background image

FILTER CARTRIDGE

  

REPLACEMENT

STEP 

13

Press down on the filter cartridge so that the double O-ring 

seal moves into place within the bottom, center opening.

STEP 

16

Pull up on the Top Cap to seat o-rings.

STEP 

19

Relieve the system of air in the tank as the system fills with 

water, by pushing down on the red depressurization button 

on the top cap of the system. Keep the button pushed down 

until all the air pressure is completely released, and water 

comes out of the red depressurization button.

STEP 

22

Check for leaks.

STEP 

14

Reposition the Top Cap into its original location.

STEP 

17

 (If completed Step 2, then…) Close the 

John Guest

®

 fitting and shut-off.

STEP 

20

Release the red depressurization button.

STEP 

23

Run water through system for 

10 minutes

 before use.

STEP 

15

Reattach the top tank Snap Ring.

STEP 

18

Turn the water supply on, opening the inlet 

and outlet valves on the bypass.

STEP 

21

Replace the Umbrella cap to the top of the system.

STEP 

24

During flush, confirm green LED lights are flashing  

with flowing water. If lights are not flashing green,  

go back to step 3.

10

NO TOOLS

REQUIRED

3

2

Содержание Infinity Protector INF-PRO1

Страница 1: ...INSTALLATION OPERATION MANUAL MODEL INF PRO1 CERTIFIED WATER PROTECTION...

Страница 2: ...been designed and tested to be used on municipally treated water sources Do not use with water that is microbiologically unsafe or of unknown water quality without adequate disinfection before or aft...

Страница 3: ...TY WHERE TO INSTALL 1 CITY WATER INLET WATER METER SERVICE GROUNDED UNSWITCHED 115 VOLT OUTLET SERVICE GROUNDED UNSWITCHED 115 VOLT OUTLET WELL INLET RELIEF VALVE MUST BE INSTALLED PRESSURE TANK PUMP...

Страница 4: ...Cap 10 00 010 11 Retaining Ring 10 00 011 12 Replacement Filter INF PRO1 FX DRAIN VALVE Bypass Orientation INLET OUTLET Flow direction arrows on bypass are incorrect for this filter application Plumb...

Страница 5: ...er Assembly should be placed on the Outlet Side Note the flow direction arrow on the meter body HAND TIGHTEN ONLY STEP 4 OPTION B Use 7 90 degree Angled In Out 1 MNPT for connecting your plumbing to t...

Страница 6: ...g should slide completely out of the groove STEP 5 Remove packaging from filter cartridge then place the filter cartridge into the tank with the double O ring facing down STEP 8 Reposition the Top Cap...

Страница 7: ...Cap monitors water and flow rate and provides a visual color coded notification letting you know when the filter has reached certified capacity level at 100 000 gallons and to Replace the Filter GREEN...

Страница 8: ...oor drain or bucket and use to drain sediment or to aid in filter removal during change out STEP 5 Push down the top cap with both hands to unseat the retaining ring STEP 8 Remove old filter and disca...

Страница 9: ...r comes out of the red depressurization button STEP 22 Check for leaks STEP 14 Reposition the Top Cap into its original location STEP 17 If completed Step 2 then Close the John Guest fitting and shut...

Страница 10: ...OS 1 5 10 0 07 53 v NAME AND PART NUMBER SIZE MICRON RATING RATED CAPACITY FLOW RATE PEAK FLOW REDUCTION OF LEAD CHLORINE CHLORAMINE TASTE AND ODOR REDUCTION CAPACITY PRESSURE DROP SPEC Infinity Prote...

Страница 11: ...al attack environment accident fire flood freezing Act of God misuse misapplication neglect oxidizing agents such as chlorine ozone chloramines and other related components alteration installation or...

Страница 12: ...WaterTech 800 Freeport Pkwy 150 Coppell TX 75019 469 521 1180 CustomerSupport WaterTech com www WaterTech com...

Отзывы: