1. Isolate water supply and relieve pressure by opening a downstream tap.
2. Cut pipe to suit length of required valve and housing installation.
3. Use approved brass, galv/poly plumbing fittings to suit existing pipework. The
female threads on the housing will receive tapered male threads. Thread into
housing head carefully as too much tape or overtightening may cause it to split.
Warning: Use PTFE thread seal tape on all connections. Use of pipe
sealants will void warranty.
4. If using sweated fittings, allow enough time to cool before connecting to the
housing.
5. Securely fix wall mount bracket and pipework with suitable clips. Allow 50mm
clearance underbowl for filter changes.
6. Flush debris from pipework.
7. Install filter cartridge as per cartridge replacement instructions (pg.5).
Typical Installation
1
3
2
4
5
6
1
Inlet (not included)
2
Connecting Pipework (not included)
3
Isolation Valve (not included)
4
Pressure Limiting Valve (not included)
5
Backflow Prevention Valve (not included)
6
Mount Bracket and Screws (single housing pictured)