P2T 2-Knife Trimmer
Page B-15
APPENDIX B - Uninstall the P2T
Issue 1b, June 2018
Remove the Installation Hardware from the BLM
Figure B:26. Remove the pivot location bracket from the bottom chassis rail
Pivot location bracket
Step Action
Information
1
Remove the outfeed cover.
•
Remove the 2 x M5x10 button-head
screws that fasten the top edge of the
outfeed cover to the cover mounting
bracket.
•
Lift the outfeed cover and pull toward
you.
2
Disconnect the red/violet
cable from PL5 of the 900-
227 stacker interface PCB.
•
Cut and discard the small cable tie.
•
Fit the old stacker red and white power
cable to PL4 of the 900-227 stacker
interface PCB. When installed, this
cable is stored in the accessory bag.