background image

CERTIFIED WATER FILTER SYSTEM

 

IMPORTANT

DO NOT USE extra lubricants, unapproved sealants and tools to tighten hand tightened 
only parts. Use of tools other than hand tighten only parts voids warranty. Testing was 
performed under standard laboratory conditions; actual performance may vary. Flush 
the system and change the filter as suggested. The contaminants or other substances 
removed or reduced by this water filter are not necessarily in all users’ water.

PERFORMANCE

Performance claims are based on independent lab results and manufacturer’s internal 
test data*. Actual performance is dependent on influent water quality, flow rates, 
system design and applications. Your results may vary. Performance claims are based 
on a complete system, including a filter, housing, and connection to a pressurized 
water source. This filter must be operated according to the system’s specifications 
in order to deliver the claimed performance. It is essential to follow operational, 
maintenance, and filter replacement requirements, as directed for each application, for 
this filter and system to perform correctly. Read the Manufacturer’s Performance Data 
Sheet accompanying the system and change the filter as suggested. The contaminants 
or other substances removed or reduced by this water filter are not necessarily in all 
users’ water.
This system has been tested for the reduction of the substances listed below. The 
concentration of the indicated substances in water entering the system was reduced 
to a concentration less than equal to the permissible limit for water leaving the system, 
as specified in NSF/ANSI 53. Minimum substance reductions are as follows:

SUBSTANCE

INFLUENT CHALLENGE 

CONCENTRATION (MG/L)

MAXIMUM PERMISSIBLE 

PRODUCT WATER  

CONCENTRATION (MG/L)

NSF/ANSI 

STANDARD

Lead

0.15 +/- 10%

0.01

53

Cyst

minimum 50,000/L

99.95%

53

PFOA/PFOS

1.5 +/- 10%

0.07

53

v

NAME AND  

PART NUMBER

SIZE &  

MICRON  

RATING

RATED CAPACITY & FLOW RATE

PEAK FLOW &  

% REDUCTION OF LEAD

CHLORINE/CHLORAMINE  

TASTE AND ODOR REDUCTION CAPACITY (*)

PRESSURE DROP 

SPEC

Infinity Protector

INF-PRO1

8” x 40” 0.5

Lead Reduction and PFOA/PFOS 

100,000 gallons @ 4.51 GPM (378,541 

Liters @ 17.1 lpm)

@ 99.62% lead reduction

@ 97.9% PFOA/PFOS reduction

8 GPM (30.2lpm) @  

99.62% reduction 

(*) >88,000 gallons at 8 GPM 

(333,116 Liters @ 30.2lpm)

>300,000 gallons @ 15 GPM  

(1,135,533 Liters @ 56.8 lpm) with greater than 

90% reduction, estimated capacity using 2ppm of 

free chlorine.

>150,000 gallons @ 8 GPM  

(567,812 Liters @ 30.3 lpm) with greater  

than 85% reduction, estmated using 3ppm  

of chloramine.

9 psid  

@ 4.51 GPM

REPLACEMENT CARTRIDGE FILTERS ARE LISTED AS Infinity Protector 0.5 Micron High Capacity Carbon Block // PART NUMBER: 

INF-PRO1-FX

*Claims are not performance tested by IAPMO or NSF. Performance claims are based on independent laboratory and manufacturer’s internal test data.

Actual performance is dependent on influent water quality, flow rates, system design and application. Results may vary.

This system is certified by IAPMO R&T against 

NSF/ANSI Standards 53 (also CSA B483.1) 

for the reduction of claims specified on the 

performance data sheet.

This pressure vessel is tested and certified  

by NSF International against NSF/ANSI 

Standard 44 and 61 for materials and 

structural integrity requirements

Electrical Requirements: Grounded & Unswitched 115 V outlet and 3-AAA Batteries 
Filter Replacement Operating Instructions: New cartridges must be flushed for a 
minimum of 10 minutes prior to use. System and installation to comply with state and 
local laws and regulations. Do not use with water that is microbiologically unsafe or 
unknown quality without adequate disinfection before or after the system. Systems 
certified for cyst reduction may be used on disinfected waters that may contain 
filterable cysts. Manufactured from NSF/ANSI standard 61 and California Prop 65 
Compliant certified coconut shell carbon and raw materials.

SPECIFICATIONS

Содержание Infinity Protector INF-PRO1

Страница 1: ...INSTALLATION OPERATION MANUAL MODEL INF PRO1 CERTIFIED WATER PROTECTION...

Страница 2: ...been designed and tested to be used on municipally treated water sources Do not use with water that is microbiologically unsafe or of unknown water quality without adequate disinfection before or aft...

Страница 3: ...TY WHERE TO INSTALL 1 CITY WATER INLET WATER METER SERVICE GROUNDED UNSWITCHED 115 VOLT OUTLET SERVICE GROUNDED UNSWITCHED 115 VOLT OUTLET WELL INLET RELIEF VALVE MUST BE INSTALLED PRESSURE TANK PUMP...

Страница 4: ...Cap 10 00 010 11 Retaining Ring 10 00 011 12 Replacement Filter INF PRO1 FX DRAIN VALVE Bypass Orientation INLET OUTLET Flow direction arrows on bypass are incorrect for this filter application Plumb...

Страница 5: ...er Assembly should be placed on the Outlet Side Note the flow direction arrow on the meter body HAND TIGHTEN ONLY STEP 4 OPTION B Use 7 90 degree Angled In Out 1 MNPT for connecting your plumbing to t...

Страница 6: ...g should slide completely out of the groove STEP 5 Remove packaging from filter cartridge then place the filter cartridge into the tank with the double O ring facing down STEP 8 Reposition the Top Cap...

Страница 7: ...Cap monitors water and flow rate and provides a visual color coded notification letting you know when the filter has reached certified capacity level at 100 000 gallons and to Replace the Filter GREEN...

Страница 8: ...oor drain or bucket and use to drain sediment or to aid in filter removal during change out STEP 5 Push down the top cap with both hands to unseat the retaining ring STEP 8 Remove old filter and disca...

Страница 9: ...r comes out of the red depressurization button STEP 22 Check for leaks STEP 14 Reposition the Top Cap into its original location STEP 17 If completed Step 2 then Close the John Guest fitting and shut...

Страница 10: ...OS 1 5 10 0 07 53 v NAME AND PART NUMBER SIZE MICRON RATING RATED CAPACITY FLOW RATE PEAK FLOW REDUCTION OF LEAD CHLORINE CHLORAMINE TASTE AND ODOR REDUCTION CAPACITY PRESSURE DROP SPEC Infinity Prote...

Страница 11: ...al attack environment accident fire flood freezing Act of God misuse misapplication neglect oxidizing agents such as chlorine ozone chloramines and other related components alteration installation or...

Страница 12: ...WaterTech 800 Freeport Pkwy 150 Coppell TX 75019 469 521 1180 CustomerSupport WaterTech com www WaterTech com...