Revision 1.1
Page 24
INSTALLATION PROCEDURES
Safety and Installation Guidelines
Ensure all Local, State, and Federal Laws and Codes including health and safety guidelines are
met when installing
Waterlogic
Equipment. Only qualified service technicians should attempt
installation and service of
Waterlogic
Equipment.
WARNING!
ELECTRICAL SHOCK HAZARD.
Always unplug (isolate from power supply) to
prevent electrical shock except where electrical tests are specified.
WARNING!
IMPROPER SUPPLY OR CONNECTION CAN RESULT IS RISK OF SHOCK.
Connect to a 15 amp 120V 60Hz properly grounded outlet (GFI is recommended). Ensure
polarity is correct and always use a 3-prong outlet. Consult a qualified electrician if you have
any questions.
WARNING!
USE ONLY Waterlogic SUPPLIED POWER CORD (EL-5001-A).
Locate system
within 5 feet of power supply. Never use an extension cord or adapter. Do not use a damaged
power cord or plug. Keep power cord out of heavy traffic areas and away from heat sources.
Do not, under any circumstances, remove ground prong or alter the power cord. Never pull the
power plug from the outlet with a wet hand or allow the plug to get wet. Failure to use the
supplied power cord will void UL Certification and Warranty.
CAUTION!
INDOOR USE ONLY
.
Never exposed to direct sunlight, heat sources, or ambient
air temperature above 97F (36C) or below 50F (10C). Install indoors and keep unit away from
excessive humidity. Never expose to freezing temperatures. Ensure there is adequate clearance
around the unit to allow refrigeration system condenser to dissipate heat. Warmer
environments require more clearance around the unit. Minimum clearance around all surfaces
of the machine is 2-inches. Installs where the ambient temperature exceed 80F, require a
minimum of 4-inches clearance for proper heat dissipation and efficient operation.
CAUTION!
USE A WATER PRESSURE REGULATOR. Waterlogic
will not be responsible for
injury or damage caused by excessive water pressure. Operating pressure must be 40 psi to 60
psi. Be aware any of potential pressure surges caused by building/municipal pumping stations.
CAUTION!
USE UV STABLIIZED SUPPLY LINES.
Feed the unit with a potable ambient or cold
water supply only.
Feed water over 105 F (40C) can damage the treatment components. Water
block devices and external leak detectors are strongly recommended. Locate the unit as close to
the water supply and the electrical connections as possible.
WARNING!
HIGH PRESSURE CO2 GAS.
Use/Handle in accordance with all safety standards.
WARNING!
STORE UNIT EMPTY
.
ALWAYS SANITIZE BEFORE USE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Sanitize before use to eliminate any
potential microbiological contaminates
WL500
can be combined with RO Filtration Systems. RO will require a drain connection. Refer
to all applicable plumbing codes and standards in your area for these requirements (air gap
connections and back flow prevention may be necessary).
Содержание WL500 - Sparkling
Страница 11: ...Revision 1 1 Page 11 WL500 FLOW DIAGRAM...
Страница 30: ...Revision 1 1 Page 30 WL500 MAIN PARTS DRAWING...
Страница 33: ...Revision 1 1 Page 33 WL500 WETTED PARTS DRAWING...