background image

 

           

10

 

 

 

FCC ID:    

 

 

SWPLV-019 or SWPEV-019-BLE

 

 

 

Name of Grantee: 

 

CHANDLER SYSTEMS, INC.

 

 

 

Equipment Class: 

 

Part 15 Low Power Communication Device

   Notes: 

   Legacy 

View 

Valve

This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, 
and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not 
expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  NOTE: This equipment has been 
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide rea-
sonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, 
if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee 
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 

 - Reorient or relocate the receiving antenna.  
 - Increase the separation between the equipment and receiver.  
 - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
 - Consult the dealer or an experienced radio/TV technician for help. 

Status and History

From the Status and History, all items in 

ORANGE

 can be reset.

Utilizing Bluetooth Control 

1.  Start a regeneration or backwash cycle

Option 1:   

  Click the “Regenerate Unit Now.”  

  If you would  like to force the unit into the next cycle step click “Go to Next  

 

  Regeneration Step”.

Option 2:  

“Regenerate Unit at Next Regen Time” button. 

Touch any table to explode
a detailed list of the last 60 
days. 

This will take the system into a backwash cycle at the next regeneration time.

Содержание ISOBAR II

Страница 1: ...Installation Operation Manual...

Страница 2: ...ammingtheControlValve Page 11 Master Programming Mode Page 14 Control Valve Powerhead Assy ISO II ISO III Page 15 Valve Body Assembly ISO II Page 16 Bypass Assembly ISO II Page 17 Valve Body Assembly...

Страница 3: ...art LT 150 Sealants Pipe dope and liquid thread sealers may contain a carrier that attacks some plastic materials It is recommended that Teflon tape be used to seal plastic Noryl threaded fittings Gen...

Страница 4: ...g required for filter connection e g copper galvanized PVC plastic Note If household plumbing is galvanized and you intend to make the installation with copper or vice versa obtain di electric unions...

Страница 5: ...istributor tube to prevent material from entering tube while filling C Place media funnel in hole on top of tank D Pour several gallons of water in the tank Fill tank about 1 3 full E Pour in the requ...

Страница 6: ...out on housing Note When re installing the drain line flow control housing be sure you hear and feel the O Ring pop into place before inserting the clip 2 Install 1 2 I D drain line tubing not include...

Страница 7: ...nections have been made turn main water supply back on and check for leaks 2 Ensure that the bypass valve is in the BYPASS position and then cycle the control valve to RAPID RINSE Once the rapid rinse...

Страница 8: ...he default password the first time you connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 3 BTLE Valve de...

Страница 9: ...me This sets the amount of days between backwash cycles Example For 2am just type 2 and press OK Advanced Settings NOTE Consult your dealer before making any changes We do not recommend changing Advan...

Страница 10: ...uctions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interfer...

Страница 11: ...eft digit Backwash will begin at the set Backwash Time A 0 setting will cancel this feature The Max Value for this item is 29 Example Backwash every 7 days A 07 Factory Setting Cancel setting A 00 To...

Страница 12: ...inish the cycle where it left off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position and then res...

Страница 13: ...it is moving towards The default time at which regeneration will occur is 12 00 a m The motor s run direction during a particular regeneration cycle step is indicated by the rotation direction of the...

Страница 14: ...Times Centuri Steps 2 3 4 5 Example 3 20 The next 4 displays set the duration of time in minutes for each backwash cycle step The step number which is currently modifiable is indicated on the far lef...

Страница 15: ...Power Supply 20001X125 1 7 Back Plate 20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Motor 20016X006 1 10 Switch Spacer 20111X004 1 11 Slide Cover 20111X001 1 12 Motor Screw SC2 4 13 Screw SC9...

Страница 16: ...arb 20017X235 1 8 Drain Retainer Clip 20017X214 1 9 Brine Valve Plug O Ring 20001X230 1 10 Centuri Air Intake Check Valve 20944C250 1 11 10 24 X 1 Hex Screw 20001X226 2 12 Injector Cover 20001X223 1 1...

Страница 17: ...17 Bypass Assembly Ref Description Part Qty 1 Plastic Bypass Valve Assembly 20561X292 1 2 Bypass Valve 3 4 Stainless Steel 20561X270 1 Bypass Valve 1 Stainless Steel 20561X283 1 1 2...

Страница 18: ...18 Valve Body Drive Assy...

Страница 19: ...ssy 20009X228 1 11 Brine Line Ferrule 20251X305 1 12 Plug 20009X005 1 13 10 24 X 1 Hex Screw 20001X226 2 14 3 8 Push Lock Plug 20009X010 1 15 Injector Cover 360 20009X001 1 16 Injector Seal 20001X224...

Страница 20: ...283 2 1 Female Straight Slip Set optional 20017X288 3 1 NPT Elbow Set 20017X284 4 1 NPT Straight Set optional 20017X289 5a Elbow Vertical Adapter Blank optional 20017X295 5b Elbow Vertical Adapter 1 4...

Страница 21: ...cover C To Replace Piston Assembly 1 Follow steps A1 A3 2 Disconnect the meter signal wire from the circuit board 3 Remove lower back base screws and detach lower back base 4 Remove screw and washer a...

Страница 22: ...nd clean or replace 4 Remove white injector and clean or replace 5 Apply silicone lubricant to injector seal and replace cover and screws 6 Unscrew air intake nut Clean or replace duckbill assembly F...

Страница 23: ...quently Increase number of minutes in air draw cycle Clean injection assembly and screen instructions on page 11 4 Loss of Water Pressure Scaling fouling of inlet pipe Clean or replace pipline Pretrea...

Страница 24: ...cle power to clear the error code Manually cycle the powerhead through the regeneration cycle steps to verify that the motor can cycle properly while the powerhead is disconnected from the valve body...

Страница 25: ...25 Warranty...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...28 710 Orange Street Ashland OH 44805 PH 419 289 1500 FAX 419 289 1515 www watersoftinc com 3 2018...