18
18 

Battery Torque Wrench 

User Manual 

 

 

 

cancel the torque cycle. 

 

3) when "ready" is displayed on the screen, the tool is ready for the next torque. 

 

4)  when  tightening,  it  shall  be  ensured  that  there  is  a  tightening  angle  of  more  than 

 

180 degrees. It is not allowed to directly continue tightening after tightening. 

 

 
 

5.3.8 Safety device (switch lock)

 

 

 

The switch lock is used to move the tool from one direction to another. Starting it is to 
prevent  the  switch  on  the  electric  torque  wrench  from  being  pushed.  If  you  want  to 
start the switch lock, simply move the switch on the handle of the electric torque wrench 
to the middle. 

 

 

5.4 Brush replacement

 

 

 

When the motor is overheated, the equipment  shall  be shut  down for  a  period of 

time to avoid excessive loss of brush caused by overheat. 

 

 

After  half  a  year  of  use  or  frequent  use,  check  the  motor  brush  every  month. 

Otherwise, if the motor brush is used after the loss, it will cause damage to the motor 

or other adverse conditions.

Содержание ATM Series

Страница 1: ...AL Perth Branch 9 Venture Loop Wangara WA 6065 P 08 9302 4103 E enquiries watorquetools com au Karratha Branch U 8 9 985 Woodbrook Rd Karratha WA 6714 P 08 9185 2008 E wattsales watorquetools com au www wattwa com au ...

Страница 2: ...hapter 4 Function Description 5 4 1 Work Interface 5 4 2 Main Menu Mode Setting 6 4 3 Main Menu Preset Value 7 4 4 Main Menu Unit Settings 8 4 5 Main Menu Machine Data 8 4 6 Main Menu Language 9 4 7 Main Menu Exit 9 4 8 Main Menu Calibration 10 Chapter 5 General Operating Instructions 12 5 1 General Safety Rules 12 5 1 2 Electrical Safety 13 5 1 3 Personal Safety 13 5 1 4 Power Tool Use and Care 1...

Страница 3: ...Ion Battery Pack 15 5 3 3 Checking Battery Charge 15 5 3 4 Charging the Li Ion Battery Pack 16 5 3 5 Setting direction of rotation 16 5 3 6 Installing the Reaction Arm 17 5 3 8 Safety device switch lock 18 5 4 Brush replacement 18 Chapter 6 Tool Warranty 19 New tool warranty 19 Paid maintenance and warranty 19 Items not covered by warranty 19 ...

Страница 4: ...perating specifications are in Section 1 of this manual The installation connection and use require skilled operation Dis assembly or repair must not be attempted If the equipment fails to operate correctly contact the distributor or manufacturer for instructions WARNING Do not operate the tool in explosive atmospheres such as in the presence of flammable liquids gases or dust The tool creates spa...

Страница 5: ...cts If the battery terminals are connected by a metal object the battery will short and will cause damage to the battery and injury to the operator WARNING Do not expose the Li Ion Battery Pack to wet conditions This will cause damage to the Battery and increase the risk of electric shock Do not use faulty or deformed Batteries Do not attempt to open the Battery Do not short circuit the Battery Fa...

Страница 6: ... of any power tool is to a great degree dependent on yourself as the user Please take account of the information contained in these operating instructions and the accompanying documents The more care you exercise in handling your Digital Battery Torque power tool the longer it will provide reliable service to you Specifications 2 1 Specifications Battery Output Units Model Voltage 18 VDC V 18 Curr...

Страница 7: ... Handle introduction The handle of the digital charging torque wrench is composed of a direction forward rotation reverse rotation controller and a start stop trigger The battery slides into the bottom of the handle and connects to provide power and display Monitor Air cooled high capacity lithium battery High precision planetary gear can be equipped with high speed system Antiskid rubber sleeve S...

Страница 8: ...r 4 times and when it has exceeded the maximum current it should be shut down immediately when the buzzer continuously rings for 3 times it means that the current torque has exceeded the preset value and it should be shut down immediately when the buzzer keeps ringing the screen will display the low power reminder and the rotation speed of the torque wrench will be significantly reduced which mean...

Страница 9: ...r the bolt is loosened Note do not use this equipment to loosen the bolts beyond the torque range of this equipment Before use please confirm whether the direction of the forward and reverse switches is the direction of use Do not press the trigger again after tightening the bolts Use this tool to tighten or loosen the bolts at the correct torque 4 2 Main Menu Mode Setting Note in the working inte...

