T against NSF/
ANSI 42 and 53 for the reduction of substances listed below. The
concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/
ANSI 42 and 53. The system is certified to CSA B483.1 and NSF/
ANSI 372 for Lead Free compliance.
Treated water from system should be tested at regular intervals to
ensure quality and safety at point of use.
Contact:
USA
Watts
815 Chestnut Street
North Andover, MA 01845-6098
Phone: 978-689-6066
Fax: 978-975-8350
Watts.com
Canada
Watts
5435 North Service Road
Burlington, ON L7L 5H7
Phone: 888-208-8927
Fax: 905-481-2316
Watts.ca
Refer to Owner’s Manual and Installation instructions for installation, operation, maintenance, and warranty information.
For Purchases Made In Iowa
Buyers Name: _______________________________________
Date: ______________________________________________
Sellers Name: _______________________________________
Date ______________________________________________
The seller shall retain the signed PDS on file at the seller's place of
business for at least two years.