F-1031, Section 4212
Page 47 of 61
Rotary Style - Bottom Mounted Electric Transfer Valve Actuator Removal/Installation (After 2000)
1. If possible, rotate the transfer valve to the
VOLUME position before removal.
2. If transfer valve actuator is equipped with
optional manual override, remove this first
by removing spirol pin, 1/8 x 3/4, from
U-joint. Then slide entire assembly out
from gear motor shaft.
3. Remove transfer valve actuator assembly
by removing socket head screws, 5/16-18
x 5/8 and (3) lock washers, 5/16 and (3)
lock washers, 5/16.
4. Extension shaft may come loose from
transfer valve actuator. Make sure key,
3/16 x 1-1/4 (3/16 x 3/4 on actuators built
prior to 4/21/06), is in place when
reinstal•
ling extension shaft. This will insure proper
alignment.
5. For repair of the transfer valve actuator
subassembly, refer to form F-1031,
Sec•
tion 2315,
Transfer Valve Overhaul
Encoder Ground
Wire Location
Prior to 1/7/08
Stamped Arrow
(Under Mounting Bracket)
Gear Motor
Shaft
Encoder Ground
Wire Location
After 1/7/08
Lock Washer, 5/16
Socket Head Screw
5/16-18 x 5/8
Spirol Pin
,
1/8 x 3/4
U-joint
Instructions
.
6. When reinstalling transfer valve actuator,
make sure extension shaft is turned to the
volume position. To find out if actuator is in
the volume position, check under
mounting bracket for a stamped arrow with
the letter
“V” for volume. The arrow indi-
cates the direction in which the extension
shaft must be fully rotated to be in volume
position. Turn opposite way to be in
pres•
sure position. Pump mode should also be
in volume position to ensure that
exten•
sion shaft and groove pin from transfer
valve ball will properly align when
reinstal•
ling actuator to pump. Use alignment
marks as shown on attached page,
“Bot
tom View of Transfer Valve Ball in Volume
Position.”
NOTE: The gear motor shaft must be
used to turn the extension shaft.
Key
, 3/16 x 1-1/4
Mounting Bracket
Extension Shaft
Groove Pin
IL1972