13.7
SCADA N-Module
Note: Not all functions may be available, those available will depend on your pump model.
J1
J12
J13
J14
J15
2
1
J2
J3
J4
J5
J6
J7
J10
SW1
SW2
J11
J8
J9
N/O
N/C
C
N/O
N/C
C
N/O
N/C
C
N/O
N/C
C
V
mA 0V
B
0V
A
2
1
2
1
2
1
2
1
+10V
0V
i/p
0V
+12V
i/p
0V
RS485
Tube monitor Analog 2 Rem pot
Direction
enable link Analog 1 Run/stop i/p
Dose i/p
Direction i/p
Auto/man i/p
Tacho o/p
Relay 4
Relay 3
Relay 2
Relay 1
Recommended control cable: metric = 0.14sq mm - 2.5sq mm solid and 0.14sq mm - 1.5sq mm
stranded. USA = 26AWG - 14AWG solid and 26AWG - 16AWG stranded. Cable: circular. Max/min outside
diameter to ensure a seal when passed through the standard gland: 9.5mm-5mm.
The cable section
must be circular to ensure a seal.
Never apply mains power above 130V AC to the terminals within the SCADA
module. Apply the correct signals to the terminals shown. Limit signals to the
maximum values shown. Do not apply voltage across other terminals.
Permanent damage, not covered by warranty, may result.
•
130VAC Max on Relay 1-4 terminals, Dose, Auto and Start Stop
•
All others Max 30VDC
The maximum rating on the relay contacts of this pump is 1250VA.
36
m-730un-en-08.1