4.4 Filtration and Water Quality 

 
The 

Bianco  Rainsaver  MK4E

  is  designed  to  operate  on 

clean 

rainwater  and  clean  mains  water 

supply, and as such, the rainwater tank should be fitted with an inlet strainer, preferably shaded type 
to reduce algae, and a suitable first flush device. 
 
White International strongly recommends the use of a strainer or filter upstream with easy access for 
period cleaning from both the rainwater and mains inlet connections of the 

Bianco Rainsaver MK4E

.  

 
Additional  water  filters  may  be  required.  Also  check  the  water  tank  and  first  flush  diverter  as  per 

manufacturers’ instructions regarding periodic servicing that is required. 

 

 
Filters need to be checked regularly as reduced flow caused by blocked filters can damage pumping 
equipment. 
 
 

4.5 Plumbing 

 

Plumbing connections should be carried out by a licensed plumber. 

 
Use  of  flexible  pipe  connections  and  isolation  vales  is  recommended  to  assist  in  alignment  and 
servicing and to reduce any transmitted noise. 
 
Use a standard 

¾” compression 

x F.I. union or Compression x F.I. elbow fitting to connect between 

¾” copper tubing  and  ¾” BSPT threaded 

pipe  fitting 

at the “MAINS” inlet, “PUMP

  INLET

  (if  unit  is 

wall mounted)

, and “HOUSE” outlets.

 

 

Use  standard  ¾”  BSP  female  threaded  fittings  to  connect  to  ¾”  BSPT  threaded

  pipe  fitting  when 

connecting other types of piping. 
 
DO 

NOT

 

REMOVE THE UNION NUT AND ¾” BSPT PIPE FITTING AND ATTEM

PT TO CONNECT 

PIPE WORK DIRECTLY TO THE BODY OF THE UNIT! 
 
DO 

NOT

  ATTEMPT  TO  CONNECT  COPPER  OR  PLASTIC  PIPE,  USING  COPPER  OR  NYLON 

OLIVES, A

ND COMPRESSION NUT DIRECTLY TO THE ¾” BSPT PIPE FITTING!

 

 
Always use the spanner provided, or correct open ended spanner, when tightening fittings.  
 

All pipe-work and outlet fittings from the RainsaverMK4E must be labelled to AS3500. 

 
The

  RainsaverMK4E

  control  incorporates  a  dual  check  valve  to  prevent  cross  connection  between 

mains and rainwater. Connection to an underground rain water tank, or local water supply authorities, 
may  require  additional,  or  higher  safety  level,  back  flow  prevention,  and  your  licensed  plumber  can 
advise you on this. 
 
The incorporation of an additional 

Tee

 fitting between the tank water pressure pump supply, and the 

RainsaverMK4E 

lower 

“PUMP  INLET”

,  will  allow  the  householder  to  use  collected  rainwater,  but 

NOT mains water supply, to irrigate gardens and lawns, or wash cars.    
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание rainsaver Bianco RainsaverMK4E

Страница 1: ...Bianco RainsaverMK4E Installation and Operating Instructions Bianco RainsaverMK4E is WaterMark Level 1 approved to ATS5200 477 2006 Certificate No 23022 and incorporates internal dual check valve back flow prevention for the mains water ...

Страница 2: ...turning the RainsaverMK4E off at the power point The low voltage float switch supplied prevents the pump from running dry and allows automatic switch over to mains supply should the rain water level in the tank be too low 4 Installation 4 1 Pump Float Switch installation The 10m 12V DC low voltage float switch supplied prevents the pump from running dry and allows automatic switch over to mains su...

Страница 3: ...ge pressure should be 65 of pump maximum pressure Wall Mounting Instructions To reverse the mounting direction so that Mains inlet will be on the left side and House outlet on the right follow the first steps of Pump Mounting Instructions below to remove and reverse the mounting bracket Then continue Remove the RainsaverMK4E lid by unscrewing the 4 Phillips head screws Hold the RainsaverMK4E in th...

Страница 4: ...e housing This will stop insects creating a nest inside the Rainsaver Unit Replace the lower union nut and pipe being sure that internal components are in place and that the o ring is properly seated Leave the lower union nut slightly loose to allow fitting and alignment to pump Attach the BSPT male pipe fitting to the pump outlet either directly or using plastic threaded pipe fittings as required...

Страница 5: ...n x F I elbow fitting to connect between copper tubing and BSPT threaded pipe fitting at the MAINS inlet PUMP INLET if unit is wall mounted and HOUSE outlets Use standard BSP female threaded fittings to connect to BSPT threaded pipe fitting when connecting other types of piping DO NOT REMOVE THE UNION NUT AND BSPT PIPE FITTING AND ATTEMPT TO CONNECT PIPE WORK DIRECTLY TO THE BODY OF THE UNIT DO NO...

Страница 6: ...urer s instructions regarding pressurization of your pressure tank 4 7 Pressure Tank Pre charge To ensure optimum performance and system life the Pressure Tank pre charge needs to be set by filling the pressure tank with air through the air valve so that the air pressure is 65 of the pump maximum pressure Pre charge the pressure tank before it is installed by using an air pump or using the local s...

Страница 7: ...mains regularly or at least once a month by turning the power off to the RainsaverMK4E 7 Trouble shooting Consult the manuals supplied with the water pump and its controller if fitted in addition to the following guide 1 Mains flow is not available or low when Pump is switched off or not operating a Isolation valve if fitted is not open b Debris has jammed the mains inlet check valve closed c Exte...

Страница 8: ...tands high inlets floating suction hose kits assist in the pumping cleaner water that is found at higher levels in the rainwater tank See pump installation accessories on page 13 9 Water Tanks Water borne algae and roof litter can accumulate at the bottom of your rainwater tank that can be sucked up by your pump To reduce filter blockages we recommend that suction outlets on rainwater tanks be 100...

Страница 9: ...INSTRS110110 rev 6 01 03 15 Page 9 Installation Dimensions ...

Страница 10: ...INSTRS110110 rev 6 01 03 15 Page 10 Typical Installations DAB or BIANCO surface mounted pumps RAINSAVER MK4E RAINSAVER MK4E ...

Страница 11: ...INSTRS110110 rev 6 01 03 15 Page 11 TESLA DIVERxxxMPCX Submersible Pump RAINSAVER MK4E RAINSAVER MK4E ...

Страница 12: ...INSTRS110110 rev 6 01 03 15 Page 12 BIANCO JH8003PMPCX or B42A Submersible Pumps RAINSAVER MK4E RAINSAVER MK4E ...

Страница 13: ...INSTRS110110 rev 6 01 03 15 Page 13 DAB DIVERTRON1200 Submersible Pump RAINSAVER MK4E RAINSAVER MK4E ...

Страница 14: ...p Cover protects pump from the elements Pump stand for submersible pumps lifts pump up to pump cleaner water DAB Divertron X conversion kit allows pumping from higher level and connection to floating suction kits to pump cleaner water higher in the tank ...

Страница 15: ... conversion kit allows pumping from higher level and connection to floating suction kits to pump cleaner water Floating suction hose kits allow pumping from cleaner water higher in the tank Float switch for bladder tank Piggy back float switch option for Divertron ...

Страница 16: ...INSTRS110110 rev 6 01 03 15 Page 16 ...

Отзывы: