Instance
11
Warning
number
Attribute ID
Description
Type
Value
1 Name
Byte-String
“Warning
number”
2 Data-type -
Integer
3 Elements -
1
4 Access -
Read
Only
5 Data
value
Integer
Warning number
6
6 N.A.
Integer
7 N.A.
Integer
Read
8 N.A.
Integer
Instance
12
Firmware
Version
Attribute ID
Description
Type
Value
1 Name
Byte-String
“Firmware
Version”
2 Data-type -
Integer
3 Elements -
1
4 Access -
Read
Only
5
Data value
Integer
MC100 Firmware version
6
Data value
Integer
MC100 Firmware build no.
7
Data value
Integer
Pump HW and SW
Read
8 N.A.
Integer
The data value for attribute 5 is 4 BCD digits
3 (MSB)
2
1
0 (LSB)
Version(x10) Version(x1)
Major
Minor
Example Version 1, revision 3.7
0 1 3 7
The data value for attribute 6 is build number [integer]
The data value for attribute 7 is 2 bytes
3 (MSB)
2
1
0 (LSB)
TBD
TBD
Pump software
Pump hardware
Pump hardware: BCD1, BCD0.
Pump software: Version = byte/10.
6