5. Sound Emissions. 
 

The 

RainsaverMK4E 

is virtually silent but may emit noises associated with the flow of water through 

the unit.  
 
In any case, the pump, which is connected to the 

RainsaverMK4E

, may emit sound levels, which 

may inconvenience you or your neighbours, or may operate during normal sleeping hours, which may 
be prohibited by local government regulations. If this is the case, your 

RainsaverMK3

 can be 

switched off during the night or may be operated from a time clock. Your 

RainsaverMK4E 

will 

automatically supply your house with Mains water supply while the pump is inactive. 
 
 

6. Maintenance. 

 
Ensure that water flowing through the 

Rainsaver MK4E 

is as free from dirt and foreign matter as 

conditions allow. 
 
Ease of accessibility will aid any maintenance and reduce any servicing costs if required. 
 
Periodically inspect the rainwater tank inlet strainer and the first flush device. Periodically inspect 
filters downstream and strainers if fitted upstream from the 

Bianco Rainsaver MK4E

 every 6 months 

depending on water quality and usage. 

 

Operate the Rainsaver on mains regularly or at least once a month by turning the power off to the 

RainsaverMK4E.

 

 

7. Trouble shooting. 

 
Consult the manuals supplied with the water pump and its controller if fitted in addition to the 
following guide. 
 

1. 

Mains flow is not available or low when Pump is switched off or not operating. 
a.  Isolation valve, if fitted, is not open. 
b.  Debris has jammed the mains inlet check valve closed. 
c.  External Inlet strainer / filter, if fitted, are blocked. 

 

2. 

Pump flow is not available or low when pump is operating through Bianco Rainsaver 
MK4E. 
a.  Pump has lost its prime. 
b.  Isolation valve, if fitted, is not open. 
c.  Debris has jammed the pump inlet check valve closed, or has blocked the check 

valve. 

d.  External Inlet strainer / filter, if fitted, is blocked. 

 

3. 

Pump does not start. 
a.  Rainwater tank is empty. 
b.  Power supply is off. 
c.  Float switch is not installed correctly. 
d.  Pump controller is not installed correctly or jammed with debris. 
e.  Pump has a fault. 

 

4. 

Pump does not stop. 
a.  Leak in plumbing. 
b.  Pump controller is not installed correctly or jammed with debris  
c.  Float switch is not installed correctly. 

 
Note* 

Should there be a pump failure, mains back up is achieved by turning the 

RainsaverMK4E 

off at 

the power point. 
 
For after sales service please contact White International Customer Service: 1300 783 601

 

Содержание rainsaver Bianco RainsaverMK4E

Страница 1: ...Bianco RainsaverMK4E Installation and Operating Instructions Bianco RainsaverMK4E is WaterMark Level 1 approved to ATS5200 477 2006 Certificate No 23022 and incorporates internal dual check valve back flow prevention for the mains water ...

Страница 2: ...turning the RainsaverMK4E off at the power point The low voltage float switch supplied prevents the pump from running dry and allows automatic switch over to mains supply should the rain water level in the tank be too low 4 Installation 4 1 Pump Float Switch installation The 10m 12V DC low voltage float switch supplied prevents the pump from running dry and allows automatic switch over to mains su...

Страница 3: ...ge pressure should be 65 of pump maximum pressure Wall Mounting Instructions To reverse the mounting direction so that Mains inlet will be on the left side and House outlet on the right follow the first steps of Pump Mounting Instructions below to remove and reverse the mounting bracket Then continue Remove the RainsaverMK4E lid by unscrewing the 4 Phillips head screws Hold the RainsaverMK4E in th...

Страница 4: ...e housing This will stop insects creating a nest inside the Rainsaver Unit Replace the lower union nut and pipe being sure that internal components are in place and that the o ring is properly seated Leave the lower union nut slightly loose to allow fitting and alignment to pump Attach the BSPT male pipe fitting to the pump outlet either directly or using plastic threaded pipe fittings as required...

Страница 5: ...n x F I elbow fitting to connect between copper tubing and BSPT threaded pipe fitting at the MAINS inlet PUMP INLET if unit is wall mounted and HOUSE outlets Use standard BSP female threaded fittings to connect to BSPT threaded pipe fitting when connecting other types of piping DO NOT REMOVE THE UNION NUT AND BSPT PIPE FITTING AND ATTEMPT TO CONNECT PIPE WORK DIRECTLY TO THE BODY OF THE UNIT DO NO...

Страница 6: ...urer s instructions regarding pressurization of your pressure tank 4 7 Pressure Tank Pre charge To ensure optimum performance and system life the Pressure Tank pre charge needs to be set by filling the pressure tank with air through the air valve so that the air pressure is 65 of the pump maximum pressure Pre charge the pressure tank before it is installed by using an air pump or using the local s...

Страница 7: ...mains regularly or at least once a month by turning the power off to the RainsaverMK4E 7 Trouble shooting Consult the manuals supplied with the water pump and its controller if fitted in addition to the following guide 1 Mains flow is not available or low when Pump is switched off or not operating a Isolation valve if fitted is not open b Debris has jammed the mains inlet check valve closed c Exte...

Страница 8: ...tands high inlets floating suction hose kits assist in the pumping cleaner water that is found at higher levels in the rainwater tank See pump installation accessories on page 13 9 Water Tanks Water borne algae and roof litter can accumulate at the bottom of your rainwater tank that can be sucked up by your pump To reduce filter blockages we recommend that suction outlets on rainwater tanks be 100...

Страница 9: ...INSTRS110110 rev 6 01 03 15 Page 9 Installation Dimensions ...

Страница 10: ...INSTRS110110 rev 6 01 03 15 Page 10 Typical Installations DAB or BIANCO surface mounted pumps RAINSAVER MK4E RAINSAVER MK4E ...

Страница 11: ...INSTRS110110 rev 6 01 03 15 Page 11 TESLA DIVERxxxMPCX Submersible Pump RAINSAVER MK4E RAINSAVER MK4E ...

Страница 12: ...INSTRS110110 rev 6 01 03 15 Page 12 BIANCO JH8003PMPCX or B42A Submersible Pumps RAINSAVER MK4E RAINSAVER MK4E ...

Страница 13: ...INSTRS110110 rev 6 01 03 15 Page 13 DAB DIVERTRON1200 Submersible Pump RAINSAVER MK4E RAINSAVER MK4E ...

Страница 14: ...p Cover protects pump from the elements Pump stand for submersible pumps lifts pump up to pump cleaner water DAB Divertron X conversion kit allows pumping from higher level and connection to floating suction kits to pump cleaner water higher in the tank ...

Страница 15: ... conversion kit allows pumping from higher level and connection to floating suction kits to pump cleaner water Floating suction hose kits allow pumping from cleaner water higher in the tank Float switch for bladder tank Piggy back float switch option for Divertron ...

Страница 16: ...INSTRS110110 rev 6 01 03 15 Page 16 ...

Отзывы: