background image

Place a towel under the filter module to catch any excess water that 

may drip out from the filters during the changeover.

Step 1     

Your  system  is  equipped  with  valved  heads  which  will  automatically  turn  off  the 

water supply to each filter when the filter is released, thus you do not need to turn 

off the incoming water supply at the Adapt-a-Valve. The faucet must be off when 

filters are replaced. To make the removal of the filter cartridges easier, the heads 

&  cartridges  may  be  swiveled  up  to  90  degrees  as  shown  in  the  pictures  below.

Step 2    

To  install  a  filter  cartridge:

  Remove  the  seal  cap  and  insert 

the cartridge into the valved head until you hear an audible “click” 

(the  button  does  not  need  to  be  pressed  to  install  new  filters).    

Step 3   

To remove a filter cartridge:

 Push & hold the button on the 

valved head above the filter. Pull cartridge downward (from the 

head) to remove. Release button and discard old filter.  

Changing The Filter Cartridges

√ 

One sediment filter  

(Red Label P/N: 105311)

√ 

One LVOC Block   

(Blue Label P/N: 105371)

Replace:

6 Month System Maintenance

√ 

Granular Activated Carbon  

(P/N: 105341)

Optional Filters:

9

√ 

One sediment filter  

(Red Label P/N: 105311)

√ 

One LVOC Block   

(Blue Label P/N: 105371)

√ 

One UF Membrane  

(Purple Label P/N: 105321)

Annual System Maintenance

Replace:

Note: 

If the new filter cartridge won’t snap in easily or pops off it may be 

due to high incoming water pressure. Relieve pressure to the system by 

turning off the water supply using the adapt-a-valve and then install the 

cartridge. Once the cartridge is seated, turn the water supply back on to 

your unit.

Содержание Filter-Pure UF3

Страница 1: ...e read carefully before proceeding with installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure Refer to enclosed warranty for operating...

Страница 2: ...which uses standard home water pressure to push water through its semi permeable membrane Suspended particles and materials of high molecular weight are unable to pass through the 0 02 micron UF memb...

Страница 3: ...nder Sink System Start Up Changing The Filter Cartridges Performance Data Sheet Other Products from Watts Premier Warranty Registration Removing Chlorine From Your Shower Warranty 3 4 4 4 4 5 6 6 7 7...

Страница 4: ...rs If any of the items are missing please contact Watts Premier prior to installing Operating Temperatures Maximum 100 F 37 8 C Minimum 40 F 4 4 C Operating Pressure Maximum 85 psi 6 0 kg cm2 Minimum...

Страница 5: ...liquid soap to keep the hole saw cool during cutting Step 2 Drill a Hole for the Faucet in a Porcelain Sink Punch a Hole for the Faucet in a Stainless Steel Sink Drill a pilot hole Use a 1 2 Hole Pun...

Страница 6: ...er Configuration for 3 8 compression fittings Configuration for 1 2 compression fittings Hot Supply Cold Supply Caution Water supply line to the system must be from the cold water supply line only Hot...

Страница 7: ...and or before use To disconnect ensure the system is depressurized before removing the tube Push in collect squarely against face of fitting With the collet held in this position the tube can be remo...

Страница 8: ...to flush out the normal black carbon fines it will sputter until the air is purged out from the unit Initially the water may appear cloudy which is due to tiny air bubbles and it will clear up shortl...

Страница 9: ...not need to be pressed to install new filters Step 3 To remove a filter cartridge Push hold the button on the valved head above the filter Pull cartridge downward from the head to remove Release butt...

Страница 10: ...0 0 015 DIBROMOCHLOROPROPANE DBCP 99 0 052 0 00002 o DICHLOROBENZENE 1 2 Dichlorobenzene 99 0 08 0 001 p DICHLOROBENZENE para Dichlorobenzene 98 0 04 0 001 1 2 DICHLOROETHANE 1 2 DCA 95 0 088 0 0048 1...

Страница 11: ...99 0 081 0 001 PENTACHLOROPHENOL 99 0 096 0 001 PERCHLOROBUTADIENE see HEXACHLOROBUTADIENE 98 0 044 0 001 PROPYLENE DICHLORIDE see 1 2 DICHLOROPROPANE 99 0 080 0 001 SIMAZINE 97 0 120 0 004 SILVEX se...

Страница 12: ...ll water supply or areas where dirt and rust particles are a problem Includes three 50 micron sediment filters and wrench 3 4 ports Part No 500223 Replacement filter Part No 304007 PoolDocTM accuratel...

Страница 13: ...ration information for you XXXXX XXXXXX Watts Premier Inc is concerned for the safety of your personal information Watts Premier collects personal information when you register with Watts Premier This...

Страница 14: ...USA CANADA MEXICO OTHER ____________ Phone ______ __________ __________ Email Address ______________________ Date of Purchase ___________________ Date of Install _______________________ Installed By...

Страница 15: ...t Swivel Ball Extension Triple Plated Finish Reversible Filter Cartridge Model HHC Cartridge Life Rating 3 months Part No 107095 CHROME All In One reversible High Flow Filter Replacement filter Deluxe...

Страница 16: ...Counter Top cannot exceed 100 degrees F 38 degrees C This warranty does not cover any equipment that is relocated from the site of its original installation This warranty doe not cover any charges in...

Отзывы: