39
|
46
Enabling the High-Pressure Discharge—Pressure Mode Controller
1
2
Use the illustrations and instructions to enable the
high-pressure discharge.
Note:
Make sure that you set the engine to idle
before you engage the high-pressure
discharge to avoid activating the external
pressure relief valve or the speed governor
system.
1 Enable the high-pressure discharge by pressing
the
High
side of the switch. The amber LED
flashes as the cylinder traverses between
modes and illuminates solid once the mode is
achieved.
2 Disable the high-pressure discharge by
pressing the
Low
side of the switch. The green
LED flashes as the cylinder traverses between
modes and illuminates solid once the mode is
achieved.
After operation, follow established procedures that
include:
•
Do not store the pump partially full. Completely
fill, or drain, the pump before storage.
•
Always drain the pump when freezing can occur.
NOTICE
Do not allow fluid in the
lines to freeze.
•
Remove all freezable fluid
from the lines before
storing the apparatus.
•
Freeze Damage
•
Disable the pump drive when placing the
apparatus into storage.