Table 14 - Errors and warnings
ADI
Name
Access
Type
Description
102
Error bit field
Read
Uint32
Bit 0
Lead detected, Leak detect signal
high requires clearing and
acknowledging before pump can
resume.
Bit 1
Motor Stall error active If Set the
pump has a Motor Stall Error.
Please follow onscreen instructions
Bit 2
Motor Speed error, If set pump has
a speed error. Please follow
onscreen instructions
Bit 3
Over Current error active, If set the
pump has an over current error.
Please follow onscreen instructions
Bit 4
Over voltage error active, If set the
set the pump has an over voltage
error. Please follow onscreen
instructions
Bit 5
Guard open, If set then the guard
has been opened. Please follow
onscreen instructions to clear.
Bit 6
Flow sensor error active, if set flow
sensor error is active
Bit 7
Pressure sensor error active, if set
flow sensor error is active
m-530pn-en-09 02-02-22
89
Содержание 530 Pn
Страница 33: ...12 7 Network topology Figure 17 Star network m 530pn en 09 02 02 22 33...
Страница 34: ...Figure 18 Ring network Figure 19 Line topology 34 m 530pn en 09 02 02 22...
Страница 69: ...3 Press HOME to return and store the setting The input is now disabled in Manual mode m 530pn en 09 02 02 22 69...
Страница 71: ...3 Press HOME to return and store the setting The input is now enabled in Manual mode m 530pn en 09 02 02 22 71...
Страница 72: ...15 6 Help Help 1 Select Help from the main menu to access the help screens 72 m 530pn en 09 02 02 22...
Страница 81: ...1 Press the MODE key to access the MODE menu 2 Use the keys to select PROFINET m 530pn en 09 02 02 22 81...
Страница 84: ...4 Press BACK to return to the MODE MENU 84 m 530pn en 09 02 02 22...
Страница 129: ...Procedure 1 From the GENERIC SENSOR VALUES screen 2 Using the keys scroll to Set slope adjust m 530pn en 09 02 02 22 129...