Страница 10: ...disassembly value Maximum value of default torque not editable Preset value01 10 Press the key or key to move to the corresponding 10 preset values and press the key to enter the editing operation Select edit or application by pressing key or key and confirm to select corresponding function by pressing key Edit The preset value can be input and set The default value is 4 digits If it is less than ...

Страница 11: ...vious input and input as the decimal point Preset value Sign out Press the key to return to the main menu 4 4 Main Menu Unit Settings Under the main menu press or to select the unit setting and press to enter the unit setting menu Only in mode 1 can the unit be selected Press or to select the required unit press to confirm the selection of the corresponding unit and return to the main menu 4 5 Mai...

Страница 12: ... the main menu press the key or key to select the Chinese English switch and press the key to enter the Chinese English switch menu You can select the system language Chinese or English by pressing the key or key Press the key to confirm the selection and return to the main menu 4 7 Main Menu Exit Under the main menu press or to exit press to enter and confirm to return to ...

Страница 13: ...e attached list for the password or ask the company s engineer Use the and keys to move the brackets and use the key to select the number In the calibration menu press or to select six point calibration and press to enter the six point calibration menu calibration Six point calibration In the six point calibration menu press the key or key to select the six point recalibration and span value setti...

Страница 14: ... is tightened click the key to input the torque value on the tester and then loosen the tester Move the interface to the right and enter the update interface after cycling 6 values Click to update 4 interfaces need to be updated Click to set span value key click to reset the power value of low power prompt The user does not need to enter the interface ...

Страница 15: ...n short intervals This allows cooling between use and will prevent the case from becoming to hot to handle 5 1 General Safety Rules WARNING Read all instructions Failure to follow all instructions listed below may result in electric shock fire and or serious injury The term power tool in all of the warnings listed below refers to your mains operated corded power tool or battery operated cordless p...

Страница 16: ...oes hard hat or hearing protection used for appropriate conditions will reduce personal injuries 5 1 4 Power Tool Use and Care 1 Do not force the power tool Use the correct power tool for your application 2 Do not use the power tool if the switch does not turn it on and off Any power tool that cannot be controlled with the switch is dangerous and must be repaired 3 Disconnect the plug from the pow...

Страница 17: ...ear of the reaction arm and the contact point 5 NEVER exceed the maximum tool rated torque Failure to do this will void warranty 6 Making sure the reaction arm snap ring is securely in place to hold the reaction arm or blank in place 7 ALWAYS support the tool in use The tool must be supported at all times in order to prevent unexpected release in the event of fastener or component failure 8 Ensure...

Страница 18: ... Battery 1 Ensure the On Off Trigger is in the Off Position not depressed 2 Align the Battery with the bottom of the Tool Handle 3 Slide the Battery into place until it is full seated Note A click will confirm that the Battery is locked in place 4 Test that the Battery is locked in place by trying to slide it out of place To remove the Battery 1 Press and hold the Battery Release Button 2 Slide th...

Страница 19: ... capacity To remove the Battery Green Status Light Red Warning Light Charge Button 1 Slide the Battery away from the Charger 2 Check that the Battery is fully charged Charging Errors The Red Warning Light is on The Battery is not charging because its temperature is not within the required range for charging When the Battery s temperature moves within the required range the Red Warning Light will t...

Страница 20: ...ke sure the reaction arm is in contact with a solid contact point before you operate the tool WARNING Keep your body parts clear of the reaction arm when the tool is in operation 5 3 7 Torque Operation This section explains how to properly torque a bolt using the Digital Battery Torque Torque Tool This operation can be used in tool locked or unlocked mode WARNING The Digital Battery Torque should ...

Страница 21: ... from one direction to another Starting it is to prevent the switch on the electric torque wrench from being pushed If you want to start the switch lock simply move the switch on the handle of the electric torque wrench to the middle 5 4 Brush replacement When the motor is overheated the equipment shall be shut down for a period of time to avoid excessive loss of brush caused by overheat After hal...

Страница 22: ...e problems occurred and the exact time You need to pay the freight to send the damaged parts to the company When repairing the tool the supporting action arm shall also be sent back together Items not covered by warranty In the judgment of the company the replacement damage incorrect use of tools or parts caused by excessive use loss or incorrect storage or the failure caused by non product reason...