A . 1 6
■
A p p e n d i x
Wa t l o w P o w e r S e r i e s
Display Loop
(See the Power Series User’s Manual)
Setup Page
[algo]
Control Algorithm
[ALgo]
Power Control Algo Select _ _ _
[`FTB]
Fixed Time Base _ _ _ _ _ _ _ _
[``UC]
Line Voltage Comp _ _ _ _ _ _ _
[Ctr1]
Control Zone 1
[``In]
Input Signal Method Select _ _ _
[dFlt]
Default Numeric Input Sig _ _ _
[nna_]
Set Analog Input Lo Cur _ _ _ _ _
[nna–]
Set Analog Input Hi Cur _ _ _ _ _
[Uol_]
Set Analog Input Lo Volt _ _ _ _
[Uo
l–]
Set Analog Input Hi Volt _ _ _ _ _
[lrn|a]
Learn Input Learn Req _ _ _ _ _ _
[bl`U]
Baseline Volt Read/Adj _ _ _ _ _ _
[lrn|U
]
Baseline Volt Learn Req _ _ _ _ _
[type]
Load Type Select _ _ _ _ _ _ _ _ _
[rATE]
Max Rate of Change _ _ _ _ _ _ _
[Soft]
Soft Start Time _ _ _ _ _ _ _ _ _ _
[Opt1]
Options Zone 1
[`Hbo]
Heater Bakeout Select _ _ _ _ _ _
[Min]
HBO Select Time _ _ _ _ _ _ _ _ _
[`HbC]
HBO Current Trip _ _ _ _ _ _ _ _
[`CLi]
Cur Limit Select _ _ _ _ _ _ _ _ _ _
[CL`A]
Cur Limit Set Point _ _ _ _ _ _ _ _
[tol_]
Lo Tol Set Point _ _ _ _ _ _ _ _ _ _
[tol–]
Hi Tol Set Point _ _ _ _ _ _ _ _ _ _
[Indf]
Induct Load Factor Req _ _ _ _ _
[ICur]
Inductive Current _ _ _ _ _ _ _ _ _
[Ctr2]
Control Zone 2
[``In]
Input Signal Method Select _ _ _
[dFlt]
Default Numeric Input Sig _ _ _ _
[nna_]
Set Analog Input Lo Cur _ _ _ _ _
[nna–]
Set Analog Input Hi Cur _ _ _ _ _
[Uol_]
Set Analog Input Lo Volt _ _ _ _
[Uo
l–]
Set Analog Input Hi Volt _ _ _ _ _
[lrn|a]
Learn Input Learn Req _ _ _ _ _ _
[bl`U]
Baseline Volt Read/Adj _ _ _ _ _ _
[lrn|U
]
Baseline Volt Learn Req _ _ _ _ _
[rATE]
Max Rate of Change _ _ _ _ _ _ _
[Soft]
Soft Start Time _ _ _ _ _ _ _ _ _ _
[Opt2]
Options Zone 2
[`Hbo]
Heater Bakeout Select _ _ _ _ _ _
[Min]
HBO Select Time _ _ _ _ _ _ _ _ _
[`HbC]
HBO Current Trip _ _ _ _ _ _ _ _
[`CLi]
Cur Limit Select _ _ _ _ _ _ _ _ _ _
[CL`A]
Cur Limit Set Point _ _ _ _ _ _ _ _
[tol_]
Lo Tol Set Point _ _ _ _ _ _ _ _ _ _
[tol–]
Hi Tol Set Point _ _ _ _ _ _ _ _ _ _
[Indf]
Induct Load Factor Req _ _ _ _ _ _
[ICur]
Inductive Current _ _ _ _ _ _ _ _ _
[Ctr3]
Control Zone 3
[``In]
Input Signal Method Select _ _ _ _
[dFlt]
Default Numeric Input Sig _ _ _ _ _
[nna_]
Set Analog Input Lo Cur _ _ _ _ _ _
[nna–]
Set Analog Input Hi Cur _ _ _ _ _ _ _
[Uol_]
Set Analog Input Lo Volt _ _ _ _ _ _
[Uo
l–]
Set Analog Input Hi Volt _ _ _ _ _ _ _
[lrn|a]
Learn Input Learn Req _ _ _ _ _ _ _ _
[bl`U]
Baseline Volt Read/Adj _ _ _ _ _ _ _
[lrn|U
]
Baseline Volt Learn Req _ _ _ _ _ _ _
[rATE]
Max Rate of Change _ _ _ _ _ _ _ _ _
[Soft]
Soft Start Time _ _ _ _ _ _ _ _ _ _ _ _
[Opt3]
Options Zone 3
[`Hbo]
Heater Bakeout Select _ _ _ _ _ _ _ _
[Min]
HBO Select Time _ _ _ _ _ _ _ _ _ _ _
[`HbC]
HBO Current Trip _ _ _ _ _ _ _ _ _ _
[`CLi]
Cur Limit Select _ _ _ _ _ _ _ _ _ _ _
[CL`A]
Cur Limit Set Point _ _ _ _ _ _ _ _ _
[tol_]
Lo Tol Set Point _ _ _ _ _ _ _ _ _ _ _
[tol–]]
Hi Tol Set Point _ _ _ _ _ _ _ _ _ _ _
[Indf]
Induct Load Factor Req _ _ _ _ _ _ _ _
[ICur]
Inductive Current _ _ _ _ _ _ _ _ _ __
[`ALr]
Alarms Configuration
[a|lgc]
Active Relay State _ _ _ _ _ _ _ _ _
[glbl]
Global Alarm _ _ _ _ _ _ _ _ _ _ _ _
[Open]
Heater Open Alarm _ _ _ _ _ _ _ _ _
[`tol]
Heater To Alarm _ _ _ _ _ _ _ _ _ _
[``OT]
Heat Sink Over Temp Alarm _ _ _
[alÇ`]
Heat Sink Over Temp Alarm Temp _
[Line]
Line Loss Alarm _ _ _ _ _ _ _ _ _ _
[p|bAl]
Phase Bal Alarm _ _ _ _ _ _ _ _ _ _
[Lbal]
Load Bal Alarm _ _ _ _ _ _ _ _ _ _
[Ldif]
Load Bal Percent _ _ _ _ _ _ _ _ _ _
[Freq]
Freq Out of Tol Alarm _ _ _ _ _ _ _
[``UC]
Volt Comp Alarm _ _ _ _ _ _ _ _ _ _ _
[``OU]
Over Volt Alarm _ _ _ _ _ _ _ _ _ _
[C|wd]
Comms Watchdog Alarm _ _ _ _ __
[COM]
Comms Configurations
[Addr]
Unit Address Select _ _ _ _ _ _ _ _ _ _
[baud]
Unit Baud Rate Select _ _ _ _ _ _ _
[`Wd]
Watchdog Select _ _ _ _ _ _ _ _ _ _ _
[`seC]
Watchdog Timeout _ _ _ _ _ _ _ _ _
[PWr]
Watchdog Fail Output Pwr Sel _ _
[rEtr]
Retransmit Configuration
[`Cf9]
Retrans Select _ _ _ _ _ _ _ _ _ _ _
[type]
Retrans Type Select _ _ _ _ _ _ _ _
[PhaS]
Retrans Phase Select _ _ _ _ _ _ _ _
[2one]
Retrans Zone Select _ _ _ _ _ _ _ _ _ _
[Cur_]
Min Amps Retrans _ _ _ _ _ _ _ _ _ _
[Cur–]
Max Amps Retrans _ _ _ _ _ _ _ _ _
[HU
A_]
Min kVA Retrans _ _ _ _ _ _ _ _ _ _
HU
A–]
Max kVA Retrans _ _ _ _ _ _ _ _ _ _
[rt|C_]
Set Retrans Output Lo Cur _ _ _ _
[rt|C–]
Set Retrans Output Hi Cur _ _ _ _
[rt|U
_]
Set Retrans Output Lo Volt _ _ _ _
[rt|U
–]
Set Retrans Output Hi Volt _ _ _ _
_ _
Factory Page
[dATA]
System Data Manipulation
[BAuP]
Backup Data Set _ _ _ _ _ _ _ _ _
[dFLt]
Default Data Set _ _ _ _ _ _ _ _ _
[rest]
Restore Data Set _ _ _ _ _ _ _ _ _
[nU
OL]
Enable NVOL Storage _ _ _ _ _ _
[`Loc]
Global/Menu Lockouts
{gLOC}
Global Lockout _ _ _ _ _ _ _ _ _ _
[`Ctr]
Control Setup Menus Lock _ _ _ _
{`Opt}
Options Setup Menus Lock _ _ _
{`Alr}
Alrms Setup Menu Lock _ _ _ _ _
{COM}
Comms Setup Menu Lock _ _ _ _
{retr}
Retrans Setup Menu Lock _ _ _ _
{`CIn}
Analog Input Menu Lock _ _ _ _ _
[C|rtr]
Retrans Menu Lock _ _ _ _ _ _ _ _
[dAtA]
Sys Data Menu Lock _ _ _ _ _ _ _
[diAg]
Diag Menu Lock _ _ _ _ _ _ _ _ _ _
[Info]
Unit Information
[`Sn–]
Unit Serial # Hi Digits _ _ _ _ _ _ _
[`Sn_]
Unit Serial # Lo Digits _ _ _ _ _ _
[date]
Mfg Date _ _ _ _ _ _ _ _ _ _ _ _ _ _
[HU
er]
Hardware Version _ _ _ _ _ _ _ _ _
[SU
Er]
Software Version _ _ _ _ _ _ _ _ _ _
[Sbld]
Software Build # _ _ _ _ _ _ _ _ _ _
[ratU
]
Unit Volt Rating _ _ _ _ _ _ _ _ _ _ _
[ratA]
Unit Curt Rating _ _ _ _ _ _ _ _ _
[2onC]
# Zones _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
[`OPt]
Installed Options _ _ _ _ _ _ _ _ _ _
[```Ç]
Heat Sink Temp _ _ _ _ _ _ _ _ _ _
[ALÇ`]
Heat Sink Alarm Temp _ _ _ _ _ _
[sdÇ`]
Safety Shutdown Temp _ _ _ _ _ _
[HIÇ`]
Hi Heat Sink Temp _ _ _ _ _ _ _ _
[HrS–]
Accum Hours _ _ _ _ _ _ _ _ _ _ _ _
[HrS_]
Accum Hours _ _ _ _ _ _ _ _ _ _ _ _
[diag]
Diagnostics
[``Ad]
Select A/D Channel _ _ _ _ _ _ _ _
[Cnts]
Read Selected A/D Counts _ _ _ _
Line Loss Alarms:
[l!a1]
Most Recent _ _ _ _ _ _ _ _ _ _ _ _
[l@a1]
Line Loss _ _ _ _ _ _ _ _ _ _ _ _
[l#a1]
Alarm Type _ _ _ _ _ _ _ _ _ _ _ _
[l!a2]
Previous
_ _ _ _ _ _ _ _ _ _ _ _
[l@a2]
Line Loss
_ _ _ _ _ _ _ _ _ _ _ _
[l#a2]
Alarm Type _ _ _ _ _ _ _ _ _ _ _ _
[l!a3]
Least Recent _ _ _ _ _ _ _ _ _ _ _ _
[l@a3]
Line Loss _ _ _ _ _ _ _ _ _ _ _ _
[l#a3]
Alarm Type _ _ _ _ _ _ _ _ _ _ _ _
[dIsp]
Display Test _ _ _ _ _ _ _ _ _ _ _ _ _
[``In]
Select Discrete Input _ _ _ _ _ _ _
[`U
AL]
Read Selected Input Value _ _ _ _
[rEtr]
Retrans Set Test Word
_ _ _ _ _ _
The Factory Page also includes calibration
parameters that are not necessary for
everyday
use of the controller. Calibration
parameters and
procedures are explained in
the Power Series
User’s manual.
Power Series Software Map
Enter your settings on a
photocopy of this page.
Содержание PC1X-F20
Страница 4: ...ii Watlow Power Series Table of Contents...
Страница 72: ......