8 Alarm and warnings
8.1 Alarms handling
When MC100 is in Alarm state, the only possible action is to reset the alarm. Only applies if the alarm
causes are removed, otherwise the alarm will re-appear at the next attempt.
Alarms are cleared one-by-one, starting top down – meaning lowest number first.
8.1.1 Alarms
Alarm no.
Alarm description
Action
0
No pending alarms
1
No pumps connected during
power up
Check connections /power to pumps
2
Connection to one or more
pumps lost
Check connections /power to missing pump
3
Connected pumps not equal to
last time
Configuration changed – Investigation or new
initialization must be done
4
Attempt to access not
connected pump
5
Reverse direction not available
Pump command Bit 5: Direction
set for one direction pump
6
Unstable FlexNet: Check
pumps
7
7
FRAM storage failure: Restart
or Reset
8
Mode change not completed:
check pumps
Changing mode was not possible, check pump
versions, if change was to parallel or serial mode
9
Missing or defect Anybus
CompactCom Module
No Alarm string available, because module not working
10 Disable/Enable
fail
Attempt to Disable or Re-enable pumps has failed in
the current mode.
11 Reserved
12 Reserved
13 Reserved
14 Reserved
15 Reserved
16 Reserved
17 Reserved
NN
FB module not Ready
8
Internal MC100 module check, possible replacement of
module.
7
Expected to be implemented in a later version
8
Alarm is only displayed with the 2 LED’s on MFSC module – both flashes RED.