Service Instructions / Instructional Videos
Available at www.watersoftinc.com
E.
To Service Injector , Screen, and Air Intake
1. Follow steps
A1-A2.
2. Unscrew injector cover screws and remove injector cover.
3. Remove injector screen and clean or replace.
4. Remove white injector and clean or replace.
5. Apply silicone lubricant to injector seal and replace cover and screws.
6. Unscrew air intake nut. Clean or replace duckbill assembly.
F.
To Replace Meter
1. Follow steps
A1 - A3
2. Unplug meter cable from front of circuit board.
3. Unscrew meter assembly nut from valve body.
4. Remove meter from valve body and clean or replace as necessary.
5. Reinstall meter, nut and cable.