Operating Limits
Every application has operating limits. Do not exceed the maximum pressure or
speed listed below during operation.
Maximum pressure
• Low-pressure mode—250 psi (17 bar)
• High-pressure mode—600 psi (43 bar)
Maximum speed
• Low-pressure mode—3950 rpm
• High-pressure mode—3450 rpm
Operating the pump beyond specified limits causes accelerated wear on
components such as seals, bearings, and other parts—this can cause
premature component failure.
NOTICE
•Premature component
failure occurs when
operating beyond
system specifications.
•Do not operate the system
beyond specifications.
Premature Failure
Operating the system beyond the operating limits or system specifications will
void your warranty.
Operating the pump beyond recommended maximum pressure can causes
liquid to eject at high pressure—this can cause injury to the operator and/or
bystanders.
Do not operate beyond
recommended pressure.
Liquid ejected at high
pressure can cause
serious injury.
High Pressure
•
•
Operating the system beyond the operating limits or system specifications will
void your warranty.