Pumphead type
Value
Pumphead
0x—80
720R
0x—81
720RE (Sanitary element)
0x—82
720RE (Industrial element)
Note:
Numerical values cannot include a decimal point. To enter a speed, move the decimal point one
place to the right and enter an integer. To enter a tube size, move the decimal point two places to the
right and enter an integer. See examples below:
Speed (rpm)
Value
123.4
1234
Data examples
Set min/max speeds
The min/max speed parameters are used to set the minimum and maximum speed from the PROFIBUS
interface. The values are only used if the matching bit in the Control Word is enabled and they are not
zero. All values are 16 bit unsigned in 1/10th of RPM of the head speed.
Fail-safe
The fail-safe user parameter is used to set the correct course of action to take in the event of a PROFIBUS
communications failure. The fail-safe byte is configured as shown in the following table. If no bits are set
or an invalid bit pattern is set the default fail safe behaviour shall be to stop the pump.
Bit
Description
0x00
No fail safe action
0x01
Last demanded speed
0x02
Fail-safe speed
The fail-safe speed parameter is used to set the speed at which the pump should be driven is a PROFIBUS
communications error occurs and if bit 1 in the fail safe user parameter is set.
PROFIBUS data exchange
Default address:
126
m-730un-en-08.1