13.2
First-time start-up defaults
If the Auto Restart feature is enabled it may cause the pump to start as soon
as power is turned on.
Auto Restart only affects operation of Manual mode and PROFINET® mode.
If Auto Restart is enabled the "!" Symbol is shown on the screen to warn users
that the pump may operate without any manual intervention (pump resumes
with previous settings).
Do not use Auto Restart for more than:
•
1 mains power start per 3 minutes
We recommend remote control where a high number of starts is required.
If the pump is configured to Dispense or PROFINET® mode it will respond to
remote commands at any time including immediately after power on. The
pump may operate without any manual intervention (e.g. a remote setpoint
could start the pump with no key press required).
The pump is preset with operational parameters as shown in table below.
Table 8 - First-time start-up defaults
Parameter
530 default
Language
Not set
Default mode
Manual
Default manual speed
220 rpm
Pump status
Stopped
Max speed
220 rpm
Direction
CW
Pumphead
520R2
Tube size
9.6 mm
Tube material
Bioprene
Flow calibration
15.12 ml/rev
Flow units
rpm
Pump label
WATSON-MARLOW
Asset number
NONE
SG value
1
Keypad lock
Disabled
PIN protection
Not set
Keypad beep
ON
38
m-530pn-en-09 02-02-22
Содержание 530 Pn
Страница 33: ...12 7 Network topology Figure 17 Star network m 530pn en 09 02 02 22 33...
Страница 34: ...Figure 18 Ring network Figure 19 Line topology 34 m 530pn en 09 02 02 22...
Страница 69: ...3 Press HOME to return and store the setting The input is now disabled in Manual mode m 530pn en 09 02 02 22 69...
Страница 71: ...3 Press HOME to return and store the setting The input is now enabled in Manual mode m 530pn en 09 02 02 22 71...
Страница 72: ...15 6 Help Help 1 Select Help from the main menu to access the help screens 72 m 530pn en 09 02 02 22...
Страница 81: ...1 Press the MODE key to access the MODE menu 2 Use the keys to select PROFINET m 530pn en 09 02 02 22 81...
Страница 84: ...4 Press BACK to return to the MODE MENU 84 m 530pn en 09 02 02 22...
Страница 129: ...Procedure 1 From the GENERIC SENSOR VALUES screen 2 Using the keys scroll to Set slope adjust m 530pn en 09 02 02 22 129...