Revision 1.1
Page 25
Pre-installation and sanitization procedures as prescribed in this manual must be performed
before installing the
WL500
.
Always install indoors and place the
Waterlogic WL500
on a firm, flat and stable surface.
Attach the water supply line to the 1/4” feed water inlet bulkhead fitting on the back of the
unit.
Waterlogic
requires the use of a water pressure regulator. Water feed pressure must be
between 40-60 psi. Turn on the water supply and check for leaks.
1.
Check to ensure that both the red and green power switches are in the O=OFF position.
NOTE:
Switches have internal LED that illuminates when placed in I=ON position.
2.
Connect the power cord to the back of the
Waterlogic WL500
and to a 120 Volt supply.
3.
Turn the Red Power Switch to I=ON position.
CAUTION!
NEVER TURN ON HEATER BEFORE FILLING HOT TANK.
Green Compressor/Heater Switch must be in the O=OFF position while the hot tank is empty.
Damage could occur within one minute and the overload (high limit) will require manual
reset if heater is turned on with an empty hot tank.
4.
Prime the Cold Circuit. Holding a container under the dispensing faucet, press and hold the
main dispensing button until a continuous flow of water is obtained. Once a continuous
flow is obtained, release the dispensing button. Cold tanks are now full.
5.
Prime the Hot Tank. Holding a container under the dispensing faucet, press the hot button
(Button 3) followed by the main dispensing button until a continuous flow of water is
obtained. Once a continuous flow is obtained, release the main dispensing button. Hot
tank is now full.
6.
Prime the Sparkling Circuit. Holding a container under the dispensing faucet, press the
sparkling button (Button 2) followed by the main dispensing button until all water is
dispensed and a continuous flow of gas is obtained. Once a continuous flow of gas is
obtained, release the main dispensing button and the Sparkling tank will regenerate itself.
7.
Verify that the UV lamp operates as expected (no alarm annunciated on the display).
WARNING!
ULTRAVIOLET RADIATION.
Protect your skin and eyes against ultraviolet
rays. Never look directly at an operating UV light. Always disconnect before removal.
8.
Press the cold button and dispense cold water into the drip tray to test the alarm. Ensure
that the drip tray alarm will sounds for 15 seconds, Drip Tray Fault is present on the LCD
display, and the unit cuts off water supply. Empty the drip tray and wipe dry. While the
drip tray is unattached from the front panel dry the alarm sensor connectors. Carefully
install drip tray to avoid damage to the metal sensor clips. Do not jam drip tray back into
the unit and make sure it is properly seated.
9.
Move the
Waterlogic WL500
into its final operating position. Be sure that a minimum of 2”
clearance is maintained around both the sides and the back of the unit. This is important to
allow proper airflow and heat exchange of refrigeration system.