Modulex EXT Commercial Series
CHAPTER 4: Installation Instructions
OMM-0160_A
• DRAFT Technical Support • (800) 526-0288 • Mon-Fri, 8 am - 5 pm EST Page
37
of
117
Figure 4-10: Connection of Exhaust Manifold to Boiler Flue Exhaust Outlet
For venting systems in the USA, it is necessary to assemble the Euro-to-USA adaptor to the flue
manifold as shown in Figure 4-11.
Figure 4-11: Assembly of European-to-American Flue Adaptor to Flue Manifold
NOTE:
The gasket may seem large. It is intentionally designed to produce a tight fit.
European-To-American
Flue Adapter
FLUE MANIFOLD
Gasket For Attaching
European-To-American Flue Adapter
Flue Manifold
Nuts (10)
Washers (10)
RECTANGULAR GASKET
Gasket For Attaching European-to-
American Flue Adapter