FAULT CODES
UV LED Blinking – UV Error
Possible Reason
Solution
UV Lamp or Pump is Not
Operational
Check Connections to UV Lamp / Pump Assembly. Replace
UV Lamp / Pump Assembly as needed.
Heating and Service LED Blink Simultaneously – Hot Water Sensor Error
Possible Reason
Solution
Sensor not connected or is not
operating within set
parameters
1.
Check connection to Hot water sensor.
2.
Check OHMS reading – above 900K indicates open
sensor. Below 5.2K indicates sensor short.
Replace Hot Water Sensor
Chilling and Service LED Light Blink Simultaneously – Cold Water Sensor Error
Possible Reason
Solution
Sensor is not connected or is
not operating within set
parameters
1.
Check connection to Cold Water Sensor.
2.
Check OHMS reading – above 690K Indicates Open
Sensor, below 7.3K indicates Sensor Short.
Replace Cold Water Sensor.
Heating and Service LED Alternate Blinking –Low Water Level Error
Possible Reason
Solution
Full level sensor has detected
water, but low level is not
detected
Check connection to low water level sensor.
Replace low water level sensor
WL800
Operating, Installation, and Service Manual Page 64 - Revision: 5-14-2015
Содержание WL800 - MAX II
Страница 45: ...WL800 EXPLODED VIEW AND PARTS LIST WL800 Operating Installation and Service Manual Page 45 Revision 5 14 2015...
Страница 53: ...CABLE SPECIFICATIONS WL800 Operating Installation and Service Manual Page 53 Revision 5 14 2015...
Страница 54: ...WL800 Operating Installation and Service Manual Page 54 Revision 5 14 2015...
Страница 55: ...WL800 Operating Installation and Service Manual Page 55 Revision 5 14 2015...
Страница 56: ...WL800 CIRCUIT DIAGRAMS MAIN PBA WL800 Operating Installation and Service Manual Page 56 Revision 5 14 2015...
Страница 57: ...WL800 Operating Installation and Service Manual Page 57 Revision 5 14 2015...
Страница 58: ...FRONT PBA WL800 Operating Installation and Service Manual Page 58 Revision 5 14 2015...
Страница 59: ...PBA LOCATION DIAGRAM MAIN PBA WL800 Operating Installation and Service Manual Page 59 Revision 5 14 2015...
Страница 60: ...WL800 Operating Installation and Service Manual Page 60 Revision 5 14 2015...
Страница 61: ...WL800 Operating Installation and Service Manual Page 61 Revision 5 14 2015...
Страница 62: ...SMPS WL800 Operating Installation and Service Manual Page 62 Revision 5 14 2015...
Страница 63: ...SMPS WL800 Operating Installation and Service Manual Page 63 Revision 5 14 2015...
Страница 66: ...TROUBLESHOOTING POWER SUPPLY FAULT WL800 Operating Installation and Service Manual Page 66 Revision 5 14 2015